Document xdyyLkJ2nRYBVMLDk34v6OQyy
The S ciety of the Plastics Industry, Inc.
355 Lexington Avenue New York, New York 10017 (212) 573 9400
00* e car
March 22, 1982
R&S 116245
Dr. T.R. Torkelson Dow Chemical ll.S.A. Health & Environmental Sciences 1803 Building Midland, MI 48640
Dear Dr. Torkelson:
Attached is information on VCM content of Goodrich's PVC resins. Hope it arrives in time to be of some use to you.
Sincerely,
if4^
fraij W. Lichtenberg Assistant Technical Director
FWLrlac
Enc
The BFGoodrich Company Chemical Group
6100 Oak Tree Boulevard Cleveland. Ohio 44131 216-447-6000
mar i 5 WQ2
March 11, 1982
R&S 116246
Ms. Fran Lichtenberg The Society of the
Plastics Industry 355 Lexington Avenue New York, NY 10017
Dear Ms. Lichtenberg:
At Dr. Maury Johnson's request, enclosed is a copy of 5Goodj^ch Bulletin G-62, "Mater^lSafet^JDat^^Geonj^^gjrl gesinSjComooug^." Table ^Jrovx3e^!aEa^^TesT3ua^vinyr cnTorde^ontentiof major types of Geon resins. Section V includes a lengthy discussion about VCM, monitoring require ments, and VCM content of Geon resins.
Thank you for this opportunity to serve you.
Very truly yours
The BFGoodrich Company Chemical Group
JDT/jb
Enc.
cc: R. B. Downey M. N. Johnson
James D. Tanzllli, Manager Product Safety Literature
Issue Date: January, 1981
HFGoOdrich
Bulletin G-62 Second Edition
(Revised)
MATERIAL
SAFETY DATA t
Geon Vinyl Resins, Compounds
3J 0)
116247
ABOUT THIS BULLETIN
The data in this bulletin is applicable to all Geon vinyl resins -- general purpose type, Super EP type, dispersion resins, blending resins, powd .r coating resjns -- and to all grades of rigid, flexible and Geon cellular vinyl compounds. This bulletin is not applicable to Geon latexes nor to Geon CPVC materials.
The data in this bulletin is limited to the safe han dling and use of the PVC polymer itself and to PVC based compounds we manufacture. It does not in clude information on the suitability of PVC for any particular application nor discuss any precautions that may be necessary during product use in service.
The format used to report material safety data infor mation is essentially similar to the U.S. Department of Labor Form OSHA 20 modified to facilitate description of our materials.
USER'S RESPONSIBILITIES
A bulletin such as this cannot be expected to cover all possible individual situations. In addition, the conditions under which our products are processed and used are beyond our control. The products described herein can be hazardous if not processed properly. As the user of Geon vinyls has the responsibility to provide a safe workplace, all aspects of an individual operation should be exam ined to determine if or where precautions, in addi tion to those described herein, are required. Any health hazard and safety information contained herein should be passed on to your customers or employees, as the case may be. BFGoodrtch must
rely on the user of Geon vinyls to utilize the infor mation we have suppli d to develop work practice guidelines and employee instructional programs for the individual operation.
DISCLAIMER OF LIABILITY
As the conditions or methods of use are beyond our control, we do not assume any responsibility and expressly disclaim any liability for any use of this material. Information contained herein is believed to be true and accurate but all statements or sug gestions are made without any warranty, express or implied, regarding accuracy of the information, the hazards connected with the use of the material or the results to be obtained from the use thereof.
GENERAL INFORMATION
This bulletin has been prepared to provide guide lines and appropriate precautions to assist our customers in the safe handling and use of Geon vinyl resins and compounds. BFGoodrich recom mends that, before use, safety personnel and employees handling Geon vinyls read and under stand the information and precautions presented herein.
During processing or post-processing operations involving heat sufficient to cause mass melting, the sum total of the compounding ingredients present may emit vapors and odors irritating to the respira tory tract, eyes and skin. BFGoodrich recommends that Geon vinyls always be used under wellventilated conditions to avoid significant employee exposure.
SECTION I
Manufacturer's Name The BFGoodrich Company, Chemical Group
Address 6100 Oak Tree Boulevard, Cleveland, OH 44131
Telephone Number (216) 447-6000
3J <2
Trademark Geon Vinyls
CP Chemical Name Poly (vinyl chloride), PVC
_k Formula (CHj CHCL)n
OIO)
Chemical Family Vinyl Chloride Homopolymer (With the following excep
tions):
J* 00
Geon 135: Copolymer of vinyl chioride/vinyl acetate Geon 137: Carboxy-modifled vinyl chloride polymer
Geon 138: Copolymer of vinyl chloride/vinyl ester
SECTION II
HAZARDOUS INGREDIENTS
PVC resins contain small but detectable amounts of residual vinyl chloride monomer(VCM), acancer* suspect agent. Extensive product and process im provements have resulted In the reduction of residual vinyl chloride monomer to a very low level in prime grades of major Geon vinyl resins (See Table 1 and read Section V).
