Document xjR0w6r08Eg51nBDqGR1w4ejG

ascojjttE ^laboratories, ,3(nc YOUR ON-TIME QUALITY LAB... Baltimore, MD 21224 REPORT Radian International 8501 North Mopac Blvd Austin, TX 78759 (410) 633-1800 (800) GAS-COYN FAX NO. (410)633-5443 Page 1 of 11 www.gascoyne.com Report No: 9704087 Attn: Heidi Krall This report of analysis contains test results for the following samples submitted to Gascoyne Laboratories, Inc.: Client Sample I.D., DOW-VP-LW-31 -VI9-PHY, 15-Sep-1997 DOW-VP-LW-32-V18-PHY, 16-Sep-1997(1300) DOW-VP-LW-33-V18-PHY, 16-Sep-1997(2000) DOW-VP-LW-21 -VI5-PHY, 18-Sep-1997 DOW-VP-LW-22-V15-PHY, 18-Sep-1997 DOW-VP-LW-23-V12-PHY, 18-Sep-1997 DOW-VP-LW-11 -VI 5-PHY. 17-Sep-1997 DOW-VP-LW-12-V13-PHY, 17-Sep-1997 Sample Type Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Lab Sample No. 970021039 970021040 970021041 970021042 970021043 970021044 970021045 970021046 Received by Gascoyne 25-Sep-1997 25-Sep-1997 25-Sep-1997 25-Sep-1997 25-Sep-1997 25-Sep-1997 25-Sep-1997 25-Sep-1997 DO A 049057 OONFTDFNTTAI YOUR ON-TIME QUALITY LAB!.. Baltimore, MD 21224 Radian International 8501 North Mopac Blvd Austin, TX 78759 Attn: Heidi Krall (410)633-1800 (800) GAS-COYN FAX NO. (410) 633-5443 www.gascoyne.com Page 2 of 11 Report No: 9704087 Client Sample I.D., DOW-VP-LW-13-V13-PHY, 17-Sep-1997 This Report contains the following: A) Cover Letter B) Test Results C) Chain-of-Custody Sample Type Liquid Lab Sample No. 970021047 Received by Gascoyne 25-Sep-1997 All samples were analyzed following EPA protocols and other recognized methodologies as specified in the report. All laboratory Quality Control(QC) data associated with this report are within established control limits unless otherwise noted in this report. Gascoyne Laboratories, Inc. laboratory identification numbers: Maryland :109; Delaware: MD015; Virginia: 00152; New Jersey: 60637; Pennsylvania: 68-339 West Virginia: 9901 (C) and 054; New York: 11158; A2LA: 410.01; AIHA:8885; US Army Corps of Engineers; and EPA ICR: ICRMD003. The analyses specified in this report may or may not be included in the scopes of the above listed certifications. This cover page is an integral part of this report and must be included with all copies of this report. Report issue date OO A 049253 GONFTDFNTT Al (Basca^ne Jlaimrattfmg, YOUR 0N-TIME QUALITY LAB!.. Baltimore, MD 21224 REPORT OF AWALY8DS Page 3 of 11 (410) 633-1800 (800) GAS-COYN FAX NO. (410) 633-5443 www.gascoyne.com Rep rtn : 9704087 Client: Radian International Sample Id: Submitted samples: DOW-VP-LW-31-V19-PHY collected on 15-Sep-97 Laboratory Sample Number 970021039 Parameter Residue on ignition Test Results Reporting Limit Method Analyst Date of Analysis 0.01 % 0.01 % ASTM-D 482 PRG 09-Oct-97 Heat of Combustion 6300 BTU/LB 500 BTU/LB ASTM-D 3286 PRG 08-Oct-97 Density of Liquids 1.33 g/cc 0.001 g/cc ASTM-D 4052 PRG 08-Oct-97 Total Halogens(as Cl) 65 % 0.05 % ASTM-D808 PRG 07-Oct-97 Viscosity Sample/Test Notes: Viscosity was determined at 21C. 1.6 cst 0.01 cst ASTM-D445 PRG 08-Oct-97 DO A 049754 CONFTDFNTTAL 