Pydraul MC
A High-Performance Hydraulic Fluid For Safer
Hydraulic Operation With Minimum Maintenance
PydraulMC fire-resistant hydraulic fluid was developed spe
cifically for use in mining equipment. It is a' phosphate-ester
based formulation containing no water. It meets the fire resis
tance requirements of the U.S. Bureau of Mines Schedule #30.
Equally important, field experience since 1972 shows that Pydraul
4 I U *1
MC^offers the following operating advantages:
.
' * Reduced Fluid Maintenance
Unlike water-based hydraulic fluids that are oil
emulsion or glycol solutions -- Pydraul MC does
not lose water by evaporation to change composition
and viscosity.
.
* Eliminates Hazards From Spillage
Water-based fluids that evaporate off their water
component can leave behind flammable residues in
reservoirs, spill pools or crevices.
* Operates At Higher Temperatures 5 Pressures
Pydraul MC has excellent viscosity characteristics
and a high degree of lubricity that permits efficient
hydraulic operation at pressures up to 5,000 psi.
* Gives Equipment Protection From Corrosion 41 u IJ
Pydraul MC^does not create a rust:-promoting environ
. ment in operating equipment. It is chemically stable
to help eliminate corrosion problems.
2.
^Rq;s4ercl
of MonH^
0V08i33
TOWOLDMONOQ22687
Monsanto's development of fire protection for industrial
hydraulic operations began with the first Pydraul fluid in 1951.
Pydraul fluids have since provided industry with millions of ma
chine hours of safe operation.
Pydraul MC was designed to enable ore and coal mine operators
meet the current safety legislation that requires a fire-resistant
fluid in unattended equipment and either a fire-resistant fluid
or suitable fire suppression devices in attended equipment. The
initial cost and maintenance of fire suppression devices may show
that a stable fluid such as Pydraul MC would be the most economical
choice in the long run.
.
Pydraul MC is a dependable hydraulic fluid for safer operation
of above- and below ground equipment with minimized maintenance.
It may be used in the hydraulic systems of the following:
Power Shovels 5 Draglines Blasthole Drills Bulldozers $ Rippers Tractors Scrapers 5 Graders Crushers Ore Feeders Trucks Jumbos Ore Drills Mechanical Loaders 5 Scrapers
-
0v6V
TOWOLDMONOQ22688
4.
The following pages give data that illustrate the typical
properties and performance of Pydraul MC as measured by standard
test procedures used to describe hydraulic operation and fire
resistance:
-
*
0V
TOWOLDMONOQ22689
Pydraul MC Typical Physical Properties *
Appearance
Specific Gravity 25/25C.
Density at
140F.
77F.
Neutralization No. (mg KOH/g) max.
Moisture (max.) %
Viscosity
'
Centistokes 8 40F.
100F.
210F.
SSU 8 40F. 8 100F. 8 210F.
Pour Point Coefficient of Thermal Expansion per F. Specific Heat BTU/lb./'F. 8 77F. Thermal Conductivity BTU/hr./ft./F. Solubility in Water
Clear Green Liquid 1.098
1.07S grams/ml. 1.100 grams/ml. 0.30 0.15
1250 cs 69 cs
6.9 cs
5800 SSU 320 SSU 48 SSU
-10F. 0.00034 0.39 0.0728 Negligible
*Data based upon typical quality control samples tested in our \ ^
laboratories. Complete sales specifications are furnished J
on request.
Jr
0108136
'
TOWOLDMONOQ22690
)
'gsgug g gmg
a8s*!
I
8*
8--8
'8
882 * 2
5
f fI
TEMPERATURE, DEGREES FAHRENHEIT
J
0108137
TOWOLDMONOQ22691
Pydrau/W Typical Performance Properties
7.
Foam Test (ASTM D892) Sequence 1, 2, 3
Pass
Rust Test ASTM D-66S (Sequence A)
- Pass
Hydrolytic Stability Test (MIL-H-19457)
Pass
Oxidation and Corrosion Test (FS791-3508) (168 hr., 250F., S 1 air per hr.)
y Metal Weight Changes, mg/cm
Magnesium A1uminum Cadmium Steel Copper
'
-0.01 + 0.05 -0.01 + 0.01 -0.02
Acidity Increase, NN
2.58
100F. Viscosity Increase, %
13.1
Compatibility With Materials
Metals
Pydraul MC is compatible with ell the commonly used metals of construction.