Other ingredients, such as stabilizers, lubricants,
plasticizers, and pigments are added with resin to manufacture PVC compounds. The sum total of all ingredients will emit vapors during processing. All possible health effects of these vapors are not known and individual sensitivities will vary. Ex posure may produce acute health effects in some sensitive individuals. The effects relate primarily to eye, nose, and throat irritation. Efficient ventila tion should be provided (read Section VIII) to pre vent significant employee exposure. BFGoodrich recommends that these materials be used under well-ventilated conditions to avoid breathing these vapors.
Solvents No organic solvents are used in the manufacture of Geon vinyl resins. Organic solvents may be us d in the manufacture of stabilizers and other ingre dients, and therefore, be detectable in small amounts in PVC compound.
Carcinogenic Chemicals See Table III.
Heavy Metals A) Resin: No lead, mercury, other heavy metals or
heavy metal compounds are used in the manu facture of Geon vinyl resins. These materials are ubiquitous and trace quantities may be found in the environment.
B) Compound: Geon vinyl compounds contain heavy metal stabilizers generally in amounts less than 5%. These may include organometallics such as tin, lead, cadmium, barium and zinc and metallic salts such as basic lead carbonate and basic lead sulfate.
Plasticizer Geon vinyl flexible (plasticized) compounds will contain polymeric, monomeric or mixed ester plasticizer in amounts generally between 20%-50%. These materials are volatile when heated, and will contribute to the sum total of the vapors released during processing.
Pigments Geon vinyl compounds may contain commonly available pigments based on lead, iron oxide, car bon black, chromium, ultramarines, titanium diox ide, mercadmiums, phthalocyanines, molybdates, quinacridones and other organic or inorganic materials. In cube compound, these pigments are typically bound-up in our manufacturing process and are not expected to create any hazard in han dling or processing. In powder compounds, because of potential dusty conditions, respiratory protection may be required. If conditions exist where dust is possible, the employee should be provided with a suitable NIOSH approved respirator. (See Section VIII. See Table III).
SECTION III
PHYSICAL DATA (Typical data,
not specifications)
Specific Gravity (HiO = 1.0).
R sin:
1.40.
Compound: See Product Data Sheet.
Solubility in Water -- Slight.
Particle Size
Resin:
See Table II
Compound: Cubes measuring approximately 3/16-
inch per side; or powder. Particle size
of powder compound varies due to
compounding ingredients.
Appearance and Odor
Resin:
White powder, practically odorless or
bland odor.
Compound: Pigmented or unpigmented cubical
granules or powder, slight odor.
SECTION IV
FIRE AND EXPLOSION HAZARD DATA
Extinguishing Media Water is most effective. ABC dry powderand prot type air foams are also effective. Geon vinyls would be considered "ordinary combustibles" (NFPA defined Class A). Carbon dioxide is not generally recommended for use on Class A fires as a lack of cooling capacity may result in reignition.
Special Fire Fighting Procedure Self-contained breathing apparatus should be used for fires in which PVC becomes involved. Personnel not having suitable respiratory protection should leave the area to prevent significant exposure to toxic combustion gases.
Decomposition Products
A) When forced to burn, PVC combustion products will mainly be carbon monoxide, carbon dioxide, hydrogen chloride and smoke. Other gases, in cluding aromatics and aliphatics, are present in small amounts. Geon 135 will also contribute minor amounts of acetic acid as gas and smoke.
Inhalation of, or overexposure to, PVC combus tion products and primarily hydrogen chloride will cause irritation of the respiratory tract, eyes and skin. Depending on the severity of exposure, physiological response to inhalation will be coughing, pain, inflammation, edema, and des quamation in the upper respiratory tract. When burned, PVC will have a detectable pungent odor.
The combustion products of PVC, like those from most other natural and synthetic materials, must be considered toxic. Like most conven tional materials including wood, paper and cot ton, the major hazard is carbon monoxide. Carbon monoxide acts as an asphyxiant while hydrogen chloride is highly irritating.
B) Under abnormal processing c nditions (in cluding equipment malfunctions or plug-up) decomposition of PVC compound may occur in an extruder, injection molding machine, or other processing equipment, resulting in a characteristic whitish smoke which will contain hydrogen chloride and vapors from metallic stabilizers and other ingredients. Inhalation will result in irritation of the respiratory tract, eyes and skin resulting in coughing, pain, and inflam mation. Employees involved in removing decom posing materials should be provided with suitable air supplied respirators. Decomposing compound should be removed to a wellventilated area, preferably outdoors, and thoroughly soaked with water. Stand safely back while dousing since water contacting the hot decomposing compound may result in an explosion-like burst of steam.
