Document xMgNGVna9gOpvaX4d8r4DRxb
FROM E. E. RUMBERGER PITTSBURGH OFFICE
TO
1982 February 16
RE: ASBESTOS REPLACEMENT
The attached Asbestos Replacement Report is being distributed to plant Department Managers and Superintendents for Engineering, Procurement, Safety, Environmental Control and Industrial Hygiene. It comments on successful and unsuccessful substitutes for asbestos.
Considerable progress has been made in the plants over the past two years in implementing safer substitute materials. This report should be helpful to you in knowing the results of the experiences at the other plants. It might also serve as a useful guide to be used in your next staff meeting to explore your success in making your plant as free from asbestos-containing materials as possible.
We are asking that plant Engineering and Procurement Managers keep us advised of their results in seeking safer substitute materials. This will permit us to share the information throughout the plants. The very worthwhile efforts being made in the plants are much appreciated.
E. E. RUMBERGER
EER:mlf
Distribution: Operations and Works Managers
cc: Engineering Managers Procurement Managers Safety Managers - Domestic and International Environmental Control Contacts Industrial Hygienists - Domestic and International
J. H. Sloane, Pittsburgh Office - 20 T. J. Sherman, Pittsburgh Office - 20 F. J. McGrath, Pittsburgh Office - 20 P. R. Atkins, Pittsburgh Office - 7 J. C. Fussell, 4th Floor - William Penn Hotel P. A. Haas, Pittsburgh Office - 20 J. M. Me Collum, 3rd Floor - William Penn Hotel G. F. Leymeister, Pittsburgh Office - 19 C. E. Rhodes, Pittsburgh Office - 19 R. E. Edgington, Pittsburgh Office - 19
UJ ALCOA
ARD 003551
Page 2 1982 February 16
Distribution: (Con't)
.
M. J. Caprio, Pittsburgh Office - 19
V. R. Scorsone, Pittsburgh Office - 27
G. B. Scott, Pittsburgh Office - 23
E. B. Perry, Pittsburgh Office - 23
H. G. Reavis, Pittsburgh Office - 23
J. R. Clark, Pittsburgh Office - 23
R. J. Hosfeld, Pittsburgh Office - 23
R. D. Hornbeck, Pittsburgh Office - 30
K W. Perry, Pittsburgh Office - 24
R. R, Hoffman, Pittsburgh Office - 30
E. M. Kasody, Pittsburgh Office - 28
W. Turbeville, Pittsburgh Office - 28
C. R. Gillespie, Cleveland Works
R. C. Rawe, Lafayette Works
R. A. G. Vines, Massena Operations
W, C. Keith, Corona Works
J. W. Martin, Lancaster Works
N. W. Nielsen, Pittsburgh Office - 18
J. B. Geshay, Pittsburgh Office - 23
H. S. Evans, Pittsburgh Office - 24
P. L. Abernnethy, Jr., Pittsburgh Office
R. Banks Smith, Pittsburgh Office - 29
H. L. Johnson, Pittsburgh Office - 14
C. P. Fletcher, ATC-C
L. K. Hudson, ATC-C
N. Jarrett, ATC-C
P. R. Bridenbaugh, ATC-C
J. D. Dowd, ATC-C
R. E. Spear, ATC-C
Industrial Hygiene Technical Bulletin
NO. 82-3
Date: 1982 February 16
RE: ASBESTOS REPLACEMENT
The Asbestos Replacement Program was initiated a number of years ago as a result of the health hazards associated with handling asbestos and asbestos-containing materials. The program is a cooperative effort between Production, Engineering, Procurement, Research, Safety and Industrial Hygiene at the plant and corporate levels. It continues to be Alcoa's objective to replace all asbestos with safer substitutes whenever possible.
The only exception is that we do not encourage the immediate removal of affixed asbestos insulation so long as it is in good condition. When it does become necessary to replace worn asbestos-containing materials, safer substitutes should be used. When asbestos is being removed, proper precautions must be taken to protect employees from inhaling asbestos fibers.
Considerable progress has been made in the past two years toward making Alcoa plants asbestos free. The attached report summarizes plant experiences and identifies successful substitutes. It also identifies unsuccessful products that have been tested and failed. The report contains sections on General Applications, Potroom Use, Carbon Ba'ke Use, Wire, Rod and Bar Use, and a List of Asbestos Replacement Manufacturers. This report should benefit each plant based on the experience in other plants.
