Document x5V05yedbrxX44LLOgXNv7Gx1
i Constructed of rugged, corrosion-proof, time-proof cast iron, the Model L Arcoflame by American-Standard is a high-pressure, heavy-duty oil burner for flexible, dependable application with heating units in commercial buildings, apartments or large residences. In addition to dependable durability, all Model L components-motor, transformer, fuel pump, firing mechanism-are carefully designed and integrated for the quietest pos sible operation over the entire firing range of 3 to 7 gallons per hour. Model L burners also feature remarkably clean, economical fuel consumption-with quick starts and quick cut-offs that avoid waste. The two-stage fuel unit pumps air-free oil; the precision-built nozzle provides accurate atomization; primary air volume is accurately and easily controlled with a simple adjustment of the air shutter. The Model L is available with either pedestal or flange mounting and is easily installed to convert any boiler or furnace within its capacity range to automatic oil-fired heating. A complete selection of versatile control combinations is available for all types of hot water, steam or warm air installations. Thorough laboratory and factory testing programs for Arcoflame oil burners assure conformance to American-Standard requirements for peak operating performance.
00056
l N ovem ber, 19SV|
ouis;~nama sesian acTures
3 Mcmoo zi jei timiuiiiri mechanical pressure --100 pounds. 3 a;- -c=- . - low pressure with squirrel cage fan. 3 - intermittent or constant spark.
3 Notzie--hollow cone, 80 spray angle for 3 to 4Vi gph- 60 spray angle for 5 to 7 gph. Each nozzle tested at factory.
3 Two-stage fuel unit - standard equipment on the Model L.
.3 Controls--available for all types of hot water, steam or warm air requirements.
cirrtsf
moci2! .
i.rcj-
model LF-A (flange mounted) i,
dimension
L*1
A 24% B 11%
diameter air tube-6'
L-3
34% 21
LF-A
20% 6%
current characteristics
gallons oil per hour
minimum
maximum*
motor
hp rpm
115 volt 60 cycle
3.00
7.00 % 1,750
These capacities can be used up to 1,000 feet altitude. Reduce capacities by 4% for each additional 1.000 feet above sea level.
oil pressure
(psig)
100
^ All Arcoflame Oil Burners (60 cycle, 115 volt) are listed by Underwriters' Laboratories, Inc. for
No. 1 and No. 2 grades of fuel oil, distillate or catalytic cracked, and comply with Commercial Standard CS-75. They are approved by the New York City Board of Standards and Appeals, the State Fire Marshal of the Commonwealth of Massachusetts and the Department of State Police, State of Connecticut.
00057
American-Standard plumbing and heating division
AMERICAN RADIATOR & STANDARD SANITARY CORPORATION 40 WEST 40TH STREET NEW YORK 18, NEW YORK
litho m U S <