Document xjZJEgEmk3KpaL6gg8nL4G23J
480
CHAPTER 33
Table 1 .... Typical Ultimate Analyses for Coals
Btu pet lb
ConjJihienfr, Percent
fen*
Moat, Mineralmatter*
fro**
MoW, <31
Received
Oxygen Hydrogen Carbon Nitrogen
Suffer
Anthracite.......................................... 14,600
12,910
5.0
2.9 80.0
0.9
0.7
Semi-Anthracite.............................. 15,200
13,770
5.0
3.9 80.4
1.1
1.1
Low-Volatile Bituminous............. 15,350
14,340
5.0
4.7 `81.7
Medium-Volatile Bituminous___ 15,200
13,840
5.0
5.0 79.0
1.4
High-Volatile Bituminous A . ... 14,500
13,090
9.2
5.3 73.2
1.5
2.0
High-Volatile Bituminous B. ... 13,500
12,130
13.8
5.5 68.0
High-Volatile Bituminous C....... 12,000
10,750
21.0
5.8 60.6
Sub Bituminous B.......................... 10,250
9,150
29.5
6.2 52.5
1.0
Sub Bituminous C.......................... 9,000
8,940
35.8
6.5 46.7
0.8
0.6
lignite................................................ 7,500
6,900
44.0
6.9 40.1
0.7
1.0
1960 Guide
Ash
o,+ H, + C
9.6 7.3 91.0
legends F.C a Fixed Carbon.
Table 2 .... Classification of Coals by Rank*
VA 1 Volatile Matter.
Btu " British thermal unity.
Group
limits of fixed Corfcon or Bht McoerafMatter-Free Boris
Requisite Physical Properties
II. Bituminous4.
III. Sab-bituminous.. IV. Iignitic..
1. Meta-anthracite........ Dry F.C., 98 percent or more (Dry V.M.,
2 percent or less) 2. Anthracite.................. Dry F.C., 92 percent or more and less
than 98 percent (Dry VM., 8 percent Non-agglomerating
or less and more than 2 percent)
3. Semi-anthracite........ Dry F.C., 86 percent or more and less
than 92 percent (Dry VM., 14 percent
or less and more than 8 percent)
1. Low volatile bitu- Dry F.C., 78 percent or more and less minous coal................ than 86 percent (Dry V.M., 22 per
cent or less and more than 14 percent) 2. Medium volatile bi- Dry F.C., 69 percent or more and less
tuminous coal.-.......... than 78 percent (Dry VM., 31 percent
3. High volatile A bituminous coal...........
or less and more than 22 percent) Dry F.C., less than 69 percent (Dry
V.M., more than 31 percent); and
Blither agglomerating* or nonweathering1
moist* Btu, 14,000* or more
4. High volatile B bi- Moist* Btu, 13,000 or more and less than tuminous coal............ than 14/0*
5. High volatile C bi- Moist Btu, 11,000 or more and less than tuminous coal............ 13,000*
1. Sub-bituminous A Moist Btu, 11,000 or more and less coal............................... 13,000*
2. Sub-bituminous B Moist Btu, 9500 or more and less than coal............................... 11,000*
3. Sub-bituminous C Moist Btu, 8300 or more and less than coal............................... 9500*
1. Lignite......................... Moist Btu less than 8300 2. Brown coal................. Moist Btu less than 8300
Both weathering and non-agglom erating*
Consolidated Unconsolidated
* This
does ne* includa a fare ccelz irhieb have aauaosi physiol ad chemirsl properties sad which corns within tbs limits of fixed carbon or Btu of
the bitaminoas end snb-bitamiaoni realm. AH of these coals either --less than 48 percent dry, mineral-mstter-froe fixed carbon, or have more than Uf moat, miMat-matter-fna Btu.
b If aMflocnaratias, classify in low-mlatilo croup of tbs bitaminoas rites,
* Moist Bta refers to coal containing its natural bed moisture but not includiag vtafble water on the surface of the coal. 4 It is recognised that there may be uoa-eaUnc varieties in each group of the bituminous cleat.
* Coals bating 89 percent os tame fixed carbon onthe dry, mmeral-matter-tree bass shallbe classified according to fixed carbon, regardless of Btu.
> There are three varieties of coal in the high-volatile C bituznizmus coal group, namely. Variety i, agglomerating and non.weathering; Variety I, agglomerating and weathering; Variety 1. aon-sggiomerating and non-weathering.
Fuels and Combustion
Table 3___ Standard Anthracite Specifications*
Test Mesh Round
Six* Cod
TfcroogA In.
Over in.
Overturn
Uoderrixe %
% Max Men
Moxaneet Impurities %
1*e
o > *5 5> <
Broken.. 4H 3>i to 3
Egg......... 3K to 3 2Ht
Stove-- 2H
m
Nut........ m
'He
Pea........ Ht
Ht
Buck-
wheat... He
Hi
Rice____ He
Ht
Barley... Hi
Hi
No. 4.. . Hs
Ht
No. 5. . . Ht
-- 5 7M
10
10 10 10 20 30
15 7M IK 15 7M IK 15 7H 2 15 7X 3 15 7H 4
15 m 17 7H 20 10 30 10 No limit
2 2 3 4 5
11 11 11 11 12
13 13 15 15 16
Approved and adopted, effective July 18,1M7, by the Anthracite Committee {Manual a/Statistical Infarusatiess. Anthracite Instituted
* When elate content in the aieea from Broken to Nut indurive h lees than above standards, bone content may bo increased by one and one-half times tbs decrease in the elate content under the allowable limits, but slate eontent sped* find above ehall not be exceeded in aoy event.
