Document xJBb5OqwXaBrna3EV19JyaZm
fan.......
^ ...
/- " LIA23027
HMjjiBlHMSiTlltiff'^1 ariffttr"Irrrria jfjn-rriiiti'rriaaM-Tn'r'iiniiif
LEAD INDUSTRIES ASSOCIATION
4atftMPOBO>OKf>Tirot 60 East Und Street n ew toa* it. H-t.
September 19, 1956
SUBJECT i LEAD BCHDIH0 CONSTHUCTIOI
mcani H57T-------------
Lead Shower and Safa Pans
To Kembere of the Laad Industries Association! Enclosed please find a copy of the second of our aeries of teed
Building Construction Bulletins for distribution to the building industry. This follows the release in Kay of this year of Bulletin Ho. 1 on teed Taste Connections for flushing fixtures with integral Trepe.
This Wletin is being distributed to approximately 20,000 archi tects and others lc the building industry and 10,000 plumbing contractors.
Extra copies are erailaba to members in Quantities up to 25 at 1h no charge. Larger Quantities are available at our cost of 6U.00 per hundred-
Ssiinnec*erely yours,
5*cr*t*3r7 * ^fi
wtei imti i>
S"
wpv
>^7ji'jii|iyiwiiT iwmi'mmrrwmB&xsfim
30^
r*
-J*r**^
0
N 1990.01
wwwwwri
'%
m yw* u A23029
,W
Hi
^'W-S
_i
,
.
sr:.*-
UV.
' & ir*r *:i*'
rs- ~;s '
i v\
XL^rru ini. increased imptrtanrr of stall showcn
in todat'i building plant, ample provision thouM be made to provide (of complete waterproofing of such ftxtutn. Onr of t!r riiirtt, wmt, and no*t widely used water-proofing mrthodt it lie uv of lead shower pans. The tpreifiration on the following page pro* vidrd therefore to assist those wrho who to take ad* vantage of lead's outstanding waterproofing qualities.
Sheet lead ran also be used to advantage in the waterproofing nf areas other than shower stalk or moms. Lrad safe pans under soda fountains, krtchem, and other places where leakage or spillage may occur, will preside the same high degree of waterproofing that is expected of lead shower pans. In general, the rame method of installation as outlined in the specs* firatson for lead shower pans should be followed.
IMPERVIOUS TO MOISTUKE Lead shower and
safe pam properly installed provide an impermeable moisture hjrnrf between the unit itself and the ad joining walk and floors* a barrier that is necessary if damage to beams, joius, studs or decorated surfaces is to be avoided Lead pam cannot absorb moisture. Such is not the case with noo-metallic pam.
DURABLE Sheet lrad is rxtrmw-ly durable for surh
applications. Its use as a standard material in chem ical plants handling man)' types of romwm attests to this fart.
WORKABLE Short lead *f extremely workable and
can easily he made to conform to the surfaces on whirh the sheet load pan is applied Thus, voids hetwrrn tlx* lead pan and flooring, inhrrrnt in more rigid materials, are not left to settle out after the tile floor is installed. causing the tUr to crack and buckle.
ADAPTABLE Sheet lrad is extremely adaptable for
use in all sirr or shape shower stalls or rooms. Sheet lead pans are cavils and qwi< lh installed for minimuni sire dtower stalls, or in lar^e rooms 01 areas.
CQST The < r.st of sheet lead showrf and safe pam
is vurjriinrh km. The Haric material cost has Irvrlrd off to f pent where lead is directly eoniprtitive with other quality materials. The rase of working lead rrduret cents.
FRECAUTIOK frren irmrnt. com me or mortar
containing for time may hr corrosive to lead as it is to mans <*th-f crnmixm inetak. It is therrforr nenv vary to <<ui the lead v.ith asphaltum to protect it dunnv the curing stage of fhr cement. After the cur ing. the asphaltum i oating whit h jmnidrd the nrersvan interim jrotcvtkn is rm Wigrr important.
