Document x5wpandGMZ3nbym7OZKzm7YaJ

( PYDRAUi; MC Fire Resistant^W$WiB Hydraulic Fluid ... For Mining Equipment ovov31 8uiU+'* TOWOLDMONOQ22685 010813Z TOWOLDMONOQ22686 Pydraul MC A High-Performance Hydraulic Fluid For Safer Hydraulic Operation With Minimum Maintenance PydraulMC fire-resistant hydraulic fluid was developed spe cifically for use in mining equipment. It is a' phosphate-ester based formulation containing no water. It meets the fire resis tance requirements of the U.S. Bureau of Mines Schedule #30. Equally important, field experience since 1972 shows that Pydraul 4 I U *1 MC^offers the following operating advantages: . ' * Reduced Fluid Maintenance Unlike water-based hydraulic fluids that are oil emulsion or glycol solutions -- Pydraul MC does not lose water by evaporation to change composition and viscosity. . * Eliminates Hazards From Spillage Water-based fluids that evaporate off their water component can leave behind flammable residues in reservoirs, spill pools or crevices. * Operates At Higher Temperatures 5 Pressures Pydraul MC has excellent viscosity characteristics and a high degree of lubricity that permits efficient hydraulic operation at pressures up to 5,000 psi. * Gives Equipment Protection From Corrosion 41 u IJ Pydraul MC^does not create a rust:-promoting environ . ment in operating equipment. It is chemically stable to help eliminate corrosion problems. 2. ^Rq;s4ercl of MonH^ 0V08i33 TOWOLDMONOQ22687 Monsanto's development of fire protection for industrial hydraulic operations began with the first Pydraul fluid in 1951. Pydraul fluids have since provided industry with millions of ma chine hours of safe operation. Pydraul MC was designed to enable ore and coal mine operators meet the current safety legislation that requires a fire-resistant fluid in unattended equipment and either a fire-resistant fluid or suitable fire suppression devices in attended equipment. The initial cost and maintenance of fire suppression devices may show that a stable fluid such as Pydraul MC would be the most economical choice in the long run. . Pydraul MC is a dependable hydraulic fluid for safer operation of above- and below ground equipment with minimized maintenance. It may be used in the hydraulic systems of the following: Power Shovels 5 Draglines Blasthole Drills Bulldozers $ Rippers Tractors Scrapers 5 Graders Crushers Ore Feeders Trucks Jumbos Ore Drills Mechanical Loaders 5 Scrapers - 0v6V TOWOLDMONOQ22688 4. The following pages give data that illustrate the typical properties and performance of Pydraul MC as measured by standard test procedures used to describe hydraulic operation and fire resistance: - * 0V TOWOLDMONOQ22689 Pydraul MC Typical Physical Properties * Appearance Specific Gravity 25/25C. Density at 140F. 77F. Neutralization No. (mg KOH/g) max. Moisture (max.) % Viscosity ' Centistokes 8 40F. 100F. 210F. SSU 8 40F. 8 100F. 8 210F. Pour Point Coefficient of Thermal Expansion per F. Specific Heat BTU/lb./'F. 8 77F. Thermal Conductivity BTU/hr./ft./F. Solubility in Water Clear Green Liquid 1.098 1.07S grams/ml. 1.100 grams/ml. 0.30 0.15 1250 cs 69 cs 6.9 cs 5800 SSU 320 SSU 48 SSU -10F. 0.00034 0.39 0.0728 Negligible *Data based upon typical quality control samples tested in our \ ^ laboratories. Complete sales specifications are furnished J on request. Jr 0108136 ' TOWOLDMONOQ22690 ) 'gsgug g gmg a8s*! I 8* 8--8 '8 882 * 2 5 f fI TEMPERATURE, DEGREES FAHRENHEIT J 0108137 TOWOLDMONOQ22691 Pydrau/W Typical Performance Properties 7. Foam Test (ASTM D892) Sequence 1, 2, 3 Pass Rust Test ASTM D-66S (Sequence A) - Pass Hydrolytic Stability Test (MIL-H-19457) Pass Oxidation and Corrosion Test (FS791-3508) (168 hr., 250F., S 1 air per hr.) y Metal Weight Changes, mg/cm Magnesium A1uminum Cadmium Steel Copper ' -0.01 + 0.05 -0.01 + 0.01 -0.02 Acidity