To continue to coordinate these efforts, it is important that Engineering and Procurement at each plant copy the Corporate Industrial Hygiene Division on all efforts made towards asbestos replacement . . . whether positive or negative results occur.
Please review this present status report and advise us of any new experiences at your location. If we can be of any further assistance, please let us know.
SCOTT M. ANDERSON SMA:mlf Distribution: See Page 2
E! ALCOA
ARD 003553
INDUSTRIAL HYGIENE TECHNICAL BULLETIN 82-3 Page 2 1982 February 16 Distribution: Operations and Works Managers Engineering Managers Procurement Managers Safety Managers - Domestic and International Environmental Control Contacts Industrial Hygienists - Domestic and International Industrial Hygienists - Other Industrial Hygienists - Pittsburgh Office and ATC Attachment
ARD 003554
ASBESTOS REPLACEMENT PROGRAM
Contents
General Applications Belting --Block or Brick -- Brake Linings Cement Patch Cloth and Paper -- Gloves -- Marinite Pump Packing Rope -- Tubing Tape Thermocouple Wire
Potroom Use Cradle to Pot Shell Insulation Superstructure Foot Insulation Pot Cover Insulation Walkway Grating Insulation Bus Insulation -- Pot Exhaust Duct Exhaust Duct Gaskets -- Siphon Gaskets Ladle and Ladle Lid Seal -- Insulated Electrical Wire
Carbon Bake Use Exhaust Duct Manifold Gaskets
Wire, Rod and Bar Jarke Rack Liners
Asbestos Replacement Manufacturers
Page 1 1 2 3 4 5
6 6 7 8 9 10 11
12
12 13
ARD 003555
ASBESTOS REPLACEMENT PROGRAM GENERAL APPLICATIONS
1982 February 16
Material & Use
Belting for Drip Casting
Replacement Status Fiberseal Fabric was tested and found to be inadequate.
Block or Brick for furnaces
Ceramic fiber refractory block is an acceptable substitute. There are no asbestos products currently being installed in melting furnaces, holding furnaces, or heat-treat furnaces.
Brake Linings
A possible (but untested) replacement for asbestos brake linings is RF-28-3D Truck Blocks (4602-FF) from Limpco Manufacturing in Greensville, PA.
Cement Patch for Boiler Maintenance
Two grades:
1. Hydraulic-setting cement - contains mineral wool and Portland Cement; temperature range up to 1000F.
Suppliers:
a) Johns-Manville "375" b) Keene Corporation "Super Powerhouse" c) 48 Insulation "Quick-Set Cement"
2. High-Temperature Grade - contains mineral wool; temperature range 1000F to 1900F.
Suppliers:
a) Johns-Manville "360" b) Keene Corporation "Super 1900" c) 48 Insulation Super "48"
ARD 003556
1982 February 16
Material & Use
Cloth and Paper for Insulation and Welding Protection
ASBESTOS REPLACEMENT PROGRAM
(Page 2)
Replacement Status
Cloth substitutes include: Pyrotek Fabrics, Refrasil, Nor-Fab, Kelnit Welding Blankets
Paper Substitute: Johns-Manville - Cerawool Paper (Note: Paper should not be used for welding protection.)
Gloves
Flame-resistant terrycloth gloves can be used for temperatures up to 700F. Some substitutes successfully used at ATC include Kevlar Mittens (up to 400F) and Kevlar Gloves (up to 900F). These products are available from Kranso Glove & Mitten, Milwaukee, or A-Best Products, Cleveland. Other products are Kelnit 29, Keller Gloves, Pyrotex, Textoglass Gloves, and Pre-ox Gloves.
Marinite and Marinite Floats for Molten Metal Casting
For most HDC and FDC ingot operations, Johns-Manville's (J.M.) asbestos-free Marinite-C board should replace the asbestos Molten Metal Marinite. The applications for Marinite-C include molten metal transfer troughs, baffles, basins and floating skimmers. In certain applications, an acceptable alternate for Marinite-C is Pyrotek's asbestos-free Pyrotherm B-3 manufactured by Cape Boards of England. Johns-Manville's asbestos-free Marinite-I is not recommended for molten aluminum operations.
