Document xjR0w6r08Eg51nBDqGR1w4ejG
ascojjttE ^laboratories, ,3(nc
YOUR ON-TIME QUALITY LAB...
Baltimore, MD 21224 REPORT
Radian International 8501 North Mopac Blvd Austin, TX 78759
(410) 633-1800
(800) GAS-COYN
FAX NO. (410)633-5443
Page 1 of 11
www.gascoyne.com
Report No: 9704087
Attn: Heidi Krall
This report of analysis contains test results for the following samples submitted to Gascoyne Laboratories, Inc.:
Client Sample I.D., DOW-VP-LW-31 -VI9-PHY, 15-Sep-1997 DOW-VP-LW-32-V18-PHY, 16-Sep-1997(1300) DOW-VP-LW-33-V18-PHY, 16-Sep-1997(2000) DOW-VP-LW-21 -VI5-PHY, 18-Sep-1997 DOW-VP-LW-22-V15-PHY, 18-Sep-1997 DOW-VP-LW-23-V12-PHY, 18-Sep-1997 DOW-VP-LW-11 -VI 5-PHY. 17-Sep-1997 DOW-VP-LW-12-V13-PHY, 17-Sep-1997
Sample Type Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid
Lab Sample No. 970021039 970021040 970021041 970021042 970021043 970021044 970021045 970021046
Received by Gascoyne
25-Sep-1997 25-Sep-1997 25-Sep-1997 25-Sep-1997 25-Sep-1997 25-Sep-1997 25-Sep-1997 25-Sep-1997
DO A 049057 OONFTDFNTTAI
YOUR ON-TIME QUALITY LAB!..
Baltimore, MD 21224
Radian International 8501 North Mopac Blvd Austin, TX 78759 Attn: Heidi Krall
(410)633-1800
(800) GAS-COYN
FAX NO. (410) 633-5443
www.gascoyne.com
Page 2 of 11 Report No: 9704087
Client Sample I.D., DOW-VP-LW-13-V13-PHY, 17-Sep-1997
This Report contains the following:
A) Cover Letter B) Test Results C) Chain-of-Custody
Sample Type Liquid
Lab Sample No. 970021047
Received by Gascoyne
25-Sep-1997
All samples were analyzed following EPA protocols and other recognized methodologies as specified in the report. All laboratory Quality Control(QC) data associated with this report are within established control limits unless otherwise noted in this report. Gascoyne Laboratories, Inc. laboratory identification numbers: Maryland :109; Delaware: MD015; Virginia: 00152; New Jersey: 60637; Pennsylvania: 68-339 West Virginia: 9901 (C) and 054; New York: 11158; A2LA: 410.01; AIHA:8885; US Army Corps of Engineers; and EPA ICR: ICRMD003. The analyses specified in this report may or may not be included in the scopes of the above listed certifications. This cover page is an integral part of this report and must be included with all copies of this report.
Report issue date
OO A 049253 GONFTDFNTT Al
(Basca^ne Jlaimrattfmg,
YOUR 0N-TIME QUALITY LAB!..
Baltimore, MD 21224
REPORT OF AWALY8DS
Page 3 of 11
(410) 633-1800
(800) GAS-COYN
FAX NO. (410) 633-5443
www.gascoyne.com
Rep rtn : 9704087
Client:
Radian International
Sample Id: Submitted samples: DOW-VP-LW-31-V19-PHY collected on 15-Sep-97 Laboratory Sample Number 970021039
Parameter Residue on ignition
Test Results
Reporting Limit
Method
Analyst
Date of Analysis
0.01 %
0.01 % ASTM-D 482
PRG 09-Oct-97
Heat of Combustion
6300 BTU/LB 500 BTU/LB ASTM-D 3286
PRG 08-Oct-97
Density of Liquids
1.33 g/cc
0.001 g/cc ASTM-D 4052
PRG 08-Oct-97
Total Halogens(as Cl)
65 %
0.05 % ASTM-D808
PRG 07-Oct-97
Viscosity
Sample/Test Notes: Viscosity was determined at 21C.
1.6 cst
0.01 cst ASTM-D445
PRG 08-Oct-97
DO A 049754 CONFTDFNTTAL
3fnc~
YOUR WI-TIME QUALITY LAB!..
