Document x5QXJ8Q1RpqBKGzYk9399mymg
H-tO mCC
Monsanto
^1 LOCA,'"1
UrtJfCT t'EttMCf
TO
J. M. Gatewood
April 10, 1985
Second Quarter Safety and Housekeeping Inspection
R. H. Benson D. N. Canpbell B. P. Curtis R. M. Fritz R. M. Gibbs Phil Johnson J. R. McGinty
D. K. Pease R. R. Purgason W. R. Rolingson A. K. Uriarte K. S. Wbgoman
ec, G. Bostick
W. M. Haynes W. G. Juhl P. K. Saunders D. R. Wise G. L. Wbfford
Inspection Team: G. W. Daues Glenn Olson L. Inskeep
SHAC
D. Barfoot R. Coleman J. Gatewood B. Hammann B. Sanders R. Sharp
The Second Quarter competitive Safety and Housekeeping Inspection for the lab area was conducted on April 9, 1985. The Quality Assurance T^h will be given the outstanding award and the best rating for this quarter. While the Research III area did just
C get into the outstanding level the inspection team did not feel that it should merit an award plaque. Ratings were:
Quality Assurance Lab Research III Research II Research I
Outstanding Outstanding Good Good
GENERAL COtttEOTS
Many of the rocms in Research I and Research II buildings are in need of interior painting and window glazing.
Several labs were very cluttered and housed more apparatus than available storage space.
Several labs were vacant with apparently no one responsible for housekeeping or cleanup.
Emergency utility cut-off drawing in Research I and Research II halls have not been revised in twelve years - need to check to make sure they are current and revise date.
QUALITY ASSURANCE LAB
North Lab
Old 2" solvent line on outside of building is badly corroded and needs to be removed.
Kitchen area - ice box needs to be straightened up.
SC 000339
LAM001536
RESEARCH III - PETS
Designated areas or boxes need to be provided for face shields. Area in back lab where bar stock and metal is stored needs to be straightened up.
RESEARCH II
Conference Room Boxes stored on floor.
Lobby
Respirator fit sign - loose on wall.
Hall by Storeroom 1/2 copper tubing loose and hanging
Back of Building Plectron radio turned off. First Floor
Research Store room
Eyebath and safety shower not accessible.
Lab 2105
Lab crowded and cluttered.
Lab 2113
General clutter in lab and office. Hood door too high.
Lab 2114
lab dirty, lapp pumps dripping oil on floor.
Lab 2142 Lab 2143
Emergency card on door needs to be updated.
Emergency card needs updated. Hood above recctnnended set point. Many samples on counter, ladder should be stored. Need coat rack.
Lab 2145
Shelves need straightening up.
Lab 2148
Hole in window.
Cell 3 and Bench 2
Water dripping on floor.
Lab 2106
Beaker of material on shelf covered with aluminum foil.
2140 Xerox Room
Trash in comer. Scott air paks - need inspection
lab 2128
Glass bottle for drain - could be kicked over
SC 000340
LAM001537
RESEARCH II Cont'd. Lab 2136
Air Condition Building High Pressure Lab Maintenance Shop Cell Areas
RESEARCH I Main Entrance
Lab 1109
Lab 1105 Lab 1204
Lab 1205 Lab 1206
Lab 1308
3rd Floor
Need N2 hose rack south side of lab. Trash in south side.
Radioactive material drum - has corrosion
Need boxes for face shields.
Ladder wired off to pipe. /
Cracked window. Needs painting. Calculator plugged in hood. Paper cutter no latch - second violation. Name on door tag out of date. Clutter on floor. Drawers need to be straightened. Painting and caulking of windows. Window broken. Need clothes rack. Needs to be straightened up. Plectron radio turned off. Stock roan wire hanging outside conduit .
Please respond to the cements in your area to W. G. Juhl, R. L. Hammond, G. Bostick, and Doug Barfoot by May 15, 1985.
SC 000341
J. M, Gatewood, SHAC For the Inspection Team:
G. Daues G. Olson L. Inskeep B. Hammann
LAMOOI538