Document x54bznQx88JKajgkw4DmqMZNQ
r.
National Radiator Corporation
Boilers and Radiators
National Bonded Super-Smokeless Boiler
Distinguished for its swirling scarlet flame, this boiler is scientifically designed for the efficient and smokeless combustion of all grades of fuel. The green coal cokes on the front of the grate-- the distilled gases pass back to unite with pre heated, proportioned, finely divided, and fully distributed secondary air, and are completely consumed.
i-
Steam
Water
Chimney
1 i j
Steam ' Boiler
No.
Avail able Output Rating
Sq. Ft.
Bonded
Direct C. I. Radia- . tion
Sq. Ft.
Water Boiler
No.
Avail
able Output
Rating
Sq.Ft.
Bonded Direct
C.I. Radia
tion Sq.Ft.
Crate Area Sq. Ft.
Length Sections Number Sections and Outlets,
Only Smoke Sizes In. Box In. In.
{Boiler
Covering Area Height Sq. Ft. In. Ft. Surface
24 Stria--Hdlht of Wcla Lint. 45'/i". Htithl Fba Otdlti. 54". Width of Section. 35'/2". She Smoke Pipe. 14".
S-245 1,600
700 W-245 2,600 1.155 5.00 37% 463/4
1-4 12x12 40
34
S-246 2,000
925 W-246
3,250 1,525
6.25 45%
55
2-4 13x13 40
42
S-247 2,400 1,150 W-247 3,900 1,900 7.50 53% 63%
2-4 13x13 45
50
S-248 S-249
2,800 1,375 W-248 3,200 1,600 W-249
4,550 5,200
2,270 2,640
8.75 62 10.00 70%
71% 79%
2-4 14x14 50
58
3-4 14x14 55 - 64
33 Series--Height o Water Line, >3*. Height Fbu>, 64i/i". Width oj Section, 4i". Size Smoke Fine, 16".
S-335 2,900 1,300 W-335 4,650 2,150 7.32 37% 473/4
1-5 14x14 40
42
S-336 S-337
3,600 1,650 W-336 4,300 2,000 W-337
5,800- 2,725 6,950 3,300
9.10 10.67
4553%$
56 64%
2-5 15x15 40 2-5 16x16 40
51 60
S-338 5,000 . 2,350 W-338 8,100 3,875 12.65 62
72%
2-5 16x16 50
69
S-339 5,700 S-33IO 6,400
2,700 W-339 9,250 4,450 3,050 W-3310 10,400 5.025
14.42 16.20
70'/, 78%
80% 89
3-5 18x18 50 3-5 18x18 55
78 87 ,
40 Series--Height of Water Line, 57". itight ttoio Outlet, C 9". Widt i of Section, 57Vi"> Size Smoke Pine. 20*.
S-406 5,200 2,300 W-406 8,300 3,795 12.03 . 45% 55%
2-5 16x16 50 '
50
S-407 S-408
6,200 7,200
2,800 W-407 3,300 W-408
9,900 11,500
4,620 5,445
14.38 16.73
53% 62
65 72%
3-5 18x18 50 3-5 18x18 55
66 76
S-409 8,200 3,800 W-409 13,100 6.270 19.08 70% 80%
3-5 20x20 55 ^ 86
S-4010 9,200 4,300 W-4010 14,700 7,095 21.43 78% 88%
3-5 20x20 60
96
S-4011 10,200 4,800 W-4011 16,300 7,920 23.77 86% 97
3-5 21x21 60. 106
S-4012 11,200 5,300 W-4012 17,900 8,745 21.43 95
105%
4-5 22x22 65
116
S-4013 12,200 5,800 W-4013 19,500 9,570 .21.43 103% 113%
4-5 22x22 70
.126
S-4014 13,000 6,300 W-4014 20,800 10,395 23.77 111% 121%
4-5 23x23 75
136
S-4015 13,800 6,800 W-4015 22,100 11,220 23.77 119% 130
4-5 23x23 75 ` . 146
S-4016 14,600 7,300 W-4016 23,400 12,045 23.77 128
138%
4-5 24x24 60
156
S-4017 15.400 7,800 W-4017 24,700 12,870 23.77 136% 146%
4-5 24x24 80
166
S-4018 16,200 8,300 W-4018 26,000 13,695 23.77 144% . 1543/,
4-5 25x25 80
176
S-4019f 17,000 8,700 W-40l9f 27,300 14,355 23.77 152% 163
5-5 25x25 85
186
S-4020t 17.600 9,100 W-4020t 28,200 15,015 23.77 161
171%
5-5 25x25 90 196
S-4021T 18,200 9,500 W-4021t 29,200 15,675 23.77 169%
5-5 25x25 100
206
S-4022{ 18,800 9,900 W-4022f 30,200 16,335 23.77 177% 187%
6-5 26x26 100
216
S-4023f 19,400 10,300 W-4023t 31,200 16,995 23.77 185% 196
6-5 27x27 100
226.
