Document x1k13xmq3rZMop7yz4ZD8K48g
Fans and Ventilating Equipment
L. J. Wing Mfg. Go.
Branch Offices in Principal Cities
663 Hudson St., NEW YORK Phone: Chelsea 0027-0030
Factory: NEWARK., N. J.
Manufacturers of Wing Featherweight Unit Heaters, Wing Turbine and Motor Driven Blowers, Wing-Scruplex Fans and Exhausters
WING FEATHERWEIGHT UNIT HEATERS
The Wing Featherweight Unit Heater, expressly designed for overhead
installation, makes available for any industrial building a heating system that
leaves all floor and'wall space absolutely unobstructed. The success of this
system has been proven by the satisfactory operation of several hundred units
in industrial buildings of every kind and description.
The installation of Wing Featherweight Unit Heaters is extremely simple,
due to their light weight and small dimensions. For instance, a unit equal in
heating effect to 12,000 sq. ft. of direct radiation, weighs only 332 pounds.
A few advantages attending the installation of Wing Featherweight Unit
Heaters may be briefly summarized as follows:
.
The heated air from the units, located at or near the ceiling or roof, is
delivered directly downward toward the floor, heating the working level first.
Chilled areas, caused by opening of doors, are almost instantly brought back
to normal temperature by this