TECHNICAL ASSISTANCE iv <r.hm.*] u.ff d
the Avvimiaiion h at yrwir disposal in helping you mlvr )oir lead pn4ilritis. Other "Bulletins*' in this series ith lude "lrad (IfNNnMlion Bulletin No. 1 - S|m ilu jti>Ni fr l.*ad Waste Conor* tkm for Plumb ing Fixtures uith Integral Traps** asaitahlr upon re quest Aildfew v ik j i request for literature and other inquiries to: Atihttotural Drpt. Lead Industries As** utn*n. Fast f2nd Strrrt. New York 17, N. Y.
m
(
i i i. m laiw^Ki
iiuwjiijiiyi uifuppn m**m IIJJIL I Jlii iippppiifji %
TM -Vaaa^
\
SpedficoHoa for O LEAD SHOWER AND SAFE PANS
Short load for shower (safe) pan* shall he hi accordance with Federal Specifications QQ-L-201a, June 4, 1953, Lead; Short, Grade B or better.
Shower stall (room) Boon (
..........
)
shall be completely lined with 4 lb. (6 th^ 8 lb.)
sheet lead pans turned at lea* 6 in. up the tide
walb all around or at least 1 in. above the finished
Boor. Comers of pans shall be folded tightly against
the upland (and soldered (wrldftfl] along the
t<p). (Comen of pans shall be a lap joint pre
pared by lapping one side of the upland ovTf
the ether at least 1 j in. and soldering f PridingJ
the vertical seam).
^
Top of uplands shall be set back % in. into notcho in studs. Top of uplands shall be dr-need tightly against masonry walk). In room* too Urge to be covered by a single sheet of lead, team* joining sheets shall trapped at least */* m. io direction of (low and 'wtldedj soldered, wrhb solder sweated brtwern the sheets to the width of the overlap. Pipe or structural members protruding through the lead pan shall br flashed with lead boots or sleeves extending to a height equal to the upsland and tic Modern) w*ddrd) to the pan. (aKKtrtc under pan* sliall be brought to a smooth finish With a mixture of crmoit and sand, and the lead wrll touted on both side* with a good grade of asphaltum. Wood floors under pans shall be firm and evrn with nail heads art. and made of well-seasoned j* in. hoard* covered with asphalt* impregnated (>uilding paper weighing at lea* 15 Ih. per square. I aside of pans on wood Boon shall be well coated with a good grade of apHaltum.) Building paper shall he laid over the inside of lead pans on top of the asphahum coat ing if the pan* are left uncovered and there 0 danger of mechanical injury. A cement and sand mixture shall be used inside pans as foundation for tile. Pan* shill be graded to the flour drain to which they shall be serurelv soldered welded)
clamped >. The trap flange shall he countersunk and weep holes provided in the drain just afxne (he lead fun. lhe trap shall lie plugged and pan filled with water as a test brfore installing the irmcnt and tile.
*|f aW iSm *1Mrfcf MIJ wt rrnmm. frnf) krff njrl Tft ! Im> In m4
LIA23030
LIA23031
Iniidiifil a itott Mad p m Mdtf a aada lamiUa Kota Hh *ii laadMI la tarn It pan* (laaili Ip attract
o PRACTICAL SUGGESTIONS
IV drijititl duwiiio in thn MBilhin" art* iirludfd j iMr |t3< tiiil MH'crvitHt* and rnmmnmdrd mrth*h *f iih.jllinc Irjd dKmrr and uf<- pan* fnr \ arum* i\|m fd imulUliitn. |luMinc A. B and (! >n thr |ndimj (mc i- Um** \jii<n; nwilH<V uvxl in immntinc a Irad V*Tf nr sj|> |mii llir |>luiiUi< (tuirui1! ikM'in. The nrfind 4nwn m DuMmc "A** V jmduhly thr n**f v.iti*l.t; l**r\ in dial all pHnl% air 4drrd and thu* Jr^* Mil.pii i. ]>al.ac< AU< 'VjirriMvr fitting' *ith Mia.luniaal iiw tl**d id }<iiiitinc arr i*m mjuirrd
o
yqgjg