3fnc~ YOUR WI-TIME QUALITY LAB!.. Baltimore, MD 21224 REPORT OF ASH1ALYS3S Page 4 of 11 Rep rt no: 9704087 Client: Radian International Sample Id: Submitted samples: DOW-VP-LW-32-V18-PHY collected on 16-Sep-97(13:00) Laboratory Sample Number 970021040 (410) 633-1600 ' (800) GAS-COVN" --' FAX NO. (410) 633-5443 www.gascoyne.com Parameter Residue on ignition Test Results Reporting Limit Method Analyst Date of Analysis <0.01 % 0.01 % ASTM-D 482 PRG 09-Oct-97 Heat of Combustion 6700 BTU/LB 500 BTU/LB ASTM-D 3286 PRG 08-Oct-97 Density of Liquids 1.33 g/cc 0.001 g/cc ASTM-D 4052 PRG 08-Oct-97 Total Halogens(as Cl) 58% 0.05 % ASTM-D808 PRG 07-Oct-97 Viscosity Sample/Test Notes: Viscosity was determined at 21C. 1.5 cst 0.01 cst ASTM-D445 PRG 08-Oct-97 DO A 049255 CONFTOFNTTAl Bn&cagm( ^Gahrrratirrteg, YOUR ON-TIME QUAUTY LAB!.. Baltimore, MD 21224 ^EF!RT F AMALYS38 Report no: 9704087 Page 5 of 11 Client: Radian International Sample Id: Submitted samples: DOW-VP-LW-33-V18-PHY collected on 16-Sep-97(20:00) Laboratory Sample Number 970021041 (410) 633-1800 (800) GAS-COYN FAX NO. (410) 633-5443 www.gascoyne.com Parameter Residue on ignition Test Results Reporting Limit Method Analyst Date of Analysis <0.01 % 0.01 % ASTM-D 482 PRG 09-Oct-97 Heat of Combustion 6400 BTU/LB 500 BTU/LB ASTM-D 3286 PRG 08-Oct-97 Density of Liquids Total Halogens(as Cl) 1.33 g/cc 0.001 g/cc ASTM-D 4052 PRG 08-Oct-97 65 % 0.05 % ASTM-D808 PRG 07-Oct-97 Viscosity Sample/Test Notes: Viscosity was determined at 21C. 1.5 cst 0.01 cst ASTM-D445 PRG 08-Oct*97 DO A 0492BA CONFTDrNTTAl ascojjttE 'JCaimraiortES, 3nc YOUR ON-TIME QUALITY LAB:.. Baltimore, MD 21224 REPORT OF mALYS3S Rep rtno: 9704087 Page 6 of 11 Client: Radian International Sample Id: Submitted samples: DOW-VP-LW-21 -VI5-PHY collected on 18-Sep-97 Laboratory Sample Number 970021042 (410) 633-1800'' (800) GAS-COYN FAX NO. (410) 633-5443 www.gascoyne.com Parameter Residue on ignition Test Results Reporting Limit Method Analyst Date of Analysis <0.01 % 0.01 % ASTM-D 482 PRG 09-Oct-97 Heat of Combustion 6300 BTU/LB 500 BTU/LB ASTM-D 3286 PRG 08-Oct-97 Density of Liquids 1.33 g/cc 0.001 g/cc ASTM-D 4052 PRG 08-Oct-97 Total Halogens(as Cl) 63% 0.05 % ASTM-D808 PRG 07-Oct-97 Viscosity Sample/Test Notes: Viscosity was determined at 21C. 1.6 cst 0.01 cst ASTM-D445 PRG 08-Oct-97 A 049757 conftdfnttai. J&nbarsdorxm, <3nc. 'OUR CN-TIMI QUAUTy LAB:. Baltimore, MD 21224 sss Rep rt no: 9704087 Page 7 of 11 Client: Radian International Sample Id: Submitted samples; DOW-VP-LW-22-V15-PHY collected on 18-Sep-97 Laboratory Sample Number: 970021043 (410) 633-1800 (800) GAS-COYN FAX NO. (410) 633-5443 www.gascoyne.com Parameter Residue on ignition Test Results Reporting Limit Method Analyst Date of Analysis <0.01 % 0.01 % ASTM-D 482 PRG 09-Oct-97 Heat of Combustion 6300 BTU/LB 500 BTU/LB ASTM-D 3286 PRG 08-Oct-97 Density of Liquids 1.33 g/cc 0.001 g/cc ASTM-D 4052 PRG 08-Oct-97 Total Halogensfas Cl) 61 % 0.05 % ASTM-D808 PRG 07-Oct-97 Viscosity Sample/T st Notes: Viscosity was determined