Document xB9xJ89Br6rqvpNqzzrnw03g

UNITED STATES ENVIRONMENTAL PROTECTION AGENCY REGION 4 ATLANTA FEDERAL CENTER 61 FORSYTH STREET ATLANTA, GEORGIA 30303-8960 ELECTRONIC MAIL CONFIRMATION OF EMAIL RECEIPT REQUESTED Honorable Darlene O. Spivey Mayor, Town of Trenton P.O. Box 399 Trenton, North Carolina 28585 darlene@darlenespivey.com Re: Reconnaissance Inspection Report Town of Trenton Wastewater Treatment Plant National Pollutant Discharge Elimination System Permit No.: NC0021342 Dear Mayor Spivey: The U.S. Environmental Protection Agency, Region 4 and the North Carolina Department of Environmental Quality (NCDEQ) inspected the Town of Trenton, NC Wastewater Treatment Facility located at 609 Jones Street, Trenton, North Carolina 28585 on October 20, 2021, for compliance with its National Pollutant Discharge Elimination System (NPDES) permit and the Clean Water Act (CWA). Enclosed is a summary of the inspection. The inspections findings and recommendations are provided in the enclosed Reconnaissance Inspection Report. If you have any questions about the inspection report, please contact Richard Elliott at 404-5628691 or via email at Elliott.Richard@epa.gov. Sincerely, JAIRO CASTILLO Digitally signed by JAIRO CASTILLO Date: 2021.12.08 11:12:08 -05'00' Jairo Castillo, P.E., Chief Wastewater Enforcement Section Water Enforcement Branch Enclosure cc: Tony Hawkins Wastewater Treatment Plant Manager John Hennessy NCDEQ Bob Sledge NCDEQ Internet Address (URL) http://www.epa.gov United States Environmental Protection Agency Region 4 CV-NC-0021342-10-20-2021 Reconnaissance Inspection Report SECTION A: National Data System Coding NPDES No. MO/DAY/YR Inspection-Type Inspector NC0021342 10/20/2021 ROS (Reconnaissance Richard Elliott/Tristan without Sampling) Odekirk SECTION B: Facility Data Name and Location of Facility Inspected (For industrial users discharging to POTW, Entry Date/Time also include POTW name and NPDES permit number) Town of Trenton WWTP 609 Jones Street, Trenton, North Carolina 28585 10/20/2021 10:00 AM Exit Date/Time 10/20/2021 12:00 PM Names of On-site Representative(s)/Title(s)/Phone and Fax Number(s) Other Facility Data Tony Hawkins, Plant Manager, 252-521-7687 N/A Robbie Bullock NCDEQ, 252-948-3843 Facility-Type Publicly owned treatment works Permit Effective Date 12/1/2017 Permit Expiration Date 5/31/2022 Name, Address of Responsible Official/Title/Phone and Fax Number Honorable Darlene O. Spivey Mayor, Town of Trenton P.O. Box 399 Trenton, North Carolina 28585 252-448-1784 Contacted Yes No Permit SECTION C: Areas Evaluated During Inspection (Check only those areas evaluated) Flow Measurement Operation & CSO/SSO (Sewer Maintenance Overflow) Records/Reports Self-Monitoring Program Sludge Handling/Disposal Pollution Prevention Facility Site Review Compliance Schedules Pretreatment Multimedia Effluent/Receiving Waters Laboratory Storm Water Other: SECTION D: Summary of Findings/Comments (Attach additional sheets of narrative and checklists as necessary) See the attached narrative of Findings/Comments. Name(s) and Signature(s) of Inspector(s) Elliott, Richard Digitally signed by Elliott, Richard Date: 2021.12.08 11:19:35 -05'00' Richard Elliott, P.E. Signature of Management QA Reviewer JAIRO CASTILLO Digitally signed by JAIRO CASTILLO Date: 2021.12.08 11:13:02 -05'00' Jairo Castillo, P.E. Agency/Division/Phone and Fax Number EPA/ECAD/(404) 562-8691 Agency/Division/Phone and Fax Number EPA/ECAD/(404) 562-9257 Date 12/8/2021 Date 12/8/2021 Page 1 of 3 United States Environmental Protection Agency Region 4 CV-NC0021342-10-20-2021 Reconnaissance Inspection Report (Continued) Section D: Summary of Findings / Comments On October 20, 2021, the U.S. Environmental Protection Agency, Region 4 and the North Carolina Department of Environmental Quality (NCDEQ) conducted a Reconnaissance Inspection (RI) of the Town of Trenton's wastewater treatment plant (WWTP) located in Trenton, NC. EPA and NCDEQ met with Mr. Tony Hawkins and reviewed the facility's monitoring records and discussed the facility's self-monitoring program. The following is a summary of the RI findings and observations. I. Records/Reports The inspection observations verified the permit information regarding the name, description of the facility, location of the permitted outfall, and the location of the receiving waters. A copy of the permit was kept at the facility. Violations noted in the EPA's database occurred during the startup phase of the new WWTP (for Phosphorus limitations) and during a period of extreme rainfall (flow violation in the first quarter 2021). The old WWTP has been decommissioned and all wastewater from the town is now treated at the new WWTP. The new WWTP was commissioned in September 2019. The EPA database is showing several months of missing DMRs. However, the NCDEQ database does not has these violations reflect in its database. Further, the Town operator asserts that he has not been late on any of his required submission. NCDEQ staff Robbie Bullock is following up with NCDEQ headquarters in Raleigh, NC to investigate the data discrepancy. II. Facility Site Review The Town of Trenton, NC recently constructed a new WWTP. The activated sludge package plant is permitted to treat 0.14 million gallons per day (MGD) of wastewater per day. Ultraviolet (UV) disinfection is used for pathogen control. The WWTP is located in an area that has additional lands that can be used to expand the treatment plant if regionalization with other towns is accomplished. III. Flow Measurement The facility is permitted to treat 0.14 MGD and on average treats 30,000 gallons per day. Flow is measured using an inline Mag meter device. The flow measurement device was last verified on 8/26/2021. IV. Self-Monitoring Program Sampling and analytic testing are conducted by Environmental 1 and Vanns laboratory. In-situ sampling is conducted by the on-site operators. Page 2 of 3 V. Operation & Maintenance The facility is operated by one operator/plant manager. The wastewater collection and transmission system (WCTS) is operated by the WWTP operator. Recent improvements in the WCTS have removed a significant amount of I/I from the influent to the WWTP and has assisted with consistently achieving effluent limits. VI. Sludge Handling The solids from the treatment process are lime stabilized in an aerated digester before being hauled to a land application site. VII. Effluent/Receiving waters Receiving water could not be observed. The WWTP discharges to the Trent River. No foam or screen was noticed on the effluent leaving the treatment plant. End of Report Page 3 of 3