Baltimore, MD 21224
REPORT OF ASH1ALYS3S
Page 4 of 11 Rep rt no: 9704087 Client: Radian International Sample Id: Submitted samples: DOW-VP-LW-32-V18-PHY collected on 16-Sep-97(13:00)
Laboratory Sample Number 970021040
(410) 633-1600 '
(800) GAS-COVN" --'
FAX NO. (410) 633-5443
www.gascoyne.com
Parameter Residue on ignition
Test Results
Reporting Limit
Method
Analyst
Date of Analysis
<0.01 %
0.01 % ASTM-D 482
PRG 09-Oct-97
Heat of Combustion
6700 BTU/LB 500 BTU/LB ASTM-D 3286
PRG 08-Oct-97
Density of Liquids
1.33 g/cc
0.001 g/cc ASTM-D 4052
PRG 08-Oct-97
Total Halogens(as Cl)
58%
0.05 % ASTM-D808
PRG 07-Oct-97
Viscosity
Sample/Test Notes: Viscosity was determined at 21C.
1.5 cst
0.01 cst ASTM-D445
PRG 08-Oct-97
DO A 049255 CONFTOFNTTAl
Bn&cagm( ^Gahrrratirrteg,
YOUR ON-TIME QUAUTY LAB!..
Baltimore, MD 21224 ^EF!RT F AMALYS38
Report no: 9704087
Page 5 of 11
Client: Radian International
Sample Id: Submitted samples: DOW-VP-LW-33-V18-PHY collected on 16-Sep-97(20:00) Laboratory Sample Number 970021041
(410) 633-1800
(800) GAS-COYN
FAX NO. (410) 633-5443
www.gascoyne.com
Parameter Residue on ignition
Test Results
Reporting Limit
Method
Analyst
Date of Analysis
<0.01 %
0.01 % ASTM-D 482
PRG 09-Oct-97
Heat of Combustion
6400 BTU/LB 500 BTU/LB ASTM-D 3286
PRG 08-Oct-97
Density of Liquids Total Halogens(as Cl)
1.33 g/cc
0.001 g/cc ASTM-D 4052
PRG 08-Oct-97
65 %
0.05 % ASTM-D808
PRG 07-Oct-97
Viscosity
Sample/Test Notes: Viscosity was determined at 21C.
1.5 cst
0.01 cst ASTM-D445
PRG 08-Oct*97
DO A 0492BA CONFTDrNTTAl
ascojjttE 'JCaimraiortES, 3nc
YOUR ON-TIME QUALITY LAB:..
Baltimore, MD 21224
REPORT OF mALYS3S
Rep rtno: 9704087
Page 6 of 11
Client: Radian International
Sample Id: Submitted samples: DOW-VP-LW-21 -VI5-PHY collected on 18-Sep-97 Laboratory Sample Number 970021042
(410) 633-1800''
(800) GAS-COYN
FAX NO. (410) 633-5443
www.gascoyne.com
Parameter Residue on ignition
Test Results
Reporting Limit
Method
Analyst
Date of Analysis
<0.01 %
0.01 % ASTM-D 482
PRG 09-Oct-97
Heat of Combustion
6300 BTU/LB 500 BTU/LB ASTM-D 3286
PRG 08-Oct-97
Density of Liquids
1.33 g/cc
0.001 g/cc ASTM-D 4052
PRG 08-Oct-97
Total Halogens(as Cl)
63%
0.05 % ASTM-D808
PRG 07-Oct-97
Viscosity Sample/Test Notes: Viscosity was determined at 21C.
1.6 cst
0.01 cst ASTM-D445
PRG 08-Oct-97
A 049757 conftdfnttai.
J&nbarsdorxm, <3nc.
'OUR CN-TIMI QUAUTy LAB:.
Baltimore, MD 21224 sss
Rep rt no: 9704087
Page 7 of 11
Client:
Radian International
Sample Id: Submitted samples; DOW-VP-LW-22-V15-PHY collected on 18-Sep-97 Laboratory Sample Number: 970021043
(410) 633-1800
(800) GAS-COYN
FAX NO. (410) 633-5443
www.gascoyne.com
Parameter Residue on ignition
Test Results
Reporting Limit
Method
Analyst
Date of Analysis
<0.01 %
0.01 % ASTM-D 482
PRG 09-Oct-97
Heat of Combustion
6300 BTU/LB 500 BTU/LB ASTM-D 3286
PRG 08-Oct-97
Density of Liquids
1.33 g/cc
0.001 g/cc ASTM-D 4052
PRG 08-Oct-97
Total Halogensfas Cl)
61 %
0.05 % ASTM-D808
PRG 07-Oct-97
Viscosity
Sample/T st Notes: Viscosity was determined at 21C.
1.6 cst
0.01 cst ASTM-D445
PRG 08-Oct-97
DO A 049258 CONFTDFNTTAL
%u,#z&xmz ^lahoratortes-, <3ttc
YOUR ON-TIME QUAUTY LAB...