Increase, NN 2.58 100F. Viscosity Increase, % 13.1 Compatibility With Materials Metals Pydraul MC is compatible with ell the commonly used metals of construction. Paints Other Fluids Cured epoxy, phenolic, polyurethane and nylon based paints are satisfactory. INTERIOR SURFACES ARE PREFERABLY LEFT ' UNPAINIED. Pydraul MC is miscible in all proportions with the Pydraul E and Pydraul C Scries of fluids. It is essentially insoluble in water. Packings, Seals, Hoses and Bladders Materials compatible with Pydraul MC are necessary for dynamic or moving seals. For static seals they are preferred but not essential. . Suqciested Re coifintemied Marginal*1 Unsatisfactory VTton BUTYL BUNA-N NYLON EPR NEOPRENE TEFLON NATURAL RUBBER FLUOREL SILICONE '`Although generally classified as marginal with Pydraul fluids, butyl and EPR (ethylene propylene rubber) have proven satisfactory in equipment operating under certain conditions of temperature, fluid cleanliness, maintenance, etc. For best service under general all-around operating conditions, elastomers of Viton, Nylon, Fluorel, Teflon, and silicone are suggested. 0108139 TOWOLDMONOQ22693 Pydraul" MC FiregResistance Properties Flash Point Fire Point Autognenous Ignition Temperature (ASTM D2155) Factory Mutual High Pressure Spray Test CTest fluid sprayed @ 1000 psi through orifice, passing through flame of propane torch.) Factory Mutual Hot Channel Test (Test fluid sprayed 8 1000 psi through orifice, onto hot channel iron 8 1300F.) U.S. Bureau of Mines Approval Schedule 30 4 75 0 F 52SF 800F Pass Extinguished in less than S sec. after torch removed. Pass Yes, Number 30-6 Fire Resistance Advantages of Pydraul Pydraul fluids protect hydraulic equipment and personnel with permanent fire protection. Pydraul fluids contain no water to evaporate and leave a flammable residue. During their many mil lions of machine hours of use, Pydraul fluids have been acciden tally sprayed over molten metal, through electrical arcs, into flames and sparks without disaster. They pass all of the important ignition tests for fire resistance. "NOTE: Materials designated 'fire resistant' generally are more difficult to ignite, or once ignited, bum at a slower rate than corresponding conventional materials. This term does not mean that fire resistant materials will not bum. However, when properly used. Monsanto's fire resistant PYDRAUL0 HYDRAULIC FLUIDS are useful in helping customers meet their fire safety requirements." 0l08l`, TOWOLDMONOQ22694 9. CONVERTING MINING EQUIPMENT HYDRAULIC SYSTEMS TO PYDRAUL MC Regardless of the type of hydraulic fluid being used, con verting a system to Pydraul MC is easy. Virtually every type of equipment that uses fire-resistant hydraulic fluid has been con verted to Pydraul phosphate-ester fluids. Most equipment manufac turers are experienced in Pydraul fluid conversions and should be consulted. If changing seals is necessary, equipment manufacturers can recommend which to change, and many carry a supply of compatible seals. Laboratory tests and operational experience show Viton*, Teflon*, and silicone to be the preferred elastomers. To replace other fluids which are compatible with Pydraul and where compatible seals are already in the system, it is only necessary to add Pydraul MC as make-up fluid. It is not necessary to drain or clean. However, when converting from petroleum oils, non-compatible synthetic fluids, water-glycol fluids, or waterin-oil emulsions -- the following steps are recommended. These conform to USA Standard B93.5 -- 1973. Changing from Petroleum Oil 1. Completely drain and clean the system. Small amounts of oil will not interfere with the performance of Pydraul, but resistance to fire is reduced by the amount of oil left in the system. 