Refer to Cumulative Supplement June 1977, NIOSH Certified Equipment, NIOSH #77-195, for alisting of NIOSH approved respirators. It can be
R&S 116249
obtained, no charge, from
Publications Dissemination, DTS NIOSH 4676 Columbia Parkway Cincinnati, Ohio 45226
C) During typical break-down and clean-up of equipment after processing, PVC compound may be held at processing temperature for a short period. While this should not result in significant decomposition, it should be under stood that the combined vapors from all ingred ients will be present. PVC compound cannot be held static in processing equipment under high heat or at processing temperature for extended periods of time. Decomposition will occur. Dur ing equipment clean-up operations, avoid inhala tion of fumes. Local exhaust ventilation should be provided to prevent significant employee xposure.
D) Post-processing operations at your workplace or at your customer's workplace involving heat suf ficient to result in polymer breakdown emitting smoke and fumes should always be conducted in a manner to avoid inhalation of fumes. Local exhaust ventilation should be provided to pre vent significant employee exposure.
Unusual Fire and Explosion Hazards The potential dust explosion hazard of PVC has been evaluated by BFGoodrich using the Hartmann Vertical Tube Apparatus developed by the Bureau of Mines. In this test, resin is fluidized in a vertical tube using a stream of air. Ignition is accomplished using a high voltage alternating current spark applied across brass terminals. Research has also been reported by the National Fire Protection Association (NFPA) based on equations using data from a bat tery of tests.
PVC Resin: - Geon vinyl resins representing fine particle size (2 Microns: Geon 121), medium particle size (75 Microns: Geon 141 (140 x 31)and large particle size (130 Microns: Geon 103EPF76) neither ignited nor exploded in a test range of 0.1-2.0 gm/liter concentra tion using standard conditions of test. Fluidization becomes difficult at and above the 2.0 gm/liter level making it impractical to test at greater volumes.
- The NFPA (Fire Protection Handbook,
14th Edition, pg. 3-112) shows "fine"
_ particle size homopolymer PVC resin
jp to have a low order of risk:
(/)
Expiosibility Index
0.1 (Weak)
Ignition Sensitivity 0.1 (Weak)
-i, Explosion Severity <0.1 (Weak)
0ro5 oi o
These data indicate that typical homo polymer PVC resin has a very low
order of explosion risk. As a precau
tion, it is prudent to employ standard
safety measures used in handling
finely divided organic powders.
PVC
- Cub Compound, because of large
C mpound: particle size, does not represent an
explosion hazard.
Powder Compound, because of fine particle size fillers and additives or liquids added to the PVC resin, may have increased dust explosion poten tial. Because of the wide variety of possible ingredient combinations, operations using plasticized or unplasticized powder compounds should be evaluated as the individual situation exists.
- The NFPA (Fire Protection Handbook, 14th Ed., pg. 3-112) reports the follow ing for a PVC (67%)/OOP (33%) mixture: Expiosibility Index 2.9 (Strong) Ignition Sensitivity 3.6 (Strong) Explosion Severity 0.8 (Moderate)
- Implement precautions to control or eliminate likely sources of ignition, such as static build-up. Maintain good housekeeping, notably, ventilation, to prevent accumulation of potentially explosive dust concentrations. Prop erly maintain and operate dust control devices.
Ignition Characteristics (ASTM D-1929) PVC resin has a flash-ignition temperature of about 391 *C (735*F) and a self-ignition temperature of about 454C (850*F). Because PVC polymer con tains chlorine in the molecule, these materials are difficult to ignite and burn slowly. Like all organic materials, PVC is combustible and can be forced to burn by continuous application of intense heat. Like ail combustible materials, protect from open flame and maintain proper clearance when using portabl heat devices, etc. Safely store flammable liquids away from PVC.
Flash Ignition Temperature: The lowest initial temperature of air passing around the specimen at which sufficient combustible gas is evolved to be ignited by a small external pilot flame.
Self-Ignition Temperature: The lowest initial temperature of air passing around the specimen at which, in the absence of an ignition source, ig nition occurs of itself, as indicated by an explo sion, flame or sustained glow.
SECTION V
HEALTH HAZARD DATA
Thresh Id Umit Value None established.
Effects of Overexposure Processing vapors may produce acute health ef fects in some individuals. The effects relate primar
ily t'o eye, nose and throat irritation. Individuals with bronchial asthma and other types of chronic ob structive respiratory disease may develop bronchspasm if exposure is prolonged.
Emergency and First Aid Procedures If irritation persists, remove affected individual from the area. Call a physician. Provide protection before re-entry. If overexposure occurs, leave the area.
Skin Sensitization. Human patch tests conducted with numerous Geon vinyl resins indicate these materials have a low order of toxicity and do not cause skin sensi tization.