(Marinite is continued on Page 3.)
ARD 003557
ARD 003558
Material & Use Pump Packing
1982 February 16
ASBESTOS REPLACEMENT PROGRAM (Page 3)
Replacement Status
An asbestos-free material for the critical HDC and
FDC header applications (sheet ingot headers at Tennessee
South Plant and Warrick, Hunter caster tips at Badin,
small round HDC headers at Badin, and tool and jib plate
headers at Vernon) has yet to be developed for
commercial use. Until this product is available,
we will continue to use asbestos header grade
molten metal Marinite.
.
Almost all asbestos uses in FDC ingot operations can be replaced by Alcoa's R-680.
In most cases, pump packing materials are bonded in rubber or some other coating compound. These usually generate little potential for fiber exposure and need not be substituted. However, some packings, such as uncoated, noncompressed, braised asbestos may offer a potential for exposure and should be replaced. The plant industrial hygienist should be consulted when there is a question of whether or not a material should be replaced.
Since specific needs and equipment types vary dramatically, pump packing and general packing materials are purchased at the plant level. Suitable replacements should be sought by plant Purchasing by direct contact with manufacturers and suppliers.
ARD 003559
Material & Use Rope for packing
and sealing
Tubing Tape for furnace seals and general insulation
ASBESTOS REPLACEMENT PROGRAM
(Page 4)
Replacement Status
Fiberseal A-l Rope (Pyrotek, Inc.) can be used in place of asbestos rope for sealing the gap between the mold and bottom block in FDC casting operations. It prevents metal leakage and its good thermal stability allows it to be reused numerous times. It may also be used for sealing joints in pouring troughs.
Z-5 Treated Fiberglass Rope (Pyrotek, Inc.) can be used successfully as a crucible lid gasket on vacuum-type potroom tapping crucibles. It replaces the presently used Johns-Manville 872 or 702 asbestos gasketing material. However, Z-5 will not replace gaskets made of twisted aluminum foil. Plants using foil gaskets will in all probability have to continue that practice.
Fiberseal K-2 (Pyrotek, Inc.) has been used successfully by Massena as a replacement for the asbestos rope which was used to pack bottom blocks.
Another alternative is Thermo-Ceram Rope by Garlock.
Tape replacements include Pyrotex, Refrasil, Fiberfrax, and Nor-Fab.
1982 February 16
Material & Use Thermocouple Wire
ASBESTOS REPLACEMENT PROGRAM
(Page 5)
Replacement Status
Sleeves made of Refrasil or Fiberfrax material may be used in place of asbestos-coated wire in some cases. Tennessee has successfully used a fiberglasscoated, braided, and wrapped thermocouple wire from Thermoelectric Co., Saddlebrook, N.J. - P/N Q/Q/20-J (Standard Grade) in their ingot preheat and a two conductor 20 gauge premium grade thermocouple wire Q/TW-20-JJ in their annealing furnace.
Warrick has found two thermocouple wire substitutes:
1. J type lead wire 6A16 gauge by Thermoelectric.
2. K type 16 gauge wire made of fused teflon, polyvinyl and fiberglass by Claud S. Gordon Co.
A ceramic fiber product from 3M, Nextel 312, has been tried, but it has not held up during use.
1982 February 16
ARD
8
01
ASBESTOS - POTROOM USE SUBSTITUTES (Page 6)
1982 February 16
Specific Application
Cradle to Pot Shell Insulation
Substitute
Location
Quarry Tile
Wenatchee
Curit Fiberglass Fill Board Warrick
Cerawool Fill Board
Warrick
Cem-Fil GRC Sheet
Warrick
Cem-Fil GRC
Massena
J-M Asbestos-Free Millboard Massena
Comments
Good replacement
Seems OK
Will test
Didn't hold up
Not successful
Installed on some pots and appears OK. Will be used on all future pot rebuilds.
Mechanical Engineering Division, Pittsburgh, specifies Johns-Manville Cerawool Millboard as a substitute for JM-106 Millboard. Compressive strength and insulating quality are comparable. Cost for Cerawool Millboard is $1.50 each for 1/4" x 3" x 48" pieces in lots of 250, or $1.25 each in lots of 500. This is less than the $5.00 per piece you are paying for Chem-Fil board.
