Document y09aLNaBMwQ9oj7GxO14MNV4

INTERNAL CORRESPONDENCE UNION CARBIDE CORPORATION TECHNICAL CENTER PQ BOX Q3B1, SOUTH CHARLESTON, WV 25303 I o INfimel Oi,,i&Kjn H. E. Rucker 512/2009 Ar ea ClJpy IT) B. H. Avashia, M.D. - 512/23 J. W. Barna - 2009/6 W. L. Browning - 2009 W. V. Filipek - 5515 C. P. Maxwell - 701/2 B. R. McMakin - 2009 0. H. Parsons - 2281 W. 0. Vincent - 514/109 "i, n.-t-,L March 19, 1987 EH&TS _ Ar,il Industrial Hygiene Asbestos Exposure Monitoring Attached are the results of the Asbestos exposure monitoring performed on insulators in the South Charleston Plant, Building 706. They were monitored over a 3 day period while using glove bags to remove asbestos from several lines, horizontal and vertical. Employees were equipped with 2 pair of coveralls, no street clothes, boots, gloves, head cover and either an A0R57A or Willson R12 Half-face, HEPA filter, respirator. The employees showered each day, before leaving the plant. The monitoring results indicate that the exposure levels were well below the 0.1 fiber/cc Action Level, established by OSHA for an 8-hour workday (TWA8). We feel that the glove bag method is a very good way of controlling airborne fibers. However, we must be sure that the procedure is followed closely by each insulator using a Glove Bag. Please inform J. R. Chandler, R. E. Coyner and 5. M. Barker of their exposure monitoring results, as soon as possible. Have them sign and date this report and return to M. A. Patel at Building 701-330. UCC 024578 Asbestos Exposure Monitoring -2- March 19, 1987 If you have any questions or if we can be of further assistance, please feel free to call us on extension 4779 or 3750. WORK BY: APPROVED BY: Vance E. Stover Attachment VES:MAP:rab 2180P Manhar A. Patel UCC 024579 ASBESTOS EXPOSURE MONITORING Carp. Ref. W2158 W2160 W2161 Date 3-11-87 3-12-87 3-12-87 3-12-87 3-13-87 Sample Type/ Enployee Name Sarrpling Time Personal/ J. R. Chandler 6hrs 57mirt Air Cone, fibers/cc 0.0314 Wq fibers/cc 0.0273 COM-ENTS Collected while stripping, along with 2 others, 40 feet of asbestos using glove bags. Personal/ R. E. Coyner 7hrs 26min 0.034 0.0317 Collected while using glove bags to strip approx. 50 feet of asbestos, with 1 other insulator. Personal/ S. M. Barker 7hrs 15rnin 0.0571 0.0531 Collected while using glove bags to strip approx. 50 feet of asbestos, with 1 other insulator. Personal/ J. R. Chandler 7hrs 15min 0.0066 Personal/ S. M. Barker 7hrs 9irin 0.011 0.00598 0.0366 Collected while retrieving bags and helping with vacuun - ground man. Collected while stripping approx. 12 feet of asbestos using glove bags. Opened vacuun cleaner to change HEPA filter had a few problems. ASBESTOS Permissible Exposure Level TWAg Action Level 0.2 0.1 fibers/cc OSHA fibers/oc 2180P rab UCC 024580