Document x52GwKXRMqbzpVy6LMgYJ6E0G

vw; vm- v . American Society of Heating and:Ventilating Engineers Guide, Each of these main columns is further divided into three smallercolumns, thee* one of which is left blank for recording the test data. To the left of this isthe scaM the individual factor, effective temperatures in degrees, dust in particles per cubic f carbon dioxide in parts pier 10,000, etc. On the right of each central ^column is't penalization scale. This is arranged with main graduations of 1 per cent which 1 numbered. Each graduation is further subdivided into fifths so that' the scale may3 ' read to 0.2 of 1 pier cent on the scale, or by interpolation to 0.1 per cent. y The chart gives not only final percentage of the test as a whole, but also indicat at a glance which factors are satisfactory and which at fault. In this way it is a venient guide in correcting bad conditions, and bringing the final percentage up to th" point desired. e Making .the Test In making a Synthetic Air Chart test the observer first divides the room by imaginary lines into small sections, each section having an area of approximately 200 sq. ft, 0{ floor space. He locates an observation station in the center of each section. Takim so- ss- eo- os- xr rr oo- as- so- ss- JDry &/ft>. 7eatfitro/urt Fig. 9. Relation between Heat Loss from the Human Body by Evaporation, Radiation, Convection and Dry-Bulb Temperature school classroom for example, the room should first be divided into four equal rec tangular areas by imaginary lines bisecting at right angles through the center of the room. (See Fig. 11.) Four stations are now selected, one at the center of each rectangle. These stations are numbered 1, 8, 8 and 4- It is always well to use a standard method of numbering stations, so that whoever reads the report can visualize each location. Standing at the rear of the room facing the teacher's desk No. 1 is the station nearest the teacher at her right. No. 2 is the one directly back of No. 1. No. 8 is the station nearest the teacher at her left, and No. 4 the remaining station. The tests are conducted in the following manner: Column A.--A Psychrometer reading is taken at each station beginning with 1, following with 2, 8 and 4- The wet and dry-bulb readings are separately recorded on the data sheet (Fig. 12)* for each station. Column B.--Dust determinations are next made at stations 1, 2, 8 and 4, and the count of particles per cubic foot recorded from each station. The scale of the chart is arranged for a direct reading dust counter. If some other type of instrument is used, a correction factor is, of course, necessary. Column C.---Culture plates are next exposed to determine the bacterial content of the air. One plate is exposed at each station for two minutes, incubated, and the colonies that develop are counted and recorded for each plate. The average of all plates is plotted on the chart. 4X2 -Mt- chapter ^ventilation Standards r Mvp: __' Odor determinations are made of the loom as a whole. should go outside of the room or preferably outside of the building for jnm. ments preV]ous to making the test. He then enters the room quickly, and determinations of the air in the classroom by means of the olfactory sense, ms.hts.L,, results whether perfect, very faint, noticeable, etc., in accordance with ^fuofoflllliolaowgwiing ta`Tb,le >3?:^ 95%-- ^JWfcCt Very Faint ftreedaogm fj,fr-vo--mm- O_dors 90%............ 85% 8Q% Faint Noticeable Distinct 75% Decided . 70% Strang Si fkiorometer consists of a case of six vials each containing an odor substance in r :An vJao adds materially in classifying and standardizing odor perception. *S^?r=CAvuniosn"elOuSg,mdhs.oont^rrwoefEueSnK.v--g.re<t-hr.S--,'.iaissmI.ntpolaetdsidmospfmearaiartteiavrreiae.llnye.x.-.t .t-a--k--e--n-- at each station, and carbon dioxide, and results of this analysis plotted in Column E in later part s analyzed i-n-- m10,n0o0n0. for ^`Column F.--Distribution of the air in the room is determined from the CO* analysis fa,'r"r;^*rv^*,t'o:aClurToe~blnu-eamftonthlloFew.v--ianrDgioeiusxstansmotaputluieovnil*lsu.stra.tes the method of making the cal'c-uillaattiioonn:: COa Stations Variations from the Average 1..... ................... 1111.1.1 --1100.2.2= 0.9 2........... .10.2 - 9.4 = 0.8 3--...... ,10;4 - 10.2 = 0.2 4.-.......... 10.2 - 9.9 - 0.3 - 9.9 Total 2.2 ,1-v Total 40.8 Average 0.55 Average 10.2 . .. -0--.55 X--1-0--0-- = .5...4. = per cen.t of, variation. <y' 100 --l5v.4.i -- 94.6 = final per cent of distribution. After the tests have been made as described, the observer completes his test by a g study of air motion and air currents. This is done by liberated puffs of ammonium S^chloride in different locations in the room with a suitable apparatus. Observations of the ^velocity and direction of travel of these small artificial smoke clouds add materially in obtaining a true conception of the velocity and general behavior of the air currents in the room. ` i -PlTohtteinrgestuhlets Toef stht eDtaetsats are plotted in each column as previously described. The ^.following data from the test illustrated on the chart on page 414 will make the entire . ' proAcveedruargeecDlerayr-:Bulb temp. 75 deg.--Wet-Bulb temp. 59.7 deg.--Effective temp. 67.4 deg. AEvffeerc.tiDveustet mCpo.unDtiffo. r34.4Sdteagti.o--nsP--lo7t,0in00CpoalurtmicnlesAp. er cu. ft.--Plot in Column B. Aver. Bacteria {or 4 Stations -- 3.5 --Plot in Column C. Aver. Odors Percentage --90 per cent --Plot in Column D. Aver. CO2 -- 10.2 --Plot in Column E. t . Distribution Per Cent -- 94.2 per cent --Plot in Column F. Adding the penalization for these'factors found at the right of each column and sub tracting the sum from 100 gives a final percentage of perfect of 84.7, which is plotted in the last column. TESTING METHODS AND INSTRUMENTS TeImnptehraetumreesasuring of room temperatures care must be exercised to pre vent the results from being, affected by the body heat of the observer, by drafts from doors,, windows and other openings or by radiant heat 413