ARD 003561
Superstructure Foot Insulation
Cem-Fil GRC 9"x7"xl" Marinite P - 1/2" sheet R-680
Badin
Massena Badin Badin
Product was not even and resulted in rocking of the superstructure.
To be tested
Crushed
Currently testing
Mechanical Engineering Division, Pittsburgh, presently specifies ebony asbestos for this item. Tests on other materials have not been successful.
ASBESTOS - POTROOM USE SUBSTITUTES (Page 7)
1982 February 16
Specific Application Pot Cover Insulation
-
Substitute
Almac Plastic Industries' High-Temp. Glass
Marinite P - 1/2" sheet
Pyrotek Fiberseal H-3 Fabric
Amatex-Thermoglass //G-36P752
Location Massena
Massena Badin Massena Warrick
Wenatchee Badin
Comments
To be tested
Not successful
Double the fabric; works well for repairs.
Not successful
Works well; now standard; also works for sideshield insulation.
Satisfactory
Will use in all new pot covers.
Mechanical Engineering Division, Pittsburgh, has eliminated use of Asbestos by wrapping Amatex-Thermoglass //G-36P752 around an aluminum bar. In other installations, fiberglass fabrics have been used as the insulating material.
ARD 003562
1982 February 16
ASBESTOS - P0TR00M USE SUBSTITUTES (Page 8)
Specific Application
Walkway Grating Insulation
Substitute Pyrotek E-40 Pyrotek Phenolic Paper Pyrotherm G-5 Insulating Board Marinite P - 1" Board Marinite P - 1/2" Board
GRC Cem-Fil 1/4" & 3/8" M-50 Pyrotherm Dense Board Chem-Fil Fiberboard by Louisville Insulation
Location Bad in Bad in Bad in
Bad in Bad in Massena Massena Massena Warrick
Comments
Crumbled
Currently testing; easy to work with but expensive
To be tested
Not satisfactory
Not satisfactory
Not successful
Not successful
Unsuccessful; it crumbles.
Currently trying this cement-fiberglass product
Mechanical Engineering Division, Pittsburgh, specified Chem-Fil fiber reinforced cement for the new Badin and Noranda potlines. Previously specified Koppers NCX (fire-retardant) treated wood. The disadvantage of wood is that it still chars when exposed to molten bath. The cost of Chem-Fil and treated wood are comparable.
ARD 003563
ASBESTOS - P0TR00M USE SUBSTITUTES (Page 9)
1982 February 16
Specific Application Bus Insulation
Substitute Marinite P - 1" sheet Marinite P - 1/2" sheet Cem-Fil GRC 1/4" & 1/2"
Location Bad in Massena Massena
Pot Exhaust Duct
Pyrotek Pipe Hetron 197
(
Warrick
Bad in Wenatchee
Hetron 92
Wenatchee
Fiberfrax Laminate Tubes by Carborundum, Inc.
ATC
Comments
Crumbles
Not successful
Not successful
Mechanical Engineering Division, Pittsburgh, eliminated use of transite by substituting an aluminum bar with a 1/16" layer of glass fabric epoxy, NEMA Grade G-ll, taped to each side of the bar.
Looked good in preliminary testing; continuing testing with interior coatings to prevent corrosion.
Looks good on 9 pots; changing to this product.
Fiberglass pipe with antimony and dynel liners failed, and replaced by normal transite.
Fiberglass pipe with antimony and asbestos linings satisfactory.
Currently testing
Mechanical Engineering Division, Pittsburgh, has conducted extensive tests on Hetron 197 at Wenatchee and Warrick. This material is quite expensive and may not be as durable as transite.
ARD 003564
ASBESTOS - P0TR00M USE SUBSTITUTES (Page 10)
1982 February 16
Specific Application Exhaust Duct Gaskets
Substitute
Pyrotek Fiberseal Felt T-l
Pyrotek T-22 Fiberglass Cloth
Location Massena
Massena
Siphon Gaskets
Pyrotek Fiberseal M-13 1/8" Compressible Board
Fiberseal Felt G- 1 1/2" & T-l - 1/4"
J-M Asbestos-Free Millboard J-M Ceraform Heat Seal
Massena Badin Massena Badin Massena Rockdale
Comments Not successful
Successful; replacing asbestos as pots are rebuilt.
