Document x4EJpdj79D1vbmvQznyqY9yG
Air Conditioning Systems
Gar Wood Industries, Inc.
AIR CONDITIONING DIVISION
7924 Riopelle Street, Detroit, Mich.
Licensed Distributors in All Principal Cities
TEMPERED-AIRE UNIT
Tempered-Aire heating and air conditioning equipment includes fil ters, blower, humidifier, furnace (with "Economizer") and integral oil burner of pressure atomizing type. Cloth filters can be easily, laundered. AH units can be equipped with a water heating coil for use in winter. The installation of an auxiliary duct for intake of outside and basement air in summer is desirable. Air can then be drawn from the basement during the day and from the outside at night to provide ventilation and cooling during warm weather. Change from basement air to night air may be manually or automatically controlled.
Ratings and Dimensions Btu 1 Hour at Bonnet..................................................... Btu 1 Hour at Grilles................ ......................................
Air Delivery, CFM............................................................
Heating Surface. Firebox, Square Feet..................... Heating Surface, Economizer, Square Feet............. Total Heating Surface...................................................... Overall Length; Inches..................................................... Overall Width, Inches......................................................
No. 102 120,000
100,000 1000 to 1575
30 60
90 96%
-40
No. 103 165,000 135,000
1375 to
2150 33 99
132
117% 40
No. 104 225,000
185,000 1875 to
. 2950 44
132 176
140'/,
40
No, 105
300,000
245,000 2500 to 3925 55 165 220
156'/, 40
No. I0S-C 400,000
3000 to
'4500 55 165 220
156% 40
CONVERSION OIL BURNER--Pro vides automatic oil burning equipment for coal fired heating plants. Pressure ato mizing type, handle heavier, cheaper grades of fuel. Sturdy, noiseless, easily accessible.
MODEL "0" AUTOMATIC OIL FIRED WATER HEATER--Provides quick, convenient, less expensive and un limited supply, of domestic hot water for industrial and commercial buildings. Com plete, quiet. Burns low priced No. 3 fuel oil.
Model "K" Extremely flexi ble, due to system of triple range blowers and two motor speeds. Handles capacities from 412 to 2500 sq ft net steam radiation.
Model "H"
An efficient, low cost unit, to supply automatic oil heat for small homes. Handles capacities up to 625 sq ft net steam radiation.
Capacities and Dimensions
Two sizes, 200 and 300 gal ca pacity. 100 F rise per hour.
Overall height 48 in.
Overall width 28K in. . -
Length 49 in. and 61 in. re spectively.
836-
Car Wood Industries, Inc.
Air Conditioning Systems
MODEL "R" BOILER-BURNER UNIT
A compact, fire-tubular steam or hot water heating boiler, with an integral oil burner.
Boiler built of heavy rust-resisting boiler plate, electric ally welded. The combustion chamber walls are carried clear to the crown sheet. The result is a considerably higher temperature of fire than is found in the conventional boiler, and better combustion of No. 3 oil.
Since there are no water legs, the bulk of the heating surface is concentrated in the firetubes, or secondary heating surface, resulting in maximum extraction of heat from the hot gas which leaves the firebox and consequent low stack temperature, high efficiency and operating economy.
Ratings and Dimensions Maximum Net Steam Load, Square Feet................ Maximum Net Hot Water Load. Square Feet-----Maximum Gross Steam Load, Square Feet............ Maximum Gross Hot Water Load, Square Feet. Heating Surface. Squire Feet....................................... Overall Width, Inches..................................................... Overall Length, Inches..................................................
R475 475 760 712 1140 52 30% 53
R750 750 1200 1125 . 1800 68 30% 65
RI000 1000 l`00 1500 2400 84 37% 59%
RI400 1400
' 2240 2100 3360 118 37% 66
RI800 1800 2880 2700 4050 ' 154 37% 80
MODEL "J" BOILER-BURNER UNIT
A deluxe, down-draft, steel, steam or hot water heating boiler of unique design, equipped with its oil burner, all beautifully finished to give discriminating owners not only ah efficient but handsome unit. The design of boiler gives a maximum of heating surface resulting in almost complete heat transfer. Gar Wood external indirect water heaters are available for both Model R and J boilers, to provide year round domestic hot water.
Ratings and Dimensions Maximum Net Steam Load, Square Feet................ Maximum Net Hot Water Load, Square Feet.... Maximum Gross Steam Load, Square Feet............ Maximum Gross Hot Water Load, Square Feet... Heating Surface. Square Feet....................................... Overall Width, Inches...................................................... Overall Length, Inches....................................................
No. 5 500 800 750 1200 72 31% 425/,
No. 8 800 1280 1200 1920 105 3l'/2 50% -
No. 12 1200 . 1800 1800 2880 152 31% 603/4
No. 16 1600 2400 2400 3840 199 31% 71%
No. 16-35 2800 4480 4200 6720 199 31% 71%
INDIRECT AIR CONDITIONING CABINET
Combined with "R" or "J" boilers, it provides heating, humidifying, filtering and circulation of air.
The air drawn by blower, is first cleaned by dry cloth filters, then forced through the humidifying chamber, where proper amount.of ^healthful moisture is added by passing through a warm vapor mist, regulated by. a room humidistat. The air is then warmed to correct tempera ture by passage through the copper blast heater. Standard units, in capacities from--
111,000--497,000 Btu Hour at bonnet 89,000--397,000 Btu Hour at grilles
837