298________________ ' .Chapter IS ' 1945 Guide Solution. In order to design a radiator circuit accurately and systematically, the, cirpuit should be divided into sections. The division points, of sections must be where the pipe sizes change or may change, and where the volume,of water flowing in the pipe changes. The data relating to the several sections may be recorded as shown in Table 6. Data recorded in Table 6 show that Circuit 3 consists of 70.4 ft of pipe and 21.5 elbow equivalents. Assuming that the average size of.the pipe will be 114 in-, the 21.5 elbow equivalents may be replaced by 21.5 x 2.6 (2K?x 1.25x1.0), or 56 ft of pipe, which would make the total equivalent length of the circuit 70.4 plus .56 or 126.4 ft of pipe, and-the average/It, 1225/126.4, or about 10 milinches per foot. For this unit fh and a temperature difference of 40 F (see Fig. 3), a 1 in. pipe will convey 18 Mbh, a 1J4 in. piper 37 Mbh, and a 1 in. pipe, 56 Mbh. The pipe sizes for the several sections of Section 0-4 4-5 5-6' 6-3 3-7 7-8 8-9 .9-0 . Total Table 6. `Tabulated Data for Example 3 ' Circuit'No. 3. Available ph 1336 milinches Load Mbh 45 . 35 20 20 20 20 35 45 Pipe Length Ft 3.5 10.0 12.0 6.5 9.5 12:8 13.8 2.3 70.4 Elbows. No.. * Pipe Size In. 2.5 2.0 IX 0.0 iQ 5.5 i 5.5 i 1.0 i *2.5 2.5 21.5 Equivalent Length. Ft Unit Friction Total Milinches Friction, per Ft Milinches 11.3 15.2 12.0 17.5 6.3 9.2 3.4 13 71 . 140 41 228 20.5 14.9 20.3 10.1 13 . 13 9.2 6.3 267 194 . 187 64 121.8 1192 0-4 4-5 5-2 2-8 8-9 9-0 Total 45 35 15 15 . 35 45 Circuit No. 3.. -Available ph 1335 milinches 6.2 9.5 ' `6 7 ; : - 1 X 18.7 20.4 7.5 24.0 71 140 140 490 187 64 1092 0-4 4-10 10-1 1-11 11-9 9-0 ` Total . 45 10 10 . ' 10 10 45 ' Circuit No. 1. Available ph 1336 milinches 9.6 1.5 X 11.3 5.0 5.5 X 10.7 9.5 5.5 18.1 11.5 2.5 X 15.4 . 11 46 11 11 . 71 124 434 199 . 169 64 1067 Circuit 3 may be selected as indicated in Table 6. Having selected the pipe sizes, the unit friction heads may be found from Fig. 3 and the total friction head calculated and recorded as shown in Table 6. If the grand total, in the present case 1192 milinches, differs materially from the available ph, 1225 milinches, one or more qf the pipe sizes . must be changed andthe calculation repeated until the total }h is practically equal to the available ph of 1225 milinches. It is not necessary, in the design of hot water heating systems, to be extremely careful to have the }h exactly equal to the available ph, because a hot water heating system has the ability to adjust.itself to varying conditions of considerable magnitude. For example, in the present case, the calculated fh is 1192 milinches, or about 3 per cent less than the calculated available ph; the water would, therefore, circulate a little faster than con templated and the return temperature would be a little higher than 160 F. This would immediately lower the available ph and the ph and fh would come into balance at a value higher than 1192 and'lower than 1225. Hot Water Heating Systems and Piping 299, Since it is generally not necessary to make extremely refined calculations. Table 1 may often be used instead of the chart of Fig. 3 to determine pipe sizes. For example, in the present case. Table 1 shows that for an fh of 10 milinches a 1% in. pipe would convey 28 Mbh with a temperature difference of 20 F or 56 Mbh with a temperature difference of 40 F. Since the 1J^ in. pipe in Fig. 10 is to convey only 45 Mbh with a temperature difference of 40 F, or only 22.5 with a temperature difference of 20 F, it is evident from the table that the fh will be between 6 and 8 milinches. For 6 milinches the heat con veyed is 21.2 and for 8 milinches, it is 24.8; for 22.5 Mbh, the fh would be estimated to be about 6.5, which would be sufficiently accurate for the present calculation.. Having completed the design of Circuit 3, it is simple to design Circuit 2 because it has four sections in common with Circuit 3 and it is only necessary to design Sections 5-2 and 2-8, as shown in Table 6, so that the total fh of Circuit 2 will be practically equal to the total fh of Circuit 3. Having completed the design of Circuit 2, it is necessary to design Circuit 1, as shown in Table 6, so that its total fh will be approximately.equal to the total/A of the other two circuits since all three circuits have equal pressure heads. Two-Pipe Forced Circulation System Example 4- In the design of a system for Fig. 11, as in the design of Example 2, thereare three unknowns--pressure head, pipe size, and flow-return temperature difference, any two of which may be assumed and the third found. In the design of a system for Fig. 8, the pressure head and the temperature difference were assumed and the pipe sizes found. In this case, the pressure head is to be found. Solution. In selecting the temperature difference and the pipe sizes, it should be bornem mind that the first cost of the pipe system and of the radiation is reduced by reducing the temperature difference and by reducing the pipe sizes, but the ph and the cost -bf pumping the water are increased. The choice of temperature difference and pipe sizes which produce the greatest economy in first cost and in cost of operation can be deter mined after having made two or three trial designs. For the first, design, 20 F will be selected as the temperature difference and the pipe sizes will be chosen as shown in Fig. 11. A calculation similar to that of Table 7 will show that the fh of Circuits 1, 2, and 3