56-55B GROUND WAfER NEWSIOTCR LQ.W.
JAN 17 1977
CUI'i'i.O RYl BAffOWS)
K'B' - CONTAMINATE FOIL DESPITE CONTROL?
.
" ** ~ ,,xj_borne~ ~transportation of PCB1 s, either from the point of raanu-
faoture or from plants using the materials, may be the principal path
way to contamination of soil end water nearby rather than actual dis
.
charge oif treated plant waste waters or runoff over soils. A new sur
vey reports the degree of environmental contamination attributable to
polychlorinated biphenyls and terphenyls in the vicinity of .the Monsanto .
Company's manufacturing plant in Sauget, IL., the only source of domes
tic production of PCB's and PCT'sl and at plant sites of two users lo
cated in urban Chicago and suburban Detroit.*
The Monsanto products, marketed under the trade name of Aroclors,
have been subjected to strict production controls since 1970. At the
same time the company voluntarily ceased supplying those users who
could not control release to the environment. However, the survey
showed that "voluntary control of the release of PCB's and PCT's to the
environment by industrial sources cannot be considered entirely ef
fective." Much of the contamination of water and soil present in sam
ples probably occurred since 1972, two years after controls were in
stituted.
__ _
Surface soil samples were collected from sites at all three loca-
Lons. At Sauget the spatial distribution of the materials in the soil
unples indicated that "the entire PCB and PCT mixture is in a vapor
tate at the point of emission." The plant operates a liquid injection
icinerator to dispose of in-house liquid wastes and contaminated
CB's. Soil concentrations were as high as 19 ppm at some sampling
points . Tests at the plants using the materials showed little evidence or contamination of water in a drainage ditch, but PCB's and PCT's were both present in the bottom samples of the ditch. Sludge deposits with in the sewer system serving the Detroit user contained 0.14 ppm PCB and 5.0 ppm PCT. on a dry weight basis, indicating "intermittent dis charge is taking place to the sewer system."
*"PCB and PCT Contamination in the Environment Near Sites of Manu facture and Use." Environmental Science & Technology, Vol. 10, No. 13.
,
HONS 001697