Air Conditioning
Unit Heaters and Coolers
?'V
JOHN J. NESBITT, INC.
Philadelphia 36, Pa.
Air Conditioning Fnd'c^S8
JOHN J. NESBITT, INC.
Philadelphia 36, Pa.
NESBITT SILL-LINE RADIATION
NESBITT UNIT HEATERS are designed to circulate large volumes of air at comparatively low temperatures, assuring quick heating.
High-capacity perimeter heating in an
Ratings of Nesbitt Unit Heaters are based on tests made in accordance with
attractive 16-gage wall-hung enclosure
standard test code of Industrial Unit Heater Association and ASHAE.
:m
for use in schools, hospitals, offices, showrooms, etc. Made in five casing
PROPELLER FAN UNIT HEATERS
Btyles with one-piece back panel for true, rigid alignment; seven lengths from 2 ft
to 8 ft; choice of finishes. Full range of accessories and sleeves eliminate on-thejob cutting. Choice of ten heating ele
ments with CODE approved ratings from 2.9 to 12.1 sq ft EDR. Publication 80-1.
At
Featuring universal heating elements of continuous tube design, each size unit gives a comparable range of capacities with either steam or hot water. Made for high temperature drops, low water rates for installation economy. Small physical
size for comparable Btu output saves space. Sturdy steel casings with bakea-on gray-green hammertone finish for lifetime beauty. Flush-to-ceiling mounting permitted by male pipe connections extending through casing rear. Sealed-for-Iife motors in most models. Balanced aluminum fans with large
NESBITT HEATING AND COOLING SURFACE
standard
blade areas assure gradual, quiet, efficient air delivery. Eight
Propeller-Fan Type basic sizes, 24 models, capacities from 15,000 to 335,000 Btu per
SERIES W. Water surface for air-cool
hour. Sound rated within lowest classifications of new Bulletin
ing, dehumidifying or heating. Copper
IS, I.U.H.A. Sound Test Code. Publication 401.
tubes, aluminum of copper fins. Wide range of sizes in three types: Type WD
GIANT BLOWER-FAN UNIT HEATERS
(continuous tube with exclusive freeze-
Large capacity units for: heating and/or ventilating, free
proof drainability.. feature, and sur
delivery or static pressure, steam or water systems. Twelve
face pitched in the casing); Pub. 246.
basic sizes, each with one of three standard steam coils, three
Type WB (continuous tube sections for
distributing-tube coils, or with a single, two, three, or four-
booster-heating or air-cooling relatively
row hot water coil. Air deliveries from 2000 to 28,000 cfm.
small air volumes but without drainability feature) and Type WC (standard Series W cores pitched in the casing; cast iron headers removable cover plates to permit cleaning, single or double serpen tine circuits.) Publication 855.
SERIES H. General blast coil surface
SERIES T. With Trombone-shaped steam-distributing tubes that eliminate stratification and the danger of freezing under modulated valve control. Gives uniform temperatures over the entire capacity range. Ideal for heating and ventilating and for preheating outdoor air. Copper tubes and headers, aluminum
Basic steam ratings; 83,000 to 1,735,000 Btu/hr. Hot water capacities from 50,000 to 2,460,000 Btu/hr, 1800 to 3400 fpm. Control may be STANDARD--periodic fan operation; THERMADJUST--continuous fan operation with thermo
stat-controlled dampers; or VALVE-CONTROLLED--with thermostat controlling steam supply. Horizontal-suspended, wall, inverted or floor-mounted with wide chbioe of cowls, ans, dampers, filters and other accessories. Publication 404-
Giant Blower-Fan Type
tor heating, ventilating, air-condition or copper fins. Type TO with steam and
ing and drying in both high and low- condensate connections at opposite ends,
pressure systems. Copper tubes, alum Type TS with connections at same end.
inum or copper fins. Seven types, full Fin lengths from 12 in. to 120 in. Publica
il range of sizes. Publication 848.
tion 805.
UTILE GIANT UNIT HEATERS
New design features a single, rectangular, wrap-around heating element which can be used on steam or hot water in both vertical and horizontal applications. Wide variety of out lets (adjustable vane, cone deflector, anemostats and hori zontal- or vertical-louvred) simplifies selection of discharge
NESBITT GAS-FIRED UNIT HEATERS
patterns and mounting heights best suited to job requirements.
ii
Modern, attractive direct-fired unit heaters in seven basic models ranging in capacity from 25,000 to 200,000 Btu heat input. Made' of die-formed furniture steel finished in heat-
resistant, baked-on enamel. Low-speed motor equipped with thermal overload protection. Quiet-operating fans; Re formed adjustable louvers. Equipped with automatic con
Little Giant
Dovm-Blow Type
Units can be mounted within one to three inches of the ceiling because piping connections are located on the sides of the units and the motor is removable through the bottom fan outlet. I. U. H. A. rated for both sound and capacity. 34
models offer capacities ranging from 34,000 to 684,000 Btu per hr. Publication 408.
trols and safety pilot. Units are A.G.A. approved and listed
DELUXE CABINET HEATERS
by Underwriter's Laboratories. Publication 880.
The new Series "C" permits complete
flexibility of design and operation. Units
NESBITT BASEBOARD RADIATION
are available for floor mounting, hori
A new approach in baseboard design.
zontal, wall or inverted applications and
Combines an enclosure of unusual beauty
can be installed fully recessed, semi-re
with a heating capacity ample to achieve
cessed or free standing. The discharge
true perimeter heating (4.1 sq ft EDR
or intake can be face, top or bottom--
per lineal ft). CODE approved steam
direct or with ducts. Available in five
and hot water ratings. Copper tube, alu minum fin element. Furniture steel cabi-.
net in 4,5,6,8 ft lengths. Publication 878.
basic sizes--46 basic capacities ranging from 25,000 to 148,000 Btu per hour. For steam or hot water. Publication 403.
Series "C" Cabinet Heater
VijT 116