20 D. E. Hickish and K. L. Knicjit
Table J. Assessment of fibrous fractions of dost samples
Sample
Percentage of panicles
seen to be fibrous
Sample
Sample
not incinerated
incinerated
Brake lining materia!
Brake drum dust Air-borne dust
28 12-3 0 6 1-6
-- 1-3
ft is clearly shown that the percentage of fibres in the drum dust and airborne dust is much tower than that in the dust formed from the original lining material.
Samples of drum dust were examined by Dr S. Holmes, and his tests showed that chrysolite was present only in trace quantities, or at most at 1 per cent, compared with the original lining content of 40-60 per cent. These findings suggest that there is a change in the physical and or chemical form of the asbestos during its use as a brake material.
Enquiries were made of research workers in the UK and USA as to whether they had observed a similar effect. Lynch (1968) reported that tests on brake testing dyna mometers had shown the presence of few or no fibres in the dust produced from bus and automobile brakes, except under severe braking conditions. In the latter instance, the brake temperature reached 320-370C, compared with the design maximum tem perature of 290-320C, and it appeared that, under these conditions, the binder decomposed and released part of the asbestos as free fibre. At lower bulk lining tem peratures within the normal operating range, the binder behind the surface remains intact. However, the spot temperature at the point of contact between the lining and the drum may be higher than the decomposition temperature of asbestos. The decomposition product, therefore, includes not free asbestos fibres but a different mineral, resulting from thermal metamorphosis.
Holmes (1967) in reporting the analyses described earlier in this paper, com mented that the normal thermal decomposition product of chrysotilc is forsterite, a non-fibrous crystalline magnesium silicate. However, our samples of brake drum dust contained very little forsterite, but rather were mainly comprised of an amor phous magnesium silicate, which is non-fibrous. Little was known at that time about the structure and composition of this substance. Whilst there was no evidence to suggest that the material was a health hazard, this possibility could not be dis missed, and animal experimentation has been commenced in the U.S.A.
CONCLUSIONS
Our investigations show that exposure to asbestos during brake maintenance is not as severe as was anticipated, .and in the situations we examined, the personal exposure of the operators was below lire limit corresponding to 50*ycar exposure.
It is however recommended that care should be exercised during brake cleaning to avoid inhalation of the dust produced, and the development of cleaning procedures which would reduce air contamination is desirable. The present trend towards the