Vinyl Chloride Monomer (VCM) By a process called polymerization, vinyl chloride monomer, which is a gas at ordinary temperature and pressure, is converted into polyvinyl chloride (PVC) resin, which is a white powder. A small number of workers exposed for many years to large amounts of VCM gas developed a rare cancer of the liver called angiosarcoma. Ali confirmed VCM re lated cases have been among workers in plants that either manufacture VCM or convert VCM into PVC. OSHA has implemented regulations which also ap ply to PVC because small amounts of residual VCM remain in resins or compounds and potentially may be released into the workplace atmosphere during storage or processing.
VCM Monitoring Requirements Current OSHA regulations require all facilities where PVC is processed (including blends of PVC with other polymers) or fabricated (with heat suffi cient to cause mass melting*) shall be monitored to determine concentrations of ambient VCM in the workplace atmosphere. These regulations require that no employee may be exposed to VCM concen trations greater than 1.0 ppm (part per million by volume) averaged over any eight hour period or 5.0 ppm averaged over any period not exceeding 15 minutes. The action level is 0.5 ppm averaged over any eight hour work day.
Monitoring may be discontinued for any employee only when at least two consecutive determinations, made not less than five working days apart, show ex posures for that employee at or below the action level. REFERTO OSHA REGULATIONS (INCLUDING 1910.1017) FOR COMPLETE DETAILS.
Since small quantities of VCM do remain in PVC resin, we recommend that periodic monitoring pro grams be conducted, if you choose to have monitor ing conducted by an independent laboratory, we suggest that the laboratory be one accredited by the American Industrial Hygiene Association.
"Mass melting" occurs when the entire structure is heated so that the physical integrity and form of the input material is lost.
Places where VCM May C ncentrate With the low level of residual VCM in today's resins and by following the guid lines provided in this bulletin, it is highly unlikely under normal circum stances that anyone engaged in handling or pro
cessing Geon vinyls will be exposed to ambient VCM concentrations above the OSHA "action level."
There are, however, conditions under which VCM may accumulate to measurable amounts in the workplace atmosphere. Since VCM is volatile, it is released from the resin gradually in storage and more rapidly under heat from further processing. Open, handle, and use PVC resin and compound under wel l-ventilated conditions to avoid significant employee exposure.
Areas where VCM might concentrate are: 1) Closed containers such as bulk railcars, bulk
trucks, storage tanks, and drums. Vent th air space above the resin or compound and monitor for VCM; or, provide suitable respiratory protec tion prior to exposure of personnel (See OSHA 1910.1017).
2) Storage areas for bagged or boxed PVC and places where incoming resins and compounds are unloaded, where packages are first opened, and where material is first melted. Provide suit able ventilation.
3) Processing areas such as compound prepara tion; extruding, curing, or coating operations, and other areas where-heat is being applied. Pro vide suitable ventilation.
VCM at levels below 260 ppm reportedly cannot be detected by odor. Suitable test equipment and methods must be used.
Low VCM Content of Geon Vinyls BFGoodrich has implemented continuing technical efforts to reduce the level of VCM in the work atmos phere, the environment, and in PVC resin. Extensive product and process improvements have resulted in General Purpose, EP-type, Dispersion and Mass Polymerized Blending resins with extremely low levels of residual VCM. Residual VCM in majortypes of Geon vinyl resins are presented in Table 1.
Studies in PVC processing and fabricating plants have shown exposures to be below the "action level." With current resins, in combination with ven tilation and work practice programs, It should be possible fora typical processing plant not to have to regulate the area. Compliance with OSHA regula tions requires that a program of initial monitoring be implemented (See OSHA 1910.1017). BFGoodrich recommends that periodic monitoring be con ducted thereafter.
Progress has also been made in reducing residual VCM in suspension grade blending and paste resins. Because of the unique characteristics of blending and paste resins, there is greater technical difficulty in stripping residual VCM without damag ing the polymer. Residual VCM in suspension grade blending and paste resins may result in detectable quantities of ambient VCM above the action level in storage and processing areas of the resin user's plant. The user should monitor personnel periodic ally and implement ventilation and work practice programs to prevent significant employee xposure and to comply with OSHA regulation 1910.1017.
SECTION VI
REACTIVITY DATA
Stability -- Stable. Decomposition Products -- See Section IV. Hazard us Polymerization -- Will Not Occur.
Incompatibility Avoid contact of PVC resin or compound with acetal or acetal copolymers and with amine-containing materials during processing. At processing condi tions these materials are mutually destructive and involve rapid degradation of the products. Thor oughly purge and mechanically clean processing equipment to avoid even trace quantities of these materials from coming in contact with each other. Prevent cross contamination of feedstocks.
SECTION VII
SPILL OR LEAK PROCEDURES
Steps to be taken in case material is released or spilled Sweep, shovel, or vacuum into containers for reuse or disposal. If conditions occur where dust is possi ble, employees should be supplied with NIOSH ap proved respirator. (See Section VIII).
