Document xd58wzkVVvpXVpa9kVjwOarZ6
FILE NAME DuPont DUP DATE 1968 April 5
DOC DUP058
DOCUMENT DESCRIPTION Memo to Field Project Managers RE Safety -
Dust Control
*
Semveae
-_
-
. . een
PONT
NEMOURS
DE WILMINGTON NEMOURS PONT E. 1. DU PONT ExhDi ELAWARE
COMPANY
COMPANY
DELAWARE
0
19694
WILMINGTON WILMINGTON DELAWARE
\-
MME E .
ra
CC
OW" '
-
ae
Employee Rel Nemours
G.J.Stopps M.D. Employee Rel Haskel
E.C.Jones E.C.Jones Purchasing Louviers
F.H.Mackie Engg B.B.Lewis B.B.Lewis
Constr Louvfniers
.
ENGINEERING DEPARTMENT
oo r
Lo
eo
held
Asbestosis DEC
DEC
DEC
qj
oe
ree
~
Asbestosis
Asbestosis Soot
Asbestosis
Asbestosis Asbestosi
re Asbestosis
AsbestosisAsbestosisAsbestosis oN
"
J.C.Lang
T
"
"
nr
R.K.Mason
7
*
"
W.C.Weaver
"
R.J.Ham
.
"
"
C.J.Lawrence
W.H.Zane Louviers
J.R.Allen
Site Safety Supervisor Constr
-
April 1968 +
FIELD PROJECT MANAGERS -
~~ -
C. W. S.
J. J.
A. D. C. S. W. S. H. S. W. G. M. W. W. C. K. G. R. H. R. G. J. K. W. A.
BAYLIS ASHTABULA'
BRIGGS BEAUMONT BELL BREVARD DAY CAPE FEAR ANDERSON CHAMBERS WORKS FREE CHATTANOOGA STANTON JR CIRCLEVILLE HARRIS COLUMBUS SHOPS HARTNETT JR EAST CHICAGO MANNEAR FLORENCE CAUGHMAN JR HOUSTON
'
DAVIS KINSTON STERNBERGER LOUISVILLE ADDISON MARTINSVILLE SAMANS MAY
SAFETY - DUST CONTROL
A.
W. H. W. F. E. H. E. R. S. R. S. G. J.
S. TRUMPORE MEMPHIS
BLAKE MOBERLY F. REDMILE OLD HICKORY S. LEWIN PARLIN H. FOWLER AFPM PONTCHARTRAIN M. VASS SABINE RIVER J. FEINEN SAVANNAH RIVER K. DRAWDY SEAFORD A. MINIARD SPRUANCE V. HINSON VICTORIA L. SPITZ WASHINGTON WORKS KREWATCH WAYNESBORO E. BARLOW JR WILM AREA R. BALDER MGR WILM SHOPS
Industrial work producing airborne dust particle contamination is
recognized as a primary contributor to employee health problems
The ability of the medical profession in identifying the personal respiratory disease of asbestosis and the establishing of the cause to be due to extended exposure to asbestos dust have created a serious industrial concern Federal and State legislation is being enacted
to place the burden of proof on employer for continuous conformance with Governmental Industrial Hygienists established Threshold
Limit Values for specific materials The employer's problem becomes
acute when employment medical examinations are not required for oe
the employees
fs
oo
With the mentioned responsibility in mind to assure
;
atmospheric conditions which health problems when working
the Construction Division is
will not contribute to the employees
with asbestos fiber containing materials initiating the following permanent air
quality control program to be effective June 1 1968
0012090129
Environmental air monitoring shall be conducted to provide quantitative data for site evaluation of dust control efficiency and document air quality analysis needed to demonstrate conformance with established Threshold Limit Values TLV
2 The Threshold Limit Value for total dust count shall be
500,000 particles per cubic ft of air
2 Personnel monitoring will be conducted in the insulation shops on site locations One employee will be requested to wear the air sampler one eight day each month
Trained site safety personnel shall be responsible for the control operation and adjustment of the air sampling instrument recording required technical data associated with the air sample mailing of air sample to laboratory for analysis and compiling records of analysis reports
When soliciting participation participation in the air monitoring program
craft supervisiaonnd Safety Safety Engineer should anticipate who
will be involved in work whichwhich will produce the greatest dust exposure for what day of that that month
The personnel air sampling instrument used shall be a Universal Industrial Equipment Co. Millipore filter
Model 440B qualified for explosion hazard areas air
sampler The filter used shall be a .8 micron pore
. size Millipore Cat No. MAWG 037 AO Type AA in plastic
holder This equipment will be assigned to the sites where
air monitoring is required by the Division Safety Office
The filter in plastic holder upon completion of air sampling shall be mailed by the site Safety Engineer to Morton Corn Graduate School of Public Health University of Pittsburgh Pittsburgh Pennsylvania 15213 attention Felix Stein A phase microscopy analysis of submitted sample will be made and a report submitted to the site and the Division Safety Office indicating a fibers below 5 micron length b fibers above 5 micron length and c total number of particles Reports indicating total particle count to be approaching or above the TLV will require determining cause of condition and taking
corrective action to reduce particle count After improvement has been applied a second eight sample
shall be conducted analyzed and documented
Atmospheric Dust Control
The application of the following
conformance with the established
emission control
recommendations should demonstrate
dust TLV and provide effective dust
001296 001296
eee
ow
Yuwwsew
wee
1 Materials containing Crocidolite asbestos fiber shall not be purchased or accepted for use Materials containing Chrysotile and Amosite asbestos fibers are acceptable for use
2 The pressure spray application of materials with any per cent
of asbestos fiber content shall be eliminated
equipment 3 All power tool and
operations shall be isolated
from other shop facilities and fabricating operations
4 All power shop equipment shall when operated have installed exhaust ventilation of sufficient capacity to remove dust particles at point of origin Exhausted dust particles shall be collected by an effective collector system which
will not allow vent of dust particles to the atmosphere
5 Present controlled shop cleanliness programs shall be expanded A vacuum cleaner should be used in lieu of broom sweeping to remove dust particles from shop equipment work tables ledges floors etc.
6 A controlled materials handling program should be adopted to eliminate the emission of dust for example when opening and removing materials from shipping cartons or in the
handling and mixing of asbestos cements
Respiratory Protection
Severe or isolated conditions may require that respiratory protective devices be used Consideration should be made for adequate protection of people in adjacent areas to the work location producing this condition A supplied air respirator or a filter respirator manufactured by Mine Safety Appliance Co. Pittsburgh Pa Model Dustfoe 77 with filter number BM 21 97
should be used
Your usual cooperation is anticipated in administering these dust
controls
CONSTRUCTION DIVISION
--
K. E. Keuper
Division Safety
Superintendent
dlm
091 0912 290 9 091290 0 0912 091299 0 0
001897 001897