Baltimore, MD 21224
REPORT OF A5MLYS33
Report no: 9704087
Page 8 of 11
Client:
Radian International
Sample Id: Submitted samples: DOW-VP-LW-23-V12-PHY collected on 18-Sep-97 Laboratory Sample Number: 970021044
(410) 633-1800
(800) GAS-COYN -
FAX NO (410) 633-5443
www.gascoyne.com
Parameter Residue on ignition
Test Results
Reporting Limit
Method
Analyst
Date of Analysis
<0.01 %
0.01 % ASTM-D 482
PRG 09-Oct-97
Heat of Combustion
6400 BTU/LB 500 BTU/LB ASTM-D 3286
PRG 08-Oct-97
Density of Liquids
1.33 g/cc
0.001 g/cc ASTM-D 4052
PRG 08-Oct-97
Total Halogens(as Cl)
65%
0.05 % ASTM-D808
PRG 07-Oct-97
Viscosity
Sample/Test Notes: Viscosity was determined at 21C.
1.5 cst
0.01 cst ASTM-D445
PRG 08-Oct-97
DO A 049759 OONFTDFNTTAl
Page 9 of 11
Report no: 9704087
Client:
Radian International
Sample Id: Submitted samples: DOW-VP-LW-11-V15-PHY collected on 17-Sep-97 Laboratory Sample Number 970021045
www.gascoyne.com
Parameter Residue on ignition
Test Results
Reporting Limit
Method
Analyst
Date of Analysis
<0.01 %
0.01 % ASTM-D 482
PRG 09-Oct-97
Heat of Combustion
6300 BTU/LB 500 BTU/LB ASTM-D 3286
PRG 08-Oct-97
Density of Liquids
1.33 g/cc
0.001 g/cc ASTM-D 4052
PRG 08-Oct-97
Total Halogens(as Cl)
62%
0.05 % ASTM-D808
PRG 07-Oct-97
Viscosity
Sample/Test Notes: Viscosity was determined at 21C.
1.6 cst
0.01 cst ASTM-D445
PRG 08-Oct-97
DO A 049760 CONFTDFNTT Al
ascajjnc ^lalmratortes, 3tic
YOUR ON-TIME QUALITY LAB.'..
Baltimore, MD 21224
REPORT OF AWALY8J
Report no: 9704087
Page 10 of 11
Client:
Radian International
Sample Id: Submitted samples: DOW-VP-LW-12-V13-PHY collected on 17-Sep-97 Laboratory Sample Number: 970021046
(410)633-1800 '
(800) GAS-COYN FAX NO.
(410)633-5443
www.gascoyne.com
Parameter Residue on ignition
Test Results
Reporting Limit
Method
Analyst
Date of Analysis
<0.01 %
0.01 % ASTM-D 482
PRG 09-Oct-97
Heat of Combustion
6400 BTU/LB 500 BTU/LB ASTM-D 3286
PRG 08-Od-97
Density of Liquids
1.33 g/cc
0.001 g/cc ASTM-D 4052
PRG 08-Oct-97
Total Halogensfas Cl)
58%
0.05% ASTM-D808
PRG 07-Oct-97
Viscosity Sample/Test Notes: Viscosity was determined at 21C.
1.6 cst
0.01 cst ASTM-D445
PRG 08-Oct-97
n0 A 0A9?M
conftdfnttal
asjco\tng ^CaWrairrrtgg,
YOUR Wi-TIMl QUALITY LAB.'..
Baltimore, MD 21224
RIF*? tr AMALY8IIS
Rep rtno: 9704087
Page 11 of 11
Client: Radian International
Sample Id: Submitted samples: DOW-VP-LW-13-V13-PHY collected on 17-Sep-97 Laboratory Sample Number: 970021047
(410) 633-180C
(soo qas-coyn
www.gascoyn0.com
Parameter Residue on ignition
Test Results
Reporting Limit
Method
Analyst
Date of Analysis
<0.01 %
0.01 % ASTM-D 482
PRG 09-Oct-97
Heat of Combustion
6400 BTU/LB 500 BTU/LB ASTM-D 3286
PRG 08-Oct-97
Density of Liquids
1.33 g/cc
0.001 g/cc ASTM-D 4052
PRG 08-Oct-97
Total Ha!ogens(as Cl)
67%
0.05 % ASTM-D808
PRG 07-Oct-97
Viscosity Sample/Test Notes: Viscosity was determined at 21C.
1.6 cst
0.01 cst ASTM-D445
PRG 08-Oct-97
DO A 049262 CONFTDFNTTAL