at 21C. 1.6 cst 0.01 cst ASTM-D445 PRG 08-Oct-97 DO A 049258 CONFTDFNTTAL %u,#z&xmz ^lahoratortes-, <3ttc YOUR ON-TIME QUAUTY LAB... Baltimore, MD 21224 REPORT OF A5MLYS33 Report no: 9704087 Page 8 of 11 Client: Radian International Sample Id: Submitted samples: DOW-VP-LW-23-V12-PHY collected on 18-Sep-97 Laboratory Sample Number: 970021044 (410) 633-1800 (800) GAS-COYN - FAX NO (410) 633-5443 www.gascoyne.com Parameter Residue on ignition Test Results Reporting Limit Method Analyst Date of Analysis <0.01 % 0.01 % ASTM-D 482 PRG 09-Oct-97 Heat of Combustion 6400 BTU/LB 500 BTU/LB ASTM-D 3286 PRG 08-Oct-97 Density of Liquids 1.33 g/cc 0.001 g/cc ASTM-D 4052 PRG 08-Oct-97 Total Halogens(as Cl) 65% 0.05 % ASTM-D808 PRG 07-Oct-97 Viscosity Sample/Test Notes: Viscosity was determined at 21C. 1.5 cst 0.01 cst ASTM-D445 PRG 08-Oct-97 DO A 049759 OONFTDFNTTAl Page 9 of 11 Report no: 9704087 Client: Radian International Sample Id: Submitted samples: DOW-VP-LW-11-V15-PHY collected on 17-Sep-97 Laboratory Sample Number 970021045 www.gascoyne.com Parameter Residue on ignition Test Results Reporting Limit Method Analyst Date of Analysis <0.01 % 0.01 % ASTM-D 482 PRG 09-Oct-97 Heat of Combustion 6300 BTU/LB 500 BTU/LB ASTM-D 3286 PRG 08-Oct-97 Density of Liquids 1.33 g/cc 0.001 g/cc ASTM-D 4052 PRG 08-Oct-97 Total Halogens(as Cl) 62% 0.05 % ASTM-D808 PRG 07-Oct-97 Viscosity Sample/Test Notes: Viscosity was determined at 21C. 1.6 cst 0.01 cst ASTM-D445 PRG 08-Oct-97 DO A 049760 CONFTDFNTT Al ascajjnc ^lalmratortes, 3tic YOUR ON-TIME QUALITY LAB.'.. Baltimore, MD 21224 REPORT OF AWALY8J Report no: 9704087 Page 10 of 11 Client: Radian International Sample Id: Submitted samples: DOW-VP-LW-12-V13-PHY collected on 17-Sep-97 Laboratory Sample Number: 970021046 (410)633-1800 ' (800) GAS-COYN FAX NO. (410)633-5443 www.gascoyne.com Parameter Residue on ignition Test Results Reporting Limit Method Analyst Date of Analysis <0.01 % 0.01 % ASTM-D 482 PRG 09-Oct-97 Heat of Combustion 6400 BTU/LB 500 BTU/LB ASTM-D 3286 PRG 08-Od-97 Density of Liquids 1.33 g/cc 0.001 g/cc ASTM-D 4052 PRG 08-Oct-97 Total Halogensfas Cl) 58% 0.05% ASTM-D808 PRG 07-Oct-97 Viscosity Sample/Test Notes: Viscosity was determined at 21C. 1.6 cst 0.01 cst ASTM-D445 PRG 08-Oct-97 n0 A 0A9?M conftdfnttal asjco\tng ^CaWrairrrtgg, YOUR Wi-TIMl QUALITY LAB.'.. Baltimore, MD 21224 RIF*? tr AMALY8IIS Rep rtno: 9704087 Page 11 of 11 Client: Radian International Sample Id: Submitted samples: DOW-VP-LW-13-V13-PHY collected on 17-Sep-97 Laboratory Sample Number: 970021047 (410) 633-180C (soo qas-coyn www.gascoyn0.com Parameter Residue on ignition Test Results Reporting Limit Method Analyst Date of Analysis <0.01 % 0.01 % ASTM-D 482 PRG 09-Oct-97 Heat of Combustion 6400 BTU/LB 500 BTU/LB ASTM-D 3286 PRG 08-Oct-97 Density of Liquids 1.33 g/cc 0.001 g/cc ASTM-D 4052 PRG 08-Oct-97 Total Ha!ogens(as Cl) 67% 0.05 % ASTM-D808 PRG 07-Oct-97 Viscosity Sample/Test Notes: Viscosity was determined at 21C. 1.6 cst 0.01 cst ASTM-D445 PRG 08-Oct-97 DO A 049262 CONFTDFNTTAL