Document x5bwmdVN0B4ryq0VbvVvoLw00
Monsanto < Mt* iNkM.1 KlWUtf R. E. Hatton - St. Louis-B2SD
OIMI September 15, 1976
WN/iei
PCB/PLESSEY-DUCON
rfttiMc< '
TO :
GWO to DW, 9/9/76 G. W. Oxer-5020 *
QI f(jb
R. F. Garnsworthy-5020 D. Hood
Subject memo requests information on chemical methods to convert PCBs to easily disposable products. A number of methods have been proposed and reported in the litera ture. The only one to achieve commercial and practical success that I know of is incineration (complete oxi dation) under conditions insuring conversion to hydrogen chloride, carbon dioxide and water with removal of the hydrogen chloride from the gas stream before exhausting to the atmosphere. Such conditions are covered in the Askarel Guide. Incineration is used primarily for liquids with solids being placed in landfills approved for disposal of toxic and hazardous substances.
Recently, work has been underway to dispose of PCBs by destruction in cement kilns during cement production. The U,, S. EPA has sponsored some tests and their report should be available in the near future. Details are now proprietary with the company doing the work.
Other methods besides oxidation for PCB destruction that have been suggested are removal of chlorine by various reductive technics, photodegradation and attack by micro organisms. The attached copy of an article describes one company's attempt to commercialize a new reductive system 1 have had no report on experience with the unit.
Please let me know if you have further questions. Unfor tunately, there are no easy, cheap methods to get rid of PCBs.
/deb Attachment
R. E. Hatton MQNS 031340
* ?IN l l I 7
Process gobbles up chlorinated compounds
| 1r
ThU cHalyted reduction tyitem remove! chlorinated pcHirUtot from effluent trem. And lc*idktt ;
dua&croetWmy^ff<^vetntitfl|iJMof
PCB* nd reportedly carcinogenic "light endi,1* too.
Q Thii treatment process, which uses a catalysed-iron reducing agent, reduces the small amounts or water* soluble chlorinated compounds found in effluent streams of plants making or using such substances to within acceptable federal limits. These effluent streams, generally containing I ppm or less of chlori nated toxicants, are difficult to treat economically because of the low con* centrations of the materials. But Held tests at a chlorinated-pesticide plant have shown that the firm's ca talysed reduction system can lower the chlorinated-compound concen tration of an effluent stream from 100 ppb-1 ppm to 10 ppt-l ppb.
Laboratory tots conducted by the manufacturer show that materials amenable to the system's reductive degradation method indude: cydodiene pesticides, such as aldrin, diddrhk, and endrrn; DDT and related matwiab, such as DDD and methgayohlor; the chlorinated camphene, tniaphimn; the chlorinated cydo* bnanat Haldane; and the chlorinated
phenoxyacetic-add beririddes, 2,4-D and 2,4,3-T. Indications have also been seen, says the oompany, that the system can also remove "light ends," such as chloroform, carbon tetrachloride and ethylene dlchloride. And the firm Is optimistic that the process can reduce polychlori nated biphenyl (PCB) levels in ef
fluent streams. In recent tests, the treatment system reduced the PCB concentration of an effluent stream from a saturated level of 200 ppb to 1cm than 1 ppb.
The firm estimates rite total cent of the system (reagents, operator, main tenance and supplies, utilities and amortised capital investment) to be about 10.72/1,000 gals treated, based on a 100-gal/min unit (photo). The units come skidmounted and consist of 25-gal/min modules. Thus, If a plant expands, additional modules may be added to maintain required capacity. For very Urge treatment systems, laiger-than25-gal/min modules can also be fabricated.
STRAIGHTFORWARD PROCESSTreatment begins (see flowchart) with a Alter that can be a cartridge, sand, caibon or other type, depend ing on the characteristics of the ef fluent being handled. Additional
flowstream purification, such as oil
removal, etc., would also be done at this point. Following pH adjustment (the company indicates the optimal pH is 7), the effluent is metered into a reduction column that contains an iron powder (100-200 mesh) reductant in a sand-bed matrix.
