Document xzKNJzqENG8aVzDK5Xx8Nev5Q

#Lancaster Laboratories A division of Thermo Analytical Inc. LLX Sample No. TL 2795999 Collected: 10/ 3/97 at 13:45 by SN Submitted: 10/ 3/97 Reported: 10/24/97 Discard: 11/24/97 CWK-BD-49 Soil Sample TCLP ZERO HEADSPACE EXTRACTION Chambers Works Soil Reuse Job #6015-08-06 SAMPLE MDL SAMPLE UNITS BLANK Account No: 07032 DERS/DuPont Env Reined Services Barley Mill Plaza, Bldg. 27 Routes 141 & 48 Wilmington DE 19805 DUP RPD MS MSD MS RPD P.O. LBIO-62248 Rel. L146 LCS LCS L LCS DUP RPD L (1 I I 3503 Chioroform 0.0050 mg/1 3504 1,2-Dichloroethane 0.010 mg/1 0316 2-Butanone 0.015 mg/1 3506 Carbon Tetrachloride 0.0050 mg/1 3511 Trichloroethene 0.0050 mg/1 3515 Benzene 0.0050 mg/1 3522 Tetrachloroethene 0.0050 mg/1 3525 Chlorobenzene 0.0050 mg/1 0948 TCLP Volatiles N.D. 102 114 11 N.D. 103 118 14 N.D. 110 137 22 N.D. 104 110 6 N.D. 107 114 6 N.D. 110 124 12 N.D. 102 107 5 N.D. TRIAL ID 103 113 10 .ss.ss.s.ss.s..=;.=.s:.s=.s.s:.s.=s. SS.SS.SS. SURROGATE SUMMARY SURROGATE d4-l,2-DCA d8-toluene 4-BFB RECOVERY % 89 92 93 SURROGATE LIMITS LOW HIGH 76 114 88 110 86 115 CAT NO 0948 0946 ANALYSIS NAME TCLP Volatiles TCLP Zero Headspace Extraction METHOD SW-845 8240B SW-846 1311 LABORATORY CHRONICLE TRIAL 1 1 ANALYSIS DATE AND TIME 10/14/97 1034 10/07/97 1630 ANALYST Ann L. Rishel Debra A. Bryan State of New Jersey Lab Certification No. 77011 HIGH Questions? Contact your Client Services Representative Nancy Bornholm at (717) 656-2300 ? \/Uuj t SU1 EMBER Lancaster Laboratories 2425 New Holland Pike PO Box 12425 Lancaster, PA 17605-2425 717-656-2300 Fax:717-656-2681 Respectfully Submitted Ramona V. Layman Manager. Metals/Leachates See reverse sice for explanation of symbols and abbreviations. 2216 Rev. 8/A'<?7 DUP050464930 Explanation of Symbols and Abbreviation? The following defines common symbols and abbreviations used in reporting technical data: M.D. TNTC m umhos/cirt C Cal maq 9 ug ml m3 none detected Too Numerous To Count International Units micromhos/cm degrees Celsius (diet) calories rnilliequivalents gram(s) microgram(s) milllliter(s) cubic meter's! BMQL MPN CP Units NTU F Sb. kg mg j ui fib >5 urn/ml Below Minimum Quantitation Level Most Probable Number cobalt-chloroplatinate units nephelometric: turbidity units degrees Fahrenheit pound(s) kilogram(s) milligram(s) liter(s) microiiter(s) fibers greater than 5 microns in length per ml < > ppm ppfc Dry weight. basis less than - The number foflowinci the sian is the limit of auantitation. the smallest amount of analyte which can be reliably determined using this specific test. greater than parts per million One ppm is equivalent to one milligram. per kilogram tmg/kg), or one gram per ml Ikon prams. For aqueous liquids, ppm is ususFy taken to be iequivalent to milligrams per Tier (mg/15, because one i-ver of water has a weight very dose to a kilogram. For gaser> or vapors , one ppm is equivalent to one nicroliter of gas per liter of gas. parts per billion Results prinied under this neadmg have been adjusted for mo slum content This me'eases the analym weight concentration Vo approximate the value present in a similar sample witnoui. moisture US. EPA data qualifiers. Organic: Qualifiers Inorganic Qualifier-? A TIC is a possible aldoi-condensation product B Value is <C.RDl , but >IDL & Analyte was also detected in the blank c Pesticide result con*erred by GC/MS c Estimated due to interference M Duplicate injection owewen nm -nei D Compound quantitated on a diluted sample E Concentration exceeds the tali oration range of n Spike sarnpie not vvirhm control limits s Method of standard auditions IMSA) used the instrument for ca'Ojia;.on j Estimated value u Compound was not detected H Presumptive evidence of a compound (TICs only) W Post digestion spike out of control limits P Concentration difference between primary and * Duplicate analysis not w.-thm control limits confirmation columns >25% Correlation coefficient for MSA <0)995 U Compound was not detected X,Y.Z Defined in case narrative Tests results relate only to the sample tested. Clients should be aware that a critical step in a chemical or microbiological analysis is the collection of the sample. Unless the sample analyzed is truly representative of the bulk of materia! involved, the test results will be meaningless. If you have questions regarding the proper techniques of collecting samples, please contact us. We cannot be held responsible for sample integrity, however, unless sampling has been performed by a member of our staff. This report shall not be reproduced except in full, without the written approval of the laboratory. WARRANTY AND LIMITS OF LIABILITY - In accepting analytical work, we warrant the accuracy of test results for the sample as submitted. THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IS GIVEN.IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. WE DISCLAIM ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING A WARRANTY OF FITNESS FOR PARTICULAR PURPOSE AND WARRANTY OF MERCHANTABILITY. IN NO EVENT SHALL LANCASTER LABORATORIES BE. LIABLE FOR INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS Or PROFIT OR GOODWILL REGARDLESS OF (A) THE NEGLIGENCE (EITHER SOLE OR CONCURRENT) OF LANCASTER LABORATORIES AND (B) WHETHER LANCASTER LABORATORIES HAS BEEN INFORMED OF THE POSSIBILITY OF SUCH DAMAGES. We accept no legal responsibility for the purposes for which the client uses the test results. No purchase order or other order for work shall be accepted by Lancaster Laboratories which includes any conditions that vary from the Standard Terms and Conditions of Lancaster Laboratories and we hereby object to any conflicting terms contained in any acceptance or order submitted by client. DUP050464931