Document yGa3jB06ryqaqX19NOexoGR3
COMPLAINT INVESTIGATION ' ` OROANlC CHEMICALS DIVISION
bllTRICT
DAT!
TIM*
COMPLAINT NO.
r*COUNM'i>A.................................
10/2/62
NAME 4 LOCATION
TOi Mr. W. E. Ault - 0. 0.
PRODUCT
Aroclor 1254
CUITOMtR
Shipped To ttremco Manufacturing Co,
Complaint No. 32-K-62
nn quality ZZ SKRVICK
COMPLAINT
TYP* OF COMPLAINT
Quality
At Cleveland, Ohio
Mj *HIPP*R` NO,
ill SN
DAT* HIPP*D
Not Avail.
LOT NO.
.
. KB-603
QUANTITY
For
| 2-00-730.01
CO Messrs. > R. E. Soden E. E, Mart d nWff. Sml th 0. K, QJbson-B2S H. S. Bergeri-P?S H. 0. Hehner-B?N W. J. Gresham
PINDINOI
Through a packaging error in January, Aroclor 1248 was filled into 1254 drums and improperly stencilled 1254. When this error was detected in June through Complaint 19-K-62,all Krummrich stocks were checked. We had no record of any material being transferred to branch warehouses.
The sample returned from Tremco was Aroclor 1248 not 1254. This was
indicated by identification by Refractive Index. Material was shipped from Cleveland Warehouse and was not, therefore, retrieved before.
CONCLUIIONI
Pi NORMAL IN ALL RKIPBCTI
MEET* EPBCIFICATION* BUT OUTIIDB NORMAL RANO*
DOt, NOT MEET tPECIPICATIONI
|-| tURJECTIVE RRORRATIR, INVOLVED
DBT BRIORATED IN ITORAOB
5 JUITIRIED NOT JUITIPIBD
AICOMMENDATIONI
P~1 HAVB MATERIAL RETURNED
ATTEMPT TO 08T CUSTOMER
TO KEEP EKIPMBNT CONNECTIVE ACTION TAKEN
OTHER URECirvI
0186045
(23 OTHER (tRECIPV)
All containers of lot KB-603 should be returned.
We Will inventory our warehouse again to be sure no material from KB-603 is on hand.
Our Shipping Department will check all orders for 1962 and list all ship ments of lot KB-603. Mr. Ault will notify all Branch Warehouses of the problem and determine if any of this lot is on hand. We will then arrange to have any material still on hand either analyzed or returned.
DMi'vV..
1NVEITI0 AT*D *Y
E. E. Martin
P. E, Heisler
QAT* ,
R. E. Soden
10/2/62
TOWOLDMONOQ54027