Paints Other Fluids
Cured epoxy, phenolic, polyurethane and nylon based paints are satisfactory. INTERIOR SURFACES ARE PREFERABLY LEFT '
UNPAINIED. Pydraul MC is miscible in all proportions
with the Pydraul E and Pydraul C Scries of fluids. It is essentially insoluble in water.
Packings, Seals, Hoses and Bladders
Materials compatible with Pydraul MC are
necessary for dynamic or moving seals.
For static seals they are preferred but
not essential. .
Suqciested
Re coifintemied
Marginal*1
Unsatisfactory
VTton
BUTYL
BUNA-N
NYLON
EPR
NEOPRENE
TEFLON
NATURAL RUBBER
FLUOREL
SILICONE
'`Although generally classified as marginal with Pydraul fluids, butyl and EPR (ethylene propylene rubber) have proven satisfactory in equipment operating
under certain conditions of temperature, fluid cleanliness, maintenance, etc. For best service under general all-around operating conditions, elastomers of Viton, Nylon, Fluorel, Teflon, and silicone are suggested.
0108139
TOWOLDMONOQ22693
Pydraul" MC FiregResistance Properties
Flash Point
Fire Point
Autognenous Ignition Temperature (ASTM D2155)
Factory Mutual High Pressure Spray Test
CTest fluid sprayed @ 1000 psi through orifice, passing through flame of propane torch.)
Factory Mutual Hot Channel Test
(Test fluid sprayed 8 1000 psi through orifice, onto hot channel iron 8 1300F.)
U.S. Bureau of Mines Approval Schedule 30
4 75 0 F 52SF 800F Pass Extinguished in less than S sec. after torch removed. Pass
Yes, Number 30-6
Fire Resistance Advantages of Pydraul Pydraul fluids protect hydraulic equipment and personnel with
permanent fire protection. Pydraul fluids contain no water to evaporate and leave a flammable residue. During their many mil lions of machine hours of use, Pydraul fluids have been acciden tally sprayed over molten metal, through electrical arcs, into flames and sparks without disaster. They pass all of the important ignition tests for fire resistance.
"NOTE: Materials designated 'fire resistant' generally are more difficult to ignite, or once ignited, bum at a slower rate than corresponding conventional materials. This term does not mean that fire resistant materials will not bum. However, when properly used. Monsanto's fire resistant PYDRAUL0 HYDRAULIC FLUIDS are useful in helping customers meet their fire safety requirements."
0l08l`,
TOWOLDMONOQ22694
9.
CONVERTING MINING EQUIPMENT HYDRAULIC SYSTEMS TO PYDRAUL MC
Regardless of the type of hydraulic fluid being used, con verting a system to Pydraul MC is easy. Virtually every type of equipment that uses fire-resistant hydraulic fluid has been con verted to Pydraul phosphate-ester fluids. Most equipment manufac turers are experienced in Pydraul fluid conversions and should be consulted.
If changing seals is necessary, equipment manufacturers can recommend which to change, and many carry a supply of compatible seals. Laboratory tests and operational experience show Viton*, Teflon*, and silicone to be the preferred elastomers.
To replace other fluids which are compatible with Pydraul and where compatible seals are already in the system, it is only necessary to add Pydraul MC as make-up fluid. It is not necessary to drain or clean. However, when converting from petroleum oils, non-compatible synthetic fluids, water-glycol fluids, or waterin-oil emulsions -- the following steps are recommended. These conform to USA Standard B93.5 -- 1973.
Changing from Petroleum Oil 1. Completely drain and clean the system. Small amounts of oil will not interfere with the performance of Pydraul, but resistance to fire is reduced by the amount of oil left in the system. 2. Drain and blow out pipelines. Manually clean valves and reservoirs.
`Registered trademark of E.I. Du Pont de Nemours 5 Co., Inc. 010814*
TOWOLDMONOQ22695
10.
