APPLICATION AND INSTALLATION INSTRUCTIONS
A. GENERAL
_
Formica Fira Retordant Grad* docoretiva laminar* both unsupported, and veneered to"aiDtltoi c*m*nt board using Koppor's Penacolit* G-1124A adhativa or Formica Supar Fast Dry adhosiv* complies with
the llama spread rating requirements of the Notional Building Cod* (1960) covering interior finish materials.
The National Building Code is an advisory document. While it is generally used by Provincial and Munic
ipal authorities in the formulation of building codes in regions under their jurisdiction, many of the
provisions may have been altered to suit, particular regional requirements and standards,
it is recommended that regional authorities or building codas be consulted in areas where Formiea Fire
Retardant laminates are to bo used to determine if Formica ULC listed ratings,and suggested installation instructions meet with local or regional fir* safety design standards.
B. APPLICATION INSTRUCTIONS
.
.
1. Materials -- The basic Formica Fire Retardant decorative grad* construction panel is composed
of 1/16" Formica Fir* Retardent grad* and asbestos cement board reference (ULC file CR301AGuide No. 40 U8.16) the appropriate surface quality, density, and thickness.
Before glueing materials together Formica Fir* Retardent decorative grad* should be conditioned for a minimum of 48 hrs. at rom."-* -ts not less than 70*F, with a relative humidity existing
under shop conditions but not grc. The materials must be bonded It..,-
75%. .Sing rCaoper's penaeolite G--1I24A odhesiv* or Formica
Super Fast Dry adhesive. Panels c! : 1.. shop bonded following adhesive manufacturer's instruc tions. When Formica Super Fast Dry --tesiv* is used bonding should bo don* with nip rolls. On
' sit* application of Formica Fir* Retordant docoretiva grade using contact adhesive is not rec
ommended.
Other non-combustible materials, steel or asbestos gypsum board eon bo used with Formica Fir*
Retordant Grad*. Before using these materials consult local or regional fir* inspectors.
2. Fabrication - The unsupported laminate and basic construction panel may be fabricated by the same methods and equipment used to fobricat* standard decorative Formica. All cutting tools must
be kept sharp and in good condition to prevent laminar* chipping or asbestos board tear out.
Intersecting cuts and cutouts must be cut cleanly with sharp equipment and have radiused corners. All radiused corners should have as large a radius as possible within design limitations but no smaller than 3/8". Edges of all cut-outs must be filed smoothly and be free from chipping and incipient erasing. Git-outs to accomodate light switch boxes, plug boxes ond other fixtures must have sufficient cleoranc* to avoid binding when fixtures are inserted.
3. Application -- Formiea Fir* Retardant Construction panel (as described in B-1)can be used over continuous solid sheathing, directly to woods studs, or furring strips on eertoin applications. Fixing to metal studs is also suitable subject to choice of asbestos board thickness and method of fas tening. The panel may be used over plaster by applying furring strips horizontally or vertically and nailing through the plaster into firm grounds. The panel can also be used on masonary walls by fixing furring stripe by the usual me : J- of plugging ond romsetting.
C. INSTALLATION
Methods used for fastening the basic Fc..
: _-ecant panel to prepared walls depend on the size
of panel, thickness and design of panel to . cppilcc. Normally the installation method will be governed
by the methods used to install asbestos cemt.-.: bocrc.
Fastening is generally by moans of noiis or ccrews at intervals of 12". Noils should penetrate 1" into
solid wood end should not bo driven closer than 3/8" from edge of material. "H" type moulding applied to furring strips, studs, or solid wood backing offers attractive panelling systems and eliminates edge nailing. Mouldings can bo raised or applied flush with the panel surface by taking a rabbet cut along the
panel edge cutting out th* Formica to the proper width ond using "H" moulding of appropriate width and
race thickness.
If moulding are not to bo used th* panel can be fastened to th* wall by first making a rabbet cut 1/2" wide by the depth of the Formica, and then nailing or screwing along th* edge ond a 1" wide contrasting
or similar pattern strip of Formica applied over th* joint using Formica Super Fast Dry adhesive.
'
Th* fallowing Illustrations can be used as a guide for applying Formica Fire Retardant basic wall
rctian panels!
.
I Maximum Recommended Span between Fastening Devices
j Panel thickness in inches
' ' Wall Span in inches
. 3/16
24
l/f 3 07000998
13/Bn
48
! 1/2
48
Wmarp. rpmejfc oia *> sc. u-uit with
at tu ll-etuig conetructtcn an
<F.ormi6a'Lal-
- - sheet should bo aoalied te minimise any tendency of the panel te warp.
/ s
&
laminated plas-tio
A. GENERAL--Formica Fire Retardant Grade is a thermosetting high pressure laminate very similar
in appearance and characteristics to standard 1/16* Formica decorative laminate with the additional feature of fire retardant properties. This grade is designed primarily for those vertical surface application areas where standard 1/16* Formica does not comply with certain building code requirements, specifically flame spread rating.
B. MATERIAL PROPERTIES
1. Formica Fire Retardant Grade decorative laminate is available in 1/16* thickness only.
2. Formica Fire Retardant Grade decorative laminate complies with all performance requirements of NEMA LP2-3.03 for general purpose type decorative laminates.
Specific requirements covered are:
(a) Wear Resistance
' (b) Resistance of Surface to Boiling Water
(c) Resistance of Surface to High Temperature
(d) Resistance of Surface to Cigarette Burns
(e) Resistance of Surface to Steins
(f) Color Fastness
'
(g) Immersion in Boiling Water
(h) Dimensional Change
(i) Flexural Strength, Modulus of Elastic :y and Defection
of Rupture.
(j) Appearance
'
~ .
3. Fire retardant properties
When tested in accordance with U'.c .. -..on' LsOorstories of Canada ULC SUB. C723, "Test
Method for Fire Hazard Classif.c....,
Sliding Materials", (Tunnel Test) Formica Fire
Retardant Grade decorative laminate ithe following official U/L ratings:
(a) Formica Fire Retardant Grade decorative laminate--unsupported
Flame Spread -- 70 Fuel Contributed -- 25 Smoke Density -- over 200
.
'
(b) Formica Fire Retardant Grade decorative laminate veneered to asbestos cement board with Formica Super Fast Dry Contact Cement.
Flame Spread -- 20 Fuel Contributed -- 15 Smoke Density -- 40
(c) Formica Fire Retardant Grade decorative laminate veneered to asbestos cement board with Penacolite G-1124 adhesive (a phenol-resorcinol adhesive manufactured by Koppers Company, Pittsburgh, Pa.)
.
Flame Spread -- 15
Fuel Contributed -- 15 Smoke Density -- 60-90
C. FABRICATION--Formica Fire Retardant Grade decorative laminate may be fabricated by the same methods and equipment used to fabricate standard'decorative Formica.