Document xzKK3012r1e20LGpvqzqop3B6
( ETHYL CORPORATION
To
From Subject
INTER-OFFICE
Mr. J. M. Riddle
. ir
/M
V'l
E. Whitehead Elmore
{.i \
Vinyl Chloride Monomer/Potential
Health Hazard
Yesterday Dr. Rinehart, Jim Brierley, Ted Bordelon and I met to discuss the above-captioned subject and the proper approach in relationship to customers. Apparently there is no substantial risk insofar as customers of PVC are concerned, but the risk is potentially real as to VCM customers. Accordingly, Dr. Rinehart has drafted and I am attaching to this memorandum a form of letter which I have approved for use in notifying our VCM customers of the need for extra caution and employee briefing in connection with VCM. You will note Dr. Rinehart's letter refers to MCA Chemical Safety Data Sheet SD-56 as revised in 1972 and indicates that a label will be affixed to the cover of that data sheet indicating the threshold limit value has been reduced from 500 ppm to 200 ppm. For information, I have Xeroxed and am attaching to this memorandum an excerpt from the data sheet concern ing the possible carcinogenic effect of vinyl chloride monomer. A let ter similar to the one drafted by Dr. Rinehart has been sent by Dow Chemical Company to its VCM customers.
You may want to send copies of the letter to 1CD salesmen so that inquiries from customers will be understood by them. You will note the last sentence of Dr. Rinehart's letter is an invitation for as sistance from Ethyl. Any request for assistance appropriately should be referred to the Medical Department and Dr. Rinehart in particular.
Messrs. Freberg, Ramin and Whitlock are on the distribution, since International and/or Ethyl of Canada may decide to use a similar letter for their customers, with some required redrafting.
Jim Brierley has indicated he will notify our insurance brokers as a precaution, informing them that we are taking necessary steps with our customers and in our own plant. I do not know what action we are taldng as of yet in our own plants, but 1 understand Dr. Rinehart has
y
Produced underOlder 1/11/00 in BfBtt&UlGSD #90-4837 e/wljntjon #97-7949
14th Judicial District Court, State of Louisiana AH claims (^privilege, work product and confidentiality reserved m all other matters.
VC?880
Mr. J. M. Riddle
-2
March 23, 1973
discussed this matter with Mr. Armstrong and we plan to initiate a sampling program and take other action as appropriate within our safety program.
EWE:nsj Attachments.
CC:
W. F. Armstrong T. J. Bordelon J. I. Brierley K. A. Freberg M. F, Gautreaux J. M. Gill M. L. Gould C. W* Montgomery R. A. Moser C. M. Neher F. W. Ramin H. W. Rees W. E. Rinehart F. P. Warne M. Whitlock
ProAiced underOrder1AlflQ in Rest* fitwncp *0041X1 dvt 1anrion #97-7949 14th Judicial District Coun, State of Louisiana. AH claims or privilege, work product and confidentiality reserved in ail other matters.
VC2890
Gentlemen: Since you are a valued customer for Ethyl's vinyl chloride
monomer, we feel we should alert you to the fact that there has
by
been a recent change in thinking, as to permissible employee exA
posure. Enclosed is a copy of the MCA Chemical Data Sheet (SD-56) for vinyl chloride which was revised in 1972. More recently, but still in 1972, the American Conference of Governmental Industrial Hygienists has1' adopted a threshold limit value (TLV) of 200 ppm.
have noted this on the label affixed to the cover of the enclosed bulletin.
We urge you to review with your employees the properties, potential hazards and procedures for handling vinyl chloride as they appear in the data sheet.
In many installations which handle vinyl chloride, it has been found that it is technically feasible to maintain employee exposures to levels even lower than 200 ppm* Such practice, will, of course, provide an even greater margin of safety than exists with the allowable limits of exposure. We recommend you review your handling practice with the goal of reducing exposures wherever possible. If we can be of any service, we would be happy to dis cuss this further with you.