The maker uses an unidentified metallic catalyst that attaches to the iron and enhances the reduction re action. According to the company, the catalyst gives a more complete reaction by speeding up the reduc tion and limiting the number of in termediates formed.
bon powder coats about S0.28/lb, and the catalysed iron powder just a few pennies more, according to the manufacturer. Because of the small amounts of toxicants actually re moved, the reduction bed should Iasi a long time before needing replace ment; the present estimate for a 100gal/min unit is a year or longer. The
CttfcMX'Al SMUMSKMNU V.'tR.'ST tl>. I76
*.1
SNOW
;N5W products vservices;
bpd for such a unit contains 3,000 lb
of iron powder and 12,000 lb of
and.
Other metal roductant* besides
iron itiay be used, but the maker
notes that the use of iron avoids tox-
Jetty problemi connected with other
metals.
COMPATIBLE SYSTEM--The treat
ment system operates at ambient
temperatures. A small pressure, sup
plied by a pump, is sometimes
needed to regulate flowrate. Mate
rials of construction vary to meet the
needs of individual effluent streams.
The manufacturer sells complete
systems and will provide startup as
sistance as needed.--Emrirogenics Sys-
tmt Co., ElMonte, Calif.
351
Digital thermometer
About the tin of a pocket calculator,
the Model 232 hand-held, digital thermometer it precalibrated to No-
tlonal Bureau of Standards specifica
tions and needs no zeroing or range
election.
Using standard batteries, the in
strument features a display readable
to 0.1'F and is accurate to 10.5*F
across its range of -55 to 240'F.-
Vertronix, Inc, Evergreen, Colo.
364
Syrup/water Analyzer
Intended for use in the beverage in dustry, the Model SR meter checks the syrup/water ratio of sugar- and nonsugar-swoetened soft drinks. Measurements can be made in lea than 3 min-includlng sample prep aration--says the maker. Accuracy and repeatability are within 1%.
The instrument uses two built-in cells to compare the conductivity of a lab-prepared standard to that of a
Containers go out full, come back flat
Suitable for handling most types
of bulk or packaged materials,
these 50-ft*, rectangular, metal
containers can be knocked down
to occupy minimum space during
return shipment. The containers
are made in two gages of
aluminum: for one* and two-ton
loads. Container tare weights are
131 lb and 170 lb, respectively.
With plastic lids, the containers
can be stacked two high; standard
dimensions are 60 X 44 H X 39'A
in. A polyethylene bag, a rubber
bladder, or some other material
can be used as s liner, if so
desired. Fourteen knocked>down
empties are lea than 8 ft high.--
tfomrBattmMBoormgCn, ToU .
ftifimi Di*, Beotnce, Nek
933
sample from the production line. Meter readout is in percent confor mation, with 100% being equivalent to no deviation from the standard. Portable and powered by a 9-V bat tery, the instrument weighs less than 2 lb. The unit measures 6X4X5 in.--Myron L Co., Encinitas, Calif 354
Acrylic processing-aid
Now commercially available is
Acryloid K-125, an acrylic process
ing aid for rigid vinyl compounds.
Claimed to be at least 20% more ef
ficient than conventional processing
aids, the acrylic is said to produce no
deleterious effects on the thermal sta
bility and physical properties of vi
nyl compounds.
Suitable for use in the manufac
ture of vinyl pipe, sheet, film and in
jection-molded fittings, Acryloid
K-125 is cleared for inclusion in
semi-rigid and rigid vinyl food-pack
aging materials under FDA Regu
lations 21 CFR 121.2597--Rohm and
Haas Co., Philadelphia, Fa.
355
Programmable calculator
The HP 9830B programmable, daktop calculator is a more-powerful version of the firm's HP 9830A unit. Using a newly developed semicon ductor memory, the calculator comes with 15,808 bytes of read/write memory and built-in
string-variables and matrix-oper
ation capability. The memory can
be expanded to 30,144 bytes.
Featuring a built-in tape-casrette
drive, the calculator operates in
BASIC language and has an alphanu
meric keyboard and display. Avail
able peripherals include line print
ers, impact printer/piotten, plotters,
paper-tape puncher and readers,
digitizers and a 4.8-megabyte mass
memory.--Hewlett-Packard, Palo Alto,
Calif
362
Three miniature cameras for closedcircuit television systems are now available for wet and dry inspection applications.
The Imlec V-150 System camera is IVi in. in dia. and incorporates a conventional vidteon tube that's rec ommended for inspecting flaws and minute cracks in dry, nonexplosive environments. Said to be unaffected by temperature or vibration, the sys tem consists of a camera head, 100 ft
HONS 0 3 1 3 4 2