Waste Disposal Method Landfill or incineration in accordance with federal, state, or local regulations. If incinerated, be aware that corrosive hydrogen chloride is generated. Geon vinyl resins and compounds are not defined or designated as hazardous for waste disposal pur poses under the current provisions of the Resource Conservation and Recovery Act. (40CFR261)
SECTION VIII
SPECIAL PROTECTION
Ventilation Exhaust ventilation designed to pull vapors away from workers should be installed at all mixing opera tions, the hot end and feed area of processing equip ment and at cut-off equipment. Ventilation should always be used to prevent routine inhalation of smoke, fumes or vapors from processing or other operations. Other operations to consider include re grind operations, thermoforming, heat sealing, soldering, and curing.
We suggest that you obtain a copy of the NIOSH Recommended Industrial Ventilation Guidelines, GPO #017-033-00136-7. It can be obtained from Superintendent of Documents, U.S. Government Printing Office, Washington, D.C. 20402. There is a fee for this publication ($3.90 as of September, 1980).
Respiratory Protection -- Dust OSHA 1910.1000(e) requires wearing of approved respirator or implementing appropriate engineering controls if airborne concentrations of dust particles exceed 15 mg/m3 of total dust, or 5 mg/m* of respir
able dust. Health authorities recognize respirable dust to be particles 10 microns or smaller in size. Typical particle size for suspension and mass PVC resins is 130-150 microns; blending resins 40-80 microns. Dispersion resins have an average particle size below 10 microns.
Note: While there is no evidence of a substantial risk to health, a British study found a small decrease in breathing capacity for workers who smoked and were exposed to PVC dust. This decrease was about one-seventh of that caused by normal aging and about equal to that expected with a one-pack-a-day cigarette smoker. There was no significant decrease from inhalation of PVC dust by non-smokers. These findings indicate that it is prudent to minimize PVC dust exposure as much as possible.
Other Protection Information 1) PVC resin must be compounded with other ingre
dients. If you purchase PVC resin, the other in gredients you select for compounding purposes may require special consideration, especially respiratory protection. You must determine to your own satisfaction that your techniques, pro cesses and additives comply with applicable regulations. As we cannot be responsible for materials or operations outside of our direct con trol, contact your additive supplier for informa tion regarding specific compounding ingredients you select.
2) Safety glasses are recommended for all indus trial workplaces. Special protective gloves and clothing are not normally required. Wear gloves when handling hot PVC.
SECTION IX
SPECIAL PRECAUTIONS
1) Vapors emitted during processing may condense on exhaust hoods, ductwork or other surfaces. Avoid skin contact with condensate during clean up operations. Condensate may contain contam inants which may be toxic. Rubber gloves should be worn when cleaning condensate from exhaust hoods and other surfaces.
2) Observe good rules of personal industrial hygiene. Wash hands prior to eating, smoking, or using toilet facilities. Do not store or consume food in processing areas. Do not use processing equipment to heat food.
3) The process of regrinding PVC scrap for reextrusion or waste disposal generally results in substantial heat. Cool regrind before placing it in containers. The excellent insulating quality of PVC will prevent heat in the center of a container from escaping, potentially resulting in slow ther mal decomposition of the material. This may not only render the product unsatisfactory for further processing but also result in fumes and vapors from all ingredients being released into the work place atmosphere which can cause irritation of the respiratory tract, eyes and skin.
4) Remove PVC resin or compound from walkways and floors to prevent slippery footing.
R&S 11625,
SECTION X
TRANSPORTATION INFORMATION
For transportation purposes, Geon vinyl resins and compounds are not defined or designated as hazardous materials by the U.S. Department of Transportation under Title 49 of the Code of Federal Regulations, 1979 edition.
JJ 0 co otton> co
TABLE 1 RESIDUAL VINYL CHLORIDE MONOMER (RVCM) IN MAJOR TYPES OF GEON RESIN AND COMPOUND
DESCRIPTION
INHERENT VISCOSITY
ASTM DESIGNATION D-1243
CLOSEST CLASSIFICATION
ASTM 0-1755
AVERAGE AMOUNT OF RVCM
(PPM) PRIME GOODS
TYPE
IN RESIN
COMPOUNO PRIOR TO
USED IN COMPOUNDING IN COMPOUND
AVERAGE AMOUNT OF RVCM (PPM)
OFF-GRADE RESIN* TAILINGS
(B, C A E-GRADES)
Suspension Resins Homopolymers 1. High Molecular Weight 2. Med. Molecular Weight
3. Low Molecular Weight Emulsion Resins Dispersion
102EP F-5 30 103EP F-76 92 110x334
121,178 '
1.13 1.02 0.92 1.00 0.68
1.20
GP6-15443 GPS-15443 GP4-16043 GP5-15543 GP1-16243
Not Applicable
Rigid Flexible Rigid Flexible Rigid
None
< 1 <1 1 <1 1 <1 1 <1 3 <3
5 Not Applicable
<50 <50 <50 <5 <5
<20
Mass Resins 1. Med. Molecular Weight
2. Low Molecular Weight
83 88 85
221 141 142
GROUND RESIN
(B-GRADE ONLY)
0.92
GP4-16043
Rigid
<10
<5
<50
0.96
GP5-15443
Flexible
<10
<5
<50
0.70
GP2-16243
Rigid
<20
<10
<50
0.76
GP2-46043
None
<10 Not Applicable
<50
0.84
GP3-46343
None
<10 Not Applicable
<50
0.76
GP4-46243
None
<10 Not Applicable
<50
NOTE: < means "less than.''
