Document xyeY1rZRZ8aq2mMvMEwEXK6G
Monsanto
TO
b, p, Qtiand i W.D - W. 0. Krummrlch Plant
November 6, 1974 PCB Investigation
E. Kelly, N.D. - A2SA 0. A. Hippo H. J. Horner
This Investigation was prompted by tha safety suggestion of Nr. Jim Paco dated June 29. 1974. He euggested that a possible Aroclor in bodies with people working with the materials might be harmful to the laboratory workers. The procedure for handling this Investigation was as'follows: blood tests wore done on the people who had personal con tact with the chemical, the samples were submitted to Nr Orville Hicks In the General Offices for Aroclor deteral.tlon, and the remaining blood samplea were submitted to Clinical Laboratories In St. Louis for liver function tests.
* The oopy of Nr. Hicks work is enclosed for your inspec tion. The only significance Is that the ppb of Aroclor 1254 determination showed Infinitesimally email amounts detected. The two people who had the largest amount of Aroclor 1254 In ppb detected showed no obvious clinical ohange In their serological blood tests. Hemograms were done on all the subjects and these were within normal limits. Because of the wide variation In the reporting of the liver function testa, these were submitted to two laboratories and only oonflmed abnormalities by both laboratories will be con sidered. A copy of these reports In a chart form with the'? normal variations will be Included In this report.
There were two Individuals,
and
w:
had confirmed elevations of abnonsal liver function test!
Although theso were relatively small they should bo taker,
into consideration. Both of these individuals had no detect
able PCS In their blood.
One might eenelude from this aummtlon that If there Is a "liver abnormality" it Is not work related but due to seme extraneous cause and perhaps should be Investigated from another clinical standpoint.
In summary, six laboratory workers were Investigated for their exposure to PCB and It's possible teratogenic, carcino genic and patho physiological effects. The amount of PCB detected was extremely low. The amount of abnormality discovered In the battery of the liver function test was net conclusive In that there waa no consistency to the reported abnormality.
/ghw
R. D. Osland, N.D.
HONS 004134
>wit<kw*ihd lituU&TklAL CHEMICALS CO* * iwm mtniBi Orville Hick* - T2F - General Offices
, . Septeaber II. 1974 MaM* .
WIMMt
. R. 5. Kaley - T2F R. E. Keller TIB E. S. Tucker . T2F Or. R. E. Kail/ A2SA
TO : Di. 0. ffTIand' ,TT U. S. Kruaa'rTch~Ned1cel Oepartaont 1740
The six blood saaplas ind blank tuba were analyzed for FCIs via our noraal procedural. Tha chroaatograea obtalnad ware slallar to Aroclor 12S4 andwere ca1culated~as such. Another peak with a retention tine Identical to DOC was observed and results are reported below.
Sanpla
Reagent Blank Blood Tdbe Blank
1/13 B/1S
e/lS
PPI Aroclor 1254
11 11 n.d. <S 35 n.d. <5
PPI 00E
n.d. <2 n.d. <2
10 6 4
'8/15
S/1S B/16
7 9 12
6 9 5
n.d. none detected Figures for people are corrected for blanks
If we can be of further service, please call.
a.. Orville Hicks db
v\*
MOWS 004135
CBC
Total 811. _
LDH
SOOT SGP-T
CL normal %.4(.15-1.0) 188(100-225) *%8 (7-40) 90 (0-25) ICL Normal *1.4(.15-1.0) ^34(100-225) 34 (5-40) 54 (10-30)
CL N
.88
185
ks3
9
ICL N
1.0
212
23 11
CL N
.31
200
1*7
17
ICL N
.3
>314
19 22
CL N ICL N
.48 .5
1288 >289
38 5 32 19
CL N ICL N
.89 .7
200 . >272
9io 29
18 22
CL N ICL M
.21 .2
,.201 >243
>50 19
8 5
HONS 004136