3. Open or remove-and-drain all valves. Replace gaskets; packings, and seals with compatible materials. It is particularly important to change dynamic seals. Static seals do not necessarily have to.be changed if they are tot leaking. Non-compatible static seals can be replaced
. when the component is disassembled for maintenance.
4. Remove pumps, accumulators, and cylinders, if neces sary, for draining. Replace packings, seals, gaskets, and bladders with materials compatible with Pydraul.
5. Check component functions before the system is closed and fluid is. added.
6. If the system cannot be completely drained, it may have to be flushed out with a small amount of Pydraul.
Changing from Water-Gfycol or Water-in-Oil Emulsion
1. Drain and clean system thoroughly. Remove all traces
of water. Empty all lines and low points or dead
pockets in components.
'
2. Clean with steam or warm water. Follow by blowing with dry air.
3. Check sealing materials, hoses, and accumulator bags. Replace if necessary with compatible materials.
4. Install a minimum charge of Pydraul and operate the system from 16 to 24 hours. During this period, in spect the reservoir. If water or other contaminants float to the top, remove by skimming.
01081*2
TOWOLDMONOQ22696
11.
5. Drain the flushing charge immediately after shut-down
while the fluid is warm. Drain all isolated points
or parts which do not drain back to the reservoir.
If water is apparent in fluid clinging to walls, wipe
down all accessible parts.
,
Ask the Monsanto fluids specialist for suggestions and assistance. He may be reached by phoning the nearest sales office listed on the back cover.
*
OV"ftV
TOWOLDMONOQ22697
12.
Pydraul MC Toxicity and Safe Handling Animal studies indicate that Pydraul MC can be classed as practically non-toxic when considered as an industrial fluid. It is non-irritating when the skin is exposed to the fluid. In case of skin contact wash off with soap and water as a hygenic procedure. In the case of eye contact flush with copious amounts of water. Due to its low order of toxicity, Pydraul MC requires no special handling precautions.
*
018V
TOWOLDMONOQ22698
r
CUSTOMER SERVICE CENTERS
AKRON, OHIO 44313
260 Springtide Drive Montroso Development Park 7d. (216) 666-4111
ATLANTA. GEORGIA 30339
320 Interstate North Parkway Suite 500 Tel. (404) 432-7711
BOSTON. MASSACHUSETTS 02149
Everett Station Tel. (617) 387-5010
CHICAGO. ILLINOIS
3158 Dcs Plaines Ave. Dcs Plaines. Illinois 60018 Tel. (312) 296-6688
CINCINNATI. OHIO 45236
8041 Hosbrook Road Tel. (513) 984-1100
DETROIT. MICHIGAN
500 Northland Towers West Southfield. Michigan 48075 Tel (313) 357-0910
HOUSTON. TEXAS 77027
1301 Post Oak Tower 5051 Westheimer Pood Tel. (713) 621-9550
LOS ANGELES. CALIFORNIA
1401 Dove Street Newport Reach, California 92660 Tel. (714) 833-9150
NEW YORK, NEW YORK 1D036
1114 Avenue of the Americas Tel. (212) 764-5000
ST. LOUIS. MISSOURI 63166
800 N. Lindbergh Dlvd.
Tel. (314) 694-1000
,
SAN FRANCISCO BAY AREA 2710 Lafayette Santa Clara. California 95052 Tel. (408) 243-0414
SEATTLE. WASHINGTON 98121 2112 Third Avenue Tel. (206) 622-4203
WILMINGTON. DELAWARE 19810
Suite 204. Bancroft Bldg. 3411 Silvcrside Pood Tel. (302) 478-4600
Monsanto Industrial Chemicals Co. A Unit of Monsanto Company 800 N. Lindbergh Blvd.. St. Louis. Mo. 63166
01081**^
NOTICE: "Nothing contained herein is to be construed as a recommendation to use any product in conflict with any patent^
MONSANTO MAKIS NO WARRANTIES AS TO THE! HTNLSS fOR A PARTICULAR PURPOSE. CR Ml.ROHAN l ABU t1Y 01 ANY >
PRODUCT Rl l E fOH O TO, no guarantee ot satisfactory results Irorn reliance upon contained mlormnhon or recommendations'
nd disclaims all liability for any resulting loss or damage."
\^ tV T
TOWOLDMONOQ22699