< means ``equal to or less than. ''
'Downgraded resin (B & C grade) Same as prime.
TABLE II
Particle Size of Geon vinyl resins:
]% Through Mesh Screen
99% Through 325 Mesh Screen
30 83 85 86 88 80x24 80x25 80x26 212 102EP 103EP F-76 110x334 110x352 141 142
221
121 123 124
125 135 137 138 171 178 179 184
186
100% Through 30 Mesh Screen
92 99
95% Through 100 Mesh Screen
214 213
C0
TABLE III CARCINOGENIC COMPOUNDS
None of the following substances are used in the manufacture of Geon vinyls nor are they anticipated by-products in our production process. Although the following materials do not represent any official govern mental list nor all possible carcinogenic compounds, they do represent specific substances our customers have typically inquired about.
Some of these materials are ubiquitous and trace quantities may be found in the environment or as impurities in ingredients used in compounding.
Asbestos
OSHA 1910.1001
Coal tar pitch volatiles 4-Nitrobiphenyl
.1002 .1003
alpha-Naphthylamine
.1004
4,4' -- Methylene (bis) 2-chloroamline
.1005
Methyl Chloromethyl Ether
.1006
3,3'-- Dichlorobenzidine (and its salts)
.1007
bis-chloromethyl ether beta -- Naphthylamine
.1008 .1009
Benzidine
.1010
4--Aminodiphenyl
.1011
Ethyleneimine
.1012
beta-Propiolactone
.1013
2-Acetylaminofluorene
.1014
4 -- Dimethylaminoazobenzene
.1015
N-Nitrosodimethylamine
.1016
Benzene
.1028
Polybrominated biphenyls
Polychlorinated biphenyls*
EPA (40 CFR Part 761)
'Polychlorinated biphenyls (PCB) may be present as impurities in cer tain phthalocyanine and diarylide pigments. Our suppliers have notified us that the pigments we purchase comply with the 50 ppm maximum allowable limit found in the EPA final rule to be published under Title 49 of the Code of Federal Regulations, Part 761.
ilFG odrich
Chemical Group
The BFGoodrich Company Chemical Group
6100 Oak Tree Boulevard Cleveland, Ohio 44131 216-447-6000
.
1
Sales Offices
CLEVELAND AREA
Suite 300 7550 Lucerne Or. MIDOLEBURG HGTS., OH 44130
216-447-6000
KANSAS CITY AREA 1000 Blue Ridge Tower 4240 Blue Ridge Boulevard KANSAS CITY, MO 64133 616-353-6440
ATLANTA AREA
Suite 535 2700 Cumberland Parkway N.W. ATLANTA, GA 30339 404-434-7761
LOS ANGELES AREA
Suite 970 Wilshire Centre 3055 Wilshire Boulevard LOS ANGELES, CA 90010 213-386-7436
BOSTON AREA
PHILADELPHIA AREA
385 Elliot Street
200 Office Center
NEWTON UPPER FALLS, MA 02164 275 Commerce Drive
817-332-2700
FORT WASHINGTON, PA 19034
CHICAGO AREA
215-64345805
715 Oak Brook Executive Plaza
CANADA
1301 West 22nd Street
409 Weber Street, Weat
OAK BROOK. IL 60521
KITCHENER, ONT., Canada
312-654-4700
519-742*3641
DETROIT AREA
Suite 207 30200 Telegraph Road BIRMINGHAM,. Ml 48011
313*357-3939
INTERNATIONAL DEPARTMENT 6100 Oak Tree Boulevard CLEVELAND, OH 44131
Cable Address: GOODRICHCHEM Telex: 980427 goodchem idpc
R&s 116254
The information contained herein is believed to be reliable, but no representations, guarantees or warranties of any kind are made as to Its accuracy, suitability for particular applications or the results to be obtained therefrom. The infor mation is based on laboratory work with small-scale equipment and does not necessarily indicate end product perfor mance. Because of variations in methods, conditions and equipment used commercially in processing these materials, no warranties or guarantees are made as to the suitability of tne products for the applications disclosed. Full-scale testing and end product performance are the responsibility of the user. BFGoodrtch shall not be liable for and the customer assumes all risk and liability of any use or handling of any material beyond BFGoodrich's direct control. THE SELLER MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANT1ES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Nothing contained herein is to be considered as permission, recommendation, nor as an inducement to practice any patented invention without permis
sion of the patent owner.
b'
Issue Date: January, 1981
IIFG odrich
G-62 Supplement
MATERIAL SAFETY
DATA SHEET
Geon Vinyl Resins, Compounds
<rjo> Ul
R&S
The data in this bulletin is applicable to ail Geon vinyl resins -- general purpose type, Super EP type, dispersion resins, bl ndlng resins, powder coating resins --
WE RECOMMEND POSTING THIS SUPPLE
and t ail grades of rigid, flexible and Geon cellular vinyl compounds. This bulletin is not applicable to Geon latexes nor to Geon CPVC materials.