Very truly yours.
M. L. Gould Manager Industrial Chemicals Division
VC2B91
Vinyl Chloride
Momrfocfvring Chomiitj Association
MmI )Im*i
so-**
0
available to man the lifeline and to assist in the
VCM should be done after the container has been
rescue if needed. The rescuer should be in view of
thoroughly ci.'ancd of VCM sapors Purging <houiJ
the outside attendant at all times or tn voice com*
be tested by a competent person to sec it It is free of
munication with him.
VCM. It is not recommended that air be used to purge a vessel.
8.5 EXTERIOR REPAIR WORK
If the repair work is interrupted, the tank atmos
All outside welding, burning or spark-producing
phere should be checked thoroughly and a new work
work on tanks or equipment which have contained
permit issued before resumption of work.
9. WASTE DISPOSAL (See 7.5)
9.1 All Federal, State, and Local regulations re garding health and pollution should be observed. Disposal of waste material, however, depends to a great extent upon surroundings, weather conditions and the emergency making disposal necessary.
9.2 When it becomes necessary to dispose of VCM as such, it is preferable to do so as a vapor, venting to an area free of any source of ignition.
9.3 When a waste disposal problem arises as a result of a major spill or equipment rupture, only properly protected and qualified personnel should remain in the area.
9.4 Waste mixtures containing VCM should not be allowed to enter drain or sewers as serious explosions in such systems may result.
10. MEDICAL MANAGEMENT
10.1 HEALTH HAZARDS
10.1.1 Vinyl chloride monomer docs not present
a serious industrial health hazard provided workers are adequately supervised and observe the proper
means of handling it. Under the Occupational Safety and Health Act. the L'.S. Department of Labor has set a 500 ppm Ceiling Value on permitted employee
exposures. Based upon animal and human observa tions, this level provides considerable margin of safety for industrial exposures.
Note: A syndrome termed occupational acro-
ostcolysis. characterized primarily by Raynaud's
phenomenon and osteolytic changes in certain bones,
particularly the distal phalanges of the hands, has
been noted among certain workers in vinyl chloride
polymerization operations. The specific cause of this
disease, and particularly any role played by vinyl
chloride, is unknown.
'
Recent rcsearcEstudics reported from Italy in^
dicate that repeated, long-term high level exposures
of rats to vinyl chloride monomer vapor can result in
the development of malignant tumors. However,
many years of industrial experience with human ex
posures to concentrations frequently far above cur
rent standards have not demonstrated any carcino
genicity to humans.
.
10.1.2 Acute
Levels on the order of 6,000 ppm for five minutes exposure are required to produce minimal
symptoms resembling mild alcohol intoxication in humans. Levels approximately 16.000 ppm for the same length of time will produce varying degrees of intoxication, with light-hcadcdness. some nausea, and a dulling of visual and auditory responses in most humans.
10.1.3 Chronic Toxieity
The liver is the principal target resulting from excessive chronic exposure. The currently recom mended ceiling level (OSHA) of 500 ppm is welt below a level producing any signs or symptoms of toxicity.
10.2 PREVENTIVE MEASURES
10.2.1 All operations in which vinyl chloride is used should be regularly evaluated and atmospheric concentrations kept, at all times, below 500 ppm. Sophisticated air sampling techniques arc required. This includes gas chromatography. Processes must be closed or ventilated sufficiently to achieve a con centration control low enough so that respiratory protection devices are needed only on an emergency basis.
10.2.2 Personal Hygiene
Vinyl chloride should be.kept off the skin and out of contact with the eyes. If accidental contact to the skin occurs, immediate washing with soap and water necessary; if to the eyes, immediate irrigation
17
Produced underOrder1/1MJO in Rimfonn #9MS37 dmLandfill I4ih Judicial District Coun, State of Louisiana. AM claims ofprtvilegc, work product and confidentiality reserved ift aU other matters.
/