Mechanical Engineering Division, Pittsburgh, is specifying asbestos impregnated sheet material; however, Garlock's Gylon material would probably work for this application.
Satisfactory
Currently using this product.
Unsuccessful
.
Tested and proved OK, but prefer Fiberseal M-13.
Satisfactory, presently in use.
Not as stable as asbestos; needs to be replaced more often.
Mechanical Engineering Division, Pittsburgh, presently specifying Pyrotek T-l felt material for this application.
ARD 003565
ASBESTOS - POTROOM USE SUBSTITUTES (Page 11)
1982 February 16
Specific Application Ladle & Ladle Lid Seal
Substitute
Silicon Red Rubber Air Hose - 3/4"
Location Warrick
Fiberseal Rope F-10, 1-1/2" Massena
Refrasil-wrapped around rubber hose
Bad in
1" Fiberseal Rope D-l
Anaconda
Pyrotek Treated Z-5 Tape
Massena
High Temperature Exposure Insulated Electrical Wire P-75, P-225 Potwiring, P-225 Jackmotors, Calrod heaters
High Temperature Silicon Braid Copper Conductor, 1000 V., 200C
Massena
Comments Standard usage (but different seal than other plants) Unsuccessful No good; rubber melts; seal breaks
Uses 600 ft. per month of D-l Successful; presently in use. Mechanical Engineering Division, Pittsburgh, presently specifying Pyrotek Z-5 material. Several layers of this material are used for one seal.
Satisfactory. Limited replacement practice.
ARD 003566
ASBESTOS - CARBON BAKE USE SUBSTITUTES (Page 12)
1982 February 16
Specific Application
Exhaust Duct Manifold Gaskets
Substitute
Pyrotek Composition Boot V-5, M-6, H-3 Fabric
Location Massena
Comments To be tested. Expect shipment October 1981.
ASBESTOS - WIRE, ROD AND BAR USE SUBSTITUTES
Specific Application Jarke Rack Liners
Substitute Pyrotek 747 Cloth Pyrotek F-l Cloth Pyrotek T-23 Tape Pyrotek Glass and Kevlar
Blend Pyrotek T-22 Tape Newtex Fabric Tape Zetex 1200 Tape Zetex 32500
Location Massena Massena Massena Massena
Massena Massena Massena Massena
Comments Unsatisfactory; frays easily. Unsatisfactory; frays easily. Unsatisfactory; frays easily. Unsatisfactory; frays easily.
Unsatisfactory; frays easily. Unsatisfactory; frays easily. Unsatisfactory; frays easily. Successful so far; encouraging.
ARD 003567
Product Pyrotex
Fiberseal Products
Refrasil Nor-Fab Yarns;
Fabrics Fiberfrax
Hi-Temp 270 Ceramic Fiber
Products
Marinite and Other Products
ASBESTOS REPLACEMENT MANUFACTURERS (Page 13)
Supplier
Newtex Industries, Inc. Railroad Avenue P. 0. Box 25 Victor, New York 14564
.
Pyrotek, Inc.
East 9601 Montgomery Avenue
Spokane, WA 99206
-0R-
Box 77 - R.D. #1
Claremont Road
'
Carlisle, PA 17013
-0R-
Santa Fe Springs, CA
HITCO Division of Armco Steel Middletown, Ohio 45042
Amatex 1032 Stanbridge Street Norristown, PA 19404
The Carborundum Company Insulation Division P. 0. Box 808 Niagara Falls, NY 14302
Penn Compression Moulding, Inc. Burton Street Pittsburgh, PA 15218
Kaowool Babcock & Wilcox
Cem-Fil Corporation Two International Plaza Drive Nashville, TN 37217
Keller Glove Mfg. Co. Plumsteadville, PA 18949
Johns-Manville The Manville Corporation Ken-Caryl Ranch Denver, CO 80217
1982 February 16
Telephone No. 716/924-9135 509/926-6211 717/249-2075
215/277-6100 716/278-6221 412/351-4004
615/361-4664 215/766-8818 303/978-2000
ARD 003568