SECTION I
Manufacturer's Name The BFGoodrich Company, Chemical Group Address 6100 Oak Tree Boulevard, Cleveland, OH 44131
pj Telephone Number (216) 447-6000
(/) Trademark Geon Vinyls
-l Chemical Name Poly (vinyl chloride), PVC Formula (CH2 CHCL)n
Chemical Family VinyhChJoride Homopolymer (With the following exceptions):
o> Geon 135: Copolymer of vinyl chloride/vinyl acetate Geon 137: Carboxy-modified vinyl chloride polymer Geon 138: Copolymer of vinyl chloride/vinyl ester
SECTION II
PVC Resin
HAZARDOUS INGREDIENTS
PVC Compound
For additional information read
BFGoodrich Bulletin G-62, Second Edition (Revised)
1) Residual vinyl chloride monomer.
1) Residual vinyl chloride monomer.
Section V and Table 1
2) Heavy metal stabilizers.
3) Monomeric, polymeric or mixed ester plasticizer in flexible compound.
Section II Section II
4) Pigments based on lead, chromium, mercadmiums, iron oxides or other organics or inorganics.
Section II and Table III
NOTE Vinyl chloride (VCM) is an OSHA regulated material (REFER TO OSHA Section V 1910.1017 FOR COMPLETE DETAILS). Current OSHA regulations require that no employee may be exposed to VCM concentrations greater than 1.0 ppm averaged over any eight hour period or 5.0 ppm averaged over any period not exceeding 15
minutes. All facilities where PVC is processed or fabricated (with heat sufficient to cause mass melting) shall be monitored to determine concentration of ambient
VCM in the workplace atmosphere.
SECTION III
PHYSICAL DATA (Typical data, not specifications)
Specific Gravity (HiO = 1.0).
Resin:
1.40.
Compound: See Product Data Sheet.
Solubility in Water -- Slight
Particle Size
Resin:
Refer to Bulletin G-62.
Table II
Compound: Cubes measuring approximately 3/16-inch per side; or powder of
variable particle size due to compounding ingredients.
Appearance and Odor
Resin:
White powder, practically odorless or bland odor.
Compound: Pigmented or unpigmented cubical granules or powder, slight odor.
SECTION IV
FIRE AND EXPLOSION HAZARD DATA
Flash Ignition(ASTM D-1929)735*F.
Self-Ignition(ASTM D-1929)850*F. Section IV
Extinguishing Media
Section IV
Water. ABC dry powder. Protein type air foams. Carbon dioxide may be ineffective
due to a lack of cooling capacity which may result in reignition.
Special Fire Fighting Procedures
Section IV
Wear self-contained breathing apparatus to prevent inhalation of combustion gases.
Unusual Fire and Explosion Hazard
Sect! n IV
PVC powder compound, especially plasticized powder compounds, may have dust
explosion potential due to compounding ingredients. Control or eliminate likely
ignition sources. Prevent accumulation of potentially explosive dust concentra
tions. Ventilate well.
ENT ON THE EMPLOYEE BULLETIN BOARD
SECTION V HEALTH AND HAZARD DATA
Threshold Limit Value -- None established. Effects of Overexposure Processing vapors may produce acute health effects in some individuals. The ef fects relate primarily to eye, nose and throat irritation. Individuals with bronchial asthma and other types of chronic obstructive respiratory diseases may develop bronchspasm if exposure is prolonged. Emergency and First Aid Procedures If irritation persists, remove affected individual from the area. Call a physician. Pro vide protection before re-entry. If overexposure occurs, leave the area
R&S 116257
SECTION VI REACTIVITY DATA
Stability -- Stable.
Incompatibility (Materials to avoid)
Section VI
In processing equipment, avoid contact of PVC resin or compound with acetal or
acetal copolymers or with amine containing materials. At processing conditions
these materials are mutually destructive and involve rapid decomposition.
Hazardous Decomposition Products
Section IV
CO, COi, HCI, and (in small amounts) aromatic and aliphatic hydrocarbons. Geon
135 will also contribute minor amounts of acetic acid as gas and smoke.
Hazardous Polymerization -- Will not occur.