2. Drain and blow out pipelines. Manually clean valves and reservoirs. `Registered trademark of E.I. Du Pont de Nemours 5 Co., Inc. 010814* TOWOLDMONOQ22695 10. 3. Open or remove-and-drain all valves. Replace gaskets; packings, and seals with compatible materials. It is particularly important to change dynamic seals. Static seals do not necessarily have to.be changed if they are tot leaking. Non-compatible static seals can be replaced . when the component is disassembled for maintenance. 4. Remove pumps, accumulators, and cylinders, if neces sary, for draining. Replace packings, seals, gaskets, and bladders with materials compatible with Pydraul. 5. Check component functions before the system is closed and fluid is. added. 6. If the system cannot be completely drained, it may have to be flushed out with a small amount of Pydraul. Changing from Water-Gfycol or Water-in-Oil Emulsion 1. Drain and clean system thoroughly. Remove all traces of water. Empty all lines and low points or dead pockets in components. ' 2. Clean with steam or warm water. Follow by blowing with dry air. 3. Check sealing materials, hoses, and accumulator bags. Replace if necessary with compatible materials. 4. Install a minimum charge of Pydraul and operate the system from 16 to 24 hours. During this period, in spect the reservoir. If water or other contaminants float to the top, remove by skimming. 01081*2 TOWOLDMONOQ22696 11. 5. Drain the flushing charge immediately after shut-down while the fluid is warm. Drain all isolated points or parts which do not drain back to the reservoir. If water is apparent in fluid clinging to walls, wipe down all accessible parts. , Ask the Monsanto fluids specialist for suggestions and assistance. He may be reached by phoning the nearest sales office listed on the back cover. * OV"ftV TOWOLDMONOQ22697 12. Pydraul MC Toxicity and Safe Handling Animal studies indicate that Pydraul MC can be classed as practically non-toxic when considered as an industrial fluid. It is non-irritating when the skin is exposed to the fluid. In case of skin contact wash off with soap and water as a hygenic procedure. In the case of eye contact flush with copious amounts of water. Due to its low order of toxicity, Pydraul MC requires no special handling precautions. * 018V TOWOLDMONOQ22698 r CUSTOMER SERVICE CENTERS AKRON, OHIO 44313 260 Springtide Drive Montroso Development Park 7d. (216) 666-4111 ATLANTA. GEORGIA 30339 320 Interstate North Parkway Suite 500 Tel. (404) 432-7711 BOSTON. MASSACHUSETTS 02149 Everett Station Tel. (617) 387-5010 CHICAGO. ILLINOIS 3158 Dcs Plaines Ave. Dcs Plaines. Illinois 60018 Tel. (312) 296-6688 CINCINNATI. OHIO 45236 8041 Hosbrook Road Tel. (513) 984-1100 DETROIT. MICHIGAN 500 Northland Towers West Southfield. Michigan 48075 Tel (313) 357-0910 HOUSTON. TEXAS 77027 1301 Post Oak Tower 5051 Westheimer Pood Tel. (713) 621-9550 LOS ANGELES. CALIFORNIA 1401 Dove Street Newport Reach, California 92660 Tel. (714) 833-9150 NEW YORK, NEW YORK 1D036 1114 Avenue of the Americas Tel. (212) 764-5000 ST. LOUIS. MISSOURI 63166 800 N. Lindbergh Dlvd. Tel. (314) 694-1000 , SAN FRANCISCO BAY AREA 2710 Lafayette Santa Clara. California 95052 Tel. (408) 243-0414 SEATTLE. WASHINGTON 98121 2112 Third Avenue Tel. (206) 622-4203 WILMINGTON. DELAWARE 19810 Suite 204. Bancroft Bldg. 3411 Silvcrside Pood Tel. (302) 478-4600 Monsanto Industrial Chemicals Co. A Unit of Monsanto Company 800 N. Lindbergh Blvd.. St. Louis. Mo. 63166 01081**^ NOTICE: "Nothing contained herein is to be construed as a recommendation to use any product in conflict with any patent^ MONSANTO MAKIS NO WARRANTIES AS TO THE! HTNLSS fOR A PARTICULAR PURPOSE. CR Ml.ROHAN l ABU t1Y 01 ANY > PRODUCT Rl l E fOH O TO, no guarantee ot satisfactory results Irorn reliance upon contained mlormnhon or recommendations' nd disclaims all liability for any resulting loss or damage." \^ tV T TOWOLDMONOQ22699