S-4024f 20,000 10,700 W-4024T 32,200 17,655 23.77 194
204%
6-5 27x27 100
236
National Bonded Imperial Sectional Boilers
32 Series--Height ef Water Lint. 53*. Height of Top Outlet. 6f*/j*. Width of Section, 47". Site Smoke Pipe, 16".
S-532 S-632
2,900 1,200 W-532 3,600 1,500 W-632
4,650 1,980 5,800 2,475
7.32 l 37% 9.10 45%
47% 56
2-5 14x14 40 2-5 15x15 40
S-732 4,300 1,800 W-732 6,950 2.970 10.67 53% 64%
2-5 16x16 40
S-832 5,000 2,100 W-832 8,100 3,465 12.65 62
72%
2-5 16x16 50
S-932 5,700 2,400 W-932 9,250 3,960 14.42 70% 80%
3-5 18x18 50
42 Series--Height of Water Line, 57". Height of rop Outlet, 69*. Width of Section, 57%' . Size Smoke Pine. 20
S442 5,200 2,200 W-642 8,300 3,625 12.03 45% 55%
2-5 I6xl6 50
S-742 6.200 2,700 W-742 9,900 4,450 14.38 53% 65
2-5. 18x18 50
S-842 7,200 3,200 W-842 11,500 5,275 16.73 62
721%
3-5 18x18 55
S-942 8,200 3,700 W-942 13,100 6,100 19.08 70% 80%
3-5 20x20 55
S-1042 9,200 4,200 W-1042 14,700 6,925 21.43 78%
3-5 20x20 60-
S>1142 10.200 4,700 W-1142 16,300 7,750 23.77 85% 97
3-5 21x21 60
S-1242 11,200 5,100 W-1242 17,900 8,400 26.12** 95
105%
4-5 22x22 65
S-1342 12,200 5,500 W-1342 19,500 9,050 28.47* 103% 113%
4-5 22x22 70
S-1442 13,000 5,900 W-1442 20,800 9,700 30.82* 111% 121%
4-5 23x23 75
S-1542 13,800 6,300 W-1542 22,100 10;350 33.17* 119% 130
4-5 23x23 75
S-1642 14,600 6,700 W.I642 23,400 11,000 35.52* 128
138%.
4-5 24x24 80
42 51 60 *69 78
. 56 66 76 66 96 106 116 126 136 146 156
Maximum grate area which can be furnished. Unless otherwise ordered these sizes are shipped with 10 grate bars
having a grate area of 23.77 sq. ft. "Shipped with 9 grate bars having area of 21.43 sq. ft.
{Square feet of exterior boiler surface. Approximate number of pounds of covering per boiler section. 24 series, 50 lb.; 32 and 33 series, 60 lb.; 40 and 42 series, 67 lb.
tRecommended only for oil burning on ordinary stack.
