Document y09aLNaBMwQ9oj7GxO14MNV4
INTERNAL CORRESPONDENCE
UNION CARBIDE CORPORATION TECHNICAL CENTER
PQ BOX Q3B1, SOUTH CHARLESTON, WV 25303
I o INfimel Oi,,i&Kjn
H. E. Rucker 512/2009
Ar ea
ClJpy IT)
B. H. Avashia, M.D. - 512/23 J. W. Barna - 2009/6 W. L. Browning - 2009 W. V. Filipek - 5515 C. P. Maxwell - 701/2 B. R. McMakin - 2009 0. H. Parsons - 2281 W. 0. Vincent - 514/109
"i, n.-t-,L
March 19, 1987 EH&TS _
Ar,il Industrial Hygiene Asbestos Exposure Monitoring
Attached are the results of the Asbestos exposure monitoring performed on insulators in the South Charleston Plant, Building 706. They were monitored over a 3 day period while using glove bags to remove asbestos from several lines, horizontal and vertical.
Employees were equipped with 2 pair of coveralls, no street clothes, boots, gloves, head cover and either an A0R57A or Willson R12 Half-face, HEPA filter, respirator. The employees showered each day, before leaving the plant.
The monitoring results indicate that the exposure levels were well below the 0.1 fiber/cc Action Level, established by OSHA for an 8-hour workday (TWA8). We feel that the glove bag method is a very good way of controlling airborne fibers. However, we must be sure that the procedure is followed closely by each insulator using a Glove Bag.
Please inform J. R. Chandler, R. E. Coyner and 5. M. Barker of their exposure monitoring results, as soon as possible. Have them sign and date this report and return to M. A. Patel at Building 701-330.
UCC 024578
Asbestos Exposure Monitoring
-2-
March 19, 1987
If you have any questions or if we can be of further assistance, please feel free to call us on extension 4779 or 3750.
WORK BY:
APPROVED BY:
Vance E. Stover
Attachment
VES:MAP:rab 2180P
Manhar A. Patel
UCC 024579
ASBESTOS EXPOSURE MONITORING
Carp. Ref. W2158 W2160 W2161
Date 3-11-87 3-12-87 3-12-87 3-12-87 3-13-87
Sample Type/ Enployee Name
Sarrpling Time
Personal/ J. R. Chandler
6hrs 57mirt
Air Cone, fibers/cc
0.0314
Wq fibers/cc
0.0273
COM-ENTS
Collected while stripping, along with 2 others, 40 feet of asbestos using glove bags.
Personal/ R. E. Coyner
7hrs 26min
0.034
0.0317
Collected while using glove bags to strip approx. 50 feet of asbestos, with 1 other insulator.
Personal/ S. M. Barker
7hrs 15rnin
0.0571
0.0531
Collected while using glove bags to strip approx. 50 feet of asbestos, with 1 other insulator.
Personal/ J. R. Chandler
7hrs 15min
0.0066
Personal/ S. M. Barker
7hrs 9irin
0.011
0.00598 0.0366
Collected while retrieving bags and helping with vacuun - ground man.
Collected while stripping approx. 12 feet of asbestos using glove bags. Opened vacuun cleaner to change HEPA filter had a few problems.
ASBESTOS Permissible Exposure Level TWAg Action Level
0.2 0.1
fibers/cc OSHA fibers/oc
2180P rab
UCC 024580