* Ash determination! are on a dry bads and indode bone and ash.
A trdr~- of 1 percent is allowed on the maximum percentage of underaise and the maximum percentage of ash contest. The maximum percentage of under size is applicable only to anthracite as it ia produced at the preparation plant.
Elate b 4-f aa any material which baa lew than 40 percent of fixed carbon-
Bone b defined as any material which has 40 percent or mare, but less than 7S percent d fixed carbon.
soot are possible, if improperly fired, especially at low rates of burning,
Sub-biLuminous coals occur In the western states; .they are high in moisture when mined and tend to break'up as they ary or when exposed to the weather; they are liable to ignite spontaneously when piled or stored. They ignite easily and quickly, and have a medium length flame; are non-caking and free-burning; the lumps tend to break into 8mall pieces if poked; very little smoke and soot are formed.
lignite is of woody structure, very high in moisture as mined, and of low heating value; it is dean to handle. It has a greater tendency than the sub-bituminous coals to disintegrate as it dries, and it also is more liable to sponta neous ignition. Freshly mined'lignite, because of its high moisture, ignites slowly. It is non-caking. The char left after the moisture and volatile matter are driven off burns very easily, like charcoal. The lumps tend to break up in the fuel bed, and pieces of char falling into the ashpit continue to burn. Very little smoke or soot is formed.
Classification of Cokes
Coke is produced by the. distillation of the volatile matter from coal. The type of-coke depends, on. the coal or mixture of coals used, on the temperatures and time of distillation and, to some extent, on the type of retort or oven. Petroleum coke is produced as a residue from the destructive distillation of oil.
. COMBUSTION OF SOLID FUELS
Firing Methods for-Anthracite
An anthracite fire should never be poked or disturbed, as this serves to bring ash to the surface of the fuel bed, where it may melt into clinker.
Egg size is suitable for large fire-pots (grates 24. in. and over) if the fuel can be fired at least 16 in. deep. For best results this coal should be fired deeply.
481
Stove is the proper size of anthracite for many boilers and furnaces. It burns well on grates at least 16 in. in diameter, on which it is fired about 12 in. deep. The fuel should he
fired deeply and uniformly. Chestnut size coal is in demand for fire-pots up to 20 in.
in diameter, and is usually fired to a depth of from 10 to 15 in.
Pea size coal is often an economical fuel to burn. When fired carefully, pea coal can be burned on standard grates. Care should be taken to shake the grates only until the first bright coals begin to fall through the grates. The fuel bed, after a new fire has been built, should be increased in thiolrtiasa by the addition of small charges until it is at least level with the sill of the fire-door. A satisfactory method of firing pea coal consists of drawing the red coals toward the front end, and piling fresh fuel toward the back of the firebox.
Pea size coal requires a strong draft, and therefore the best results generally will be obtained by keeping the choke damper open, and regulating solely by means of the cold-air check and the air-inlet damper.
Buckwheat size coal, for best results, requires more at tention than pea size coal, and in addition the smaller size of the fuel makes it more difficult to bum on ordinary grates. Greater care must be taken in shaking the grates than with the pea coal to prevent fuel from falling through the grate. In house heating furnaces, the coal should be fired lightly and more frequently than pea coal. When banking a buckwheat coal fire, it is advisable after coaling to expose a small spot of hot fire by putting a straight poker down through the bed of fresh coal. This will serve to ignite the gas that will be distilled from the fresh coal and prevent delayed ignition which, in some cases, depending upon the thickness of the bed of fresh coal, is severe enough to blow open the doors and dampers of the furnace. Where frequent attention can be given and care is exercised in manipulation of the grates, this fuel can be burned satisfactorily without the aid of any special equipment, except small mesh grates.
In general, it will be found more satisfactory with buck wheat coal to maintain a uniform beat output and, con sequently, to keep the system warm all the time, rather than to allow the system to cool off at times and then to attempt to burn the fuel at a high rate while wanning up. A uni form low fire will minimize the clinker formation and keep any clinker formed in an easily broken up condition so that it readily can be shaken through the grate. Forced draft and small mesh grates or, for greater convenience, domestic stokers are frequently used.
Buckwheat anthracite No. 2, or rice size, is used princi pally in stokers of the domestic, commercial and industrial type. No. 3 buckwheat anthracite, or barley, has no ap plication in domestic heating.
Firing Methods for Bituminous Coal
A commonly recommended procedure for firing domestic beating units, called the side-bank method, requires the movement of live coals to one side or the back of the grate, and placing the fresh fuel charge on the opposite ride. The results are a more uniform release of volatile gases, and the subjection of these gases to the high temperature of the red coals. If the fresh charge is covered with a layer of fine coal, still better results may be obtained because of slower release of volatile matter.
Bituminous coal should never be fired over the entire