600
Newport Boiler Company
General Offices: 529 S. Franklin St., Chicago
Boilers
MAGAZINE FEED
OIL BURNING
PiBTftrouTOBS--*A11 Prinripal^itigg_UnitgdJjitatesjin(^Cana^
This boiler cuts fuel bills from 30 to 50 per cent burning No. 1 Buckwheat coal
"Newport"---alone, provides these Heater essentials:
-- Coaling only necessary from once a day to once a week, depending upon
Convenience the weather. It is therefore the Home Owner s choice.
r* "Newport" combustion is complete, conforming to all the laws of science.
economy Saves from $5 to $7 per ton, burning No. 1 Buckwheat coal.
Uniform MeatF7 /
I7,,,,i U provided by the never varying thickness of the fuel bed that supplies heat for every nook and corner, automatically controlled.
av
thr* natented. _j.+ * *
-- '--1
NEWPORT COAL BURNING BOILERS
Boiler Number
Steam
Rating
Square Feet
Maximum
Radiation Load
Boiler Number
Water
Rating
Square Feet
Maximum
Direct Kadiation
Load
Length Overall
STEAM
S-4
S-5 S-6
S-7 S-8
S-55 S-66
S-77 S-88
SsS---19f0911101
594
750 907 1063 1219 1375 1688 2000
2313 2625 2938
3250
'
340
430 518
607 696
786 965 1143
1322 1500
1679
1856
W-4
W-5 W-6
W-7
W-8 W-55 W-66
W-77
W-88 W-99
W-1010
W-1111
WATER
1000 1250 1500 1750 2000 2282 2782 3313 3813 4313 4813 5313
572
714 857 1000
1143 1304
1590 1893 2179
2464
2749
3035
30%'
36%' 42% 49 55%' 44' 50%' 56%' 62%' 69*
75%' 81%'
Width Overall
32' 32' 32' 32' 32' 56' 56' 56' 56' 56' 56' 56'
Chimney Flue
Size Inches
8x 12 8x 12 8x 12 12x12 12x 12 12x12 12x 16 12x16 16x 16 16x 16 18x18 I8x 18
Height Feet
35 35 40 40 45 40 45 . 45 50 50 50. 55
NEWPORT OIL BURNING BOILERS
O-S-4
O-S-5 O-S-6 O-S-7.
O-S-8 O-S-55 O-S-66 , O-S-77 O-S-88 O-S-99
O-S-1010
O-S-llll
594
750
907 1063 1219
1375 1688
2000
2313 2625 2938
3250
340
430 518
607 696
786
965 1143
1322
1500 1679
1858
O-W-4 O-W-5 O-W-6 O-W-7 O-W-8 O-W-55 O-W-66
O-W-77 O-W-88 O-W-99 O^W-101C
O-W-111!
1000
1250
1500
1750 2000 2282
2782 3313
3813 4313
4813 5313
572 714 . 857
1000
1143 1304 1590 1893
2179
2464 2749
3035
30%'
36%' 42%' 49*
55%' 44'
50%'
56%' 62%' 69*
7574' 81%'
32' 32' 32' 32' 32' 56' 56' 56' 56'
56' 56'
8x 12
8% n
8x12
12 x 12 12x12 12x12 12 x 16' 12x 16
16x 16 16x16
18x 18 18x18
35
. 35 40 40
45 40
45 45
50 50
50
,, 55-
tpu- MfiTimtim Direct Radiation
TM maximum actual amount of square feet of cast iron column radiation
r it^uiv^Zrw^m"teaSed to boiler. This amount providesasafety factor of**1ter ugh
for average conditions, to take care of the load imposed by mains risers, etc:; but does notprovidean aijowanCTf^theJ^tang
of water fo--r d->o--m--e--s^tic---u--s-e--,-o--rany extra load where attached radiation will condense more man 0.25 \yi) to. of steam, per
square foot per hour. 'The water line on all Steam Boilers is 40in.
Height overall Coal Boilers 62 in.
Oil Boilers
in.
601