Document x5ByB9zXo211O37GgjrkB3NEm
, : 5-10 11/74
, ,
APPLICATION: An Industrial, high temperature single or multi-cattductor cable for use around furnaces on mud guns, around open hear#* and blast fur*
naces, and where extremely high temperatures and occasional- flaafcs may envelop the wires. Its relatively small diameter allows for use in close ^Arters. Its ex cellent flame resistance; extremely high radiation rss'stance? arid its retention of flexibility at cryogenic temperatures provide additional performance capabilities to broaden its range of usefulness.
ADVANTAGES: Mica, glass and asbestos are inorganic materials`which cannot melt, soften, smoke or burn. Mica, protected by glass, provides the elec
trical properties. The tough outer covering of impregnated asbestos provides the . mechanical protection. Together they provide the high temperature, flame and I radiation resistance and electrical properties necessary in extremely abusive en-
viroriments.
Size
Stranding
Max.Bare 0.D.(Inches)
Max.Resist. @ 20C
Ohms/1000 Ft.
. .Norn.Fin. 00 (Inches)
Approx. Wt.
Lbs/1000 Ft.
14 19/.0142" 12 19/.0179" 10 7x7/.0142"
8 19x7/.0113"
6 19x7/.0142" 4 19x7/.0179" 2 19x35/.010" 1 19x43/.010"
1/0 19x55/.Q10" 2/0 19x70/.010" 3/0 19x88/.010" 4/0 37x57/.010"
350 19x7x26/.010" 500 19x7x38/.010"
0.074 0.093 0.1280.176
0.218 0.272 0.3^5 0.384
0.432 0.490 0.548 0.615
0.809 0.988
4.32 2.68
.1 59
0.936
0.591 0.375 0.241 0.196
0.153 0.120 0.096 0.077
0.048 0.033
.160 .180 .230 .265
.310 .370 .470 .525
.580 .615 .675 .740
.950 1.140
21 30 54 77
114 169 265 325
400 535 650 790
1275 1785
A. nickel clad copper B. glass reinforced mica C. asbestos braid impregnated
*Wi11 operate with conductor temp, of 650C without damaging cable for short term
with high temperature finisher
emergency overload conditions.
RBB 02848
CERRO WIRE & CABLE CO.
0 I V I S l O N OF CEBRO CORPORATION
NEW HAVEN * CONN 06 5 0 *
; I
I
The ampacities shown are based upon 60 cycle alternating current, sea level conditions.
Ambient Temperature of 2C0C (392*F) Conductor Temperature of 400C (752F)
Conductor Size
Ampacity - Single Conductor in Free Air
u 26
12 35 10 50
8 70
6 100 4 130 2 175 1 200 1/0 235 2/0 275 3/0 315 4/0 365
350 535 500 74C
Note: To determine ampacity for 3 close cables, multiply single wire ampacities by Q.60.
CORRECTION FACTORS FOR AMBIENT TEMPERATURES ABOVE AND BELOW
200C (392F)
Ambient Temperature
Multiplying Factor
C F
100 212 150 302 200 392 250 482 300 572
1.22 1.12 1.00
.87 .70
BEND RADIUS
The recommended minimum bending radius is ten times the overall diameter of the wire.
RBB 02849