SECTION VII SPILL OR LEAK PROCEDURES
Steps to be taken if material is released or spilled
Section VII
Sweep, shovel, or vacuum into containers for reuse or disposal.
Waste Disposal Method
Sanitary landfill or incineration in accordance with Federal, state or local regula
tions. Not hazardous for waste disposal per Federal regulations (40 CFR 261).
SECTION VIII
SPECIAL PROTECTION INFORMATION
Respiratory Protection -- Dust If conditions exist where dust is possible, wear NIOSH approved respirator.
Section VIII
Ventilation
Section IV, Section VIII
Exhaust ventilation designed to pull vapors away from workers should be installed
at all operations capable of creating dust, fgmes or vapors.
Other Protection
Section IX
1) Rubber gloves should be worn when cleaning condensate from exhaust hoods
and other surfaces to prevent skin contact.
2) Safety glasses.
SECTION IX SPECIAL PRECAUTIONS
1) Open, handle and use Geon vinyls under well-ventilated conditions.
Section IV, V
2) Avoid breathing fumes.
3) Do not store or consume food in processing areas. Do not use processing equip
ment to heat food. Wash hands prior to eating, smoking or using toilet facilities.
4) Cool regrind before placing in containers to prevent decomposition.
5) Keep PVC resin and compound off the floor to prevent slipping.
SECTION X
TRANSPORTATION INFORMATION
For transportation purposes, G on vinyl resins and compounds are not defined or designated as a hazardous material by the U.S. Department of Transportation under Title 49 of the Code of Federal Regulations, 1979 edition.
1IFG drich
' Chemical Group
The BFGoodrlch Company Chemical Group
6100 Oak Tree Boulevard Cleveland, Ohio 44131 216-447-6000
4
Sales Offices
CLEVELAND AREA Suite 300 7550 Lucerne Dr, MIDDLEBURG HGTS., OH 44130 216-447-6000
ATLANTA AREA Suite 535 2700 Cumberland Parkway N.W. ATLANTA, GA 30339 404-434-7761
BOSTON AREA 385 Elliot Street NEWTON UPPER FALLS, MA 02164 617-332-2700
CHICAGO AREA 715 Oak Brook Executive Plaza 1301 West 22nd Street OAK BROOK, IL 60521 312- 654*4700
DETROIT AREA Suite 207 30200 Telegraph Road BIRMINGHAM, Ml 48011 313- 357-3939
KANSAS CITY AREA 1000 Blue Ridge Tower 4240 Blue Ridge Boulevard KANSAS CITY, MO 64133 816-353-6440
LOS ANGELES AREA Suite 970 Wllshire Centre 3055 Wllshire Boulevard LOS ANGELES, CA 90010 213-386-7436
PHILADELPHIA AREA 200 Office Center 275 Commerce Orive FORT WASHINGTON, PA 19034 215-643-6805
CANAOA 409 Weber Street, West KITCHENER, ONT,, Canada 519-742-3641
INTERNATIONAL DEPARTMENT 6100 Oak Tree Boulevard CLEVELAND, OH 44131 Cable Address: GOODRICHCHEM Telex: 980427 goodchem idpc
USER'S RESPONSIBILITY A bulletin such as this cannot be expected to cover all possible individual situations. As the user of Geon vinyls has the responsibility to provide a safe workplace, all aspects of an individual operation should be examined to determine if or where precautions, in addition to those described herein, are required. Any health hazard and safety information contained herein should be passed on to your customers or employees, as the case may be. BFGoodrlch must rely on the user of Geon vinyls to utilize the information we have supplied to develop work practice guidelines and employee instructional programs for the individual operation.
Disclaimer of Liability As the conditions of use are beyond our control, we do not assume any responsibility and expressly disclaim any liability for any use of this material. Information con tained herein is believed to be true and accurate but all statements or suggestions are made without any warranty, express or implied, regarding the accuracy of infor mation, the hazards connected with the use of the material or the results to be obtained from the use thereof. Compliance with all applicable federal, state and local laws and regulations remains the responsibility of the user.
The information contained herein is believed to be reliable, but no representations, guarantees or warranties of any kind are made as to Its accuracy, suitability for particular applications or the results to be obtained therefrom. The infor mation is based on laboratory work with small-scale equipment and does not necessarily indicate end product perfor mance. Because of variations in methods, conditions and equipment used commercially in processing these materials, no warranties or guarantees are made as to tne suitability of the products for the applications disclosed. Full-scale testing and end product performance are the responsibility of the user. BFGoodrlch shall not bo liable for and the
J3 customer assumes all risk and liability of any use or handling of any material beyond BFGoodrictVs direct control. THE & SELLER MAKES NO WARRANTIES, EXPRESS OR IMPUED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WAR (/) RANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Nothing contained herein is to be
considered as permission, recommendation, nor as an inducement to practice any patented invention without permis sion of the patent owner.
Orol ui
09
Litho U.S.A.
8101-SPM