Document xzvjek4YN1Ka1R2GDKqrXGvzm

Federal Register / Vol. 51, No. 119 / Friday, June-20, 1966 / Rules and Regulations 22695 employees asa means Of controlling' exposure. Unprotected exposures above the PEL should not be permitted [Ex. 90-236). Similarly. Richard A. Lemen, Director, Division of Standards Development and mg/M3, well below the cut:off for other than high efficiency filters. Many commenters stated that nonpowered air purifying respirators should be provided with high efficiency filters prolonged storage at high humidity. The other respirator filters yielded varying results. Thus, even tinder laboratory conditions; most approved respirator filters did not provide the consistent Technology Transfer for NIOSH. and that single-use and replaceable protection necessary to ensure worker . commented: dust/mist respirators do not provide health. Worker rotation as a compliance measure must be forbidden given the lack of a safe threshold for lung cancer and mesothelioma adequate protection against asbestos [Exs. 90-49, 90-234, 91-6, 91-40,117E, 123A). Other commenters were In favor A number of commenters staledthat air purifying non-high efficiency half mask negative pressure respirators caused by asbestos [Tr. 6/21. p. 66). of more stringent respiratory protection should be permitted to be used as they The prohibition against worker rotation contained in the final standard for asbestos is. therefore, consistent with OSHA's view that this control strategy is not appropriate in _ occupational environments involving exposure to carcinogens.' 7. Paragraph (g). Respiratory Protection. such as supplied air respirators or positive pressure respirators to assure the maximum protection possible (Exs. 223. 90-147). In a letter to all respirator manufacturers published in the . American Industrial Hygiene Association lournal, Dr. Jon R. May of NIOSH staled the following: The final standard requires that On the issue of asbestos; the Institute respirators be used to limit employee wishes to state that although asbestos can exposure to asbestos in the following circumstances: (i) During the interval necessary to install or implement feasible engineering and work practice controls: produce fibrosis, this effect pales in ' significance in comparison to the known human and animal carcinogenicity of this - fibrous material. It is not our position that single-use dust respirators will provide adequate protection against the cancer (ii) In work operations such as causing potential of asbestos |Ex. 91-6). maintenance and repair activities or other activities for which the employer establishes that engineering and work practice controls are not feasible; (iii) In work situations where feasible engineering and work practice controls are not yet sufficient to reduce exposure to or below the PEL; and (iv) In emergencies. These limitations on the required use of respirators are consistent, with the requirements of the past asbestos standard, with 29 CFR 1910.1000 (e) and with good industrial hygiene practice. They reflect OSHA's determination, as Furthermore, in regards to dust, fume, and mist respirators, either with replaceable or reusable filters, Dr. May expressed concern about the filters effectively removing asbestos during the entire period of recommended use. This is based on the fact-that the air-purifying components of these devices are not tested against asbestos but rather against a fine silica dust aerosol. Norton Company! a respirator . manufacturer, stated: To obtain the greatest degree of protection available from non-powered air-purifying respirators, in asbestos environments where detailed in the preceding section on the TWA concentration is iesa.than 20 fibers methods of compliance, that respirators per cubic centimeter, Norton recommends the reliably provide protection up to ten times the permissible exposure level [F.xs. 328. 331, 339,341). E.l. DuPont DeNemours and Company submitted for. the record |Ex. 339) a study it conducted on workplace protection factors for elastomeric half-mask and single use respirators. Results of their study showed that five of six respirators tested provided workplace protection factors of ten or greater and the remaining one provided a protection factor of five or greater. Unfortunately this study was not completed in time to present at the public hearing and could not be reviewed and commented upon by other interested parties. Also, DuPont did not submit data to indicate the. magnitude of counting errors in their study. OSHA does not believe that the DuPont data proves that negative pressure air purifying respirators provide adequate protection. The study was based on evaluating only a few manufacturers' respirators. In addition, workplace protection factors obtained appeared to be inconsistent with the types of respirators tested. For instance, the 3M-9910 disposable respirator tested yielded a protection factor almost equivalent to the Scott Air-Pak (SCBA) tested, and the 3M-9910 far exceeded the protection factor of an elastomeric/ are inhere'htly less reliable than use of an elastomeric half-mask or full-, high efficiency filter. engineering and work practice controls. OSHA believes, therefore, that relying facepiece respirator with high-efficiency filters |Ex. 117E). The expected results would be that. the supplied air respirator would have a. on respirators to control exposures to OSHA acknowledges that respirator higher protection factor than the the PEL must be confined to the niter efficiency for asbestos has not negative pressure respirator. The . designated situations. been thoroughly tested (49 FR14125). A superiority of supplied air respirators is Theifinal standard requires the use of recent study by the Los Alamos recognized by all respiratory selection high efficiency-filters when.alr purifying Scientific Laboratoty (LASL),. submitted procedures in existence and conforms to respiratbrsare.used. .OSHA is to the OSHA docket [Ex. 93r5],-has cast OSHA respirator selection tables in a.U ' ' particularly concerned^ about the further doubt on the effectiveness of toxic substances to date, including the penetrability of respirator filters respirators when used specifically to existing asbestos standard, and all (including single' use respirators) other . protect against asbestos exposure. Five NIOSH criteria documents! There is no than the high efficiency type. At the new respirator niters', all of which are explanation for the inconsistent findings PEL of 0:2 f/cc, the'NIOSH/MSHA approved by the Mine Safety and Health in the DuPont studies. certification criteria require the use of Administration (MSHA) and NIOSH for Another factor that must be realized high efficiency filters (See 30 CFR 11.130 the use with asbestos, where challenged when interpreting the results of the (a) and (c)]. NIOSH certification for . . ' with an aerosol of chrysotile asbestos DuPont study is that the protection other than high efficiency filters is not under varying environmental conditions. factors reported by DuPont were based valid for. toxic substances withPEL Only one model (the high efficiency upon data gathered after the workers' values less than 0.050 mg/M3 or 2 filter) functioned.consistently well under were fit tested. According to industrial mppef. Using the conversion factor provided by CHAP [Ex. 84-246. p. Ii- 137). a PEL of 0.2 f/cc equatcs.to 0.006 all experimental conditions: (1) fresh from the package, (2) after exposure to an organic oil mist, and/or (3) after hygiene practice, if the fit testprocedures adequately work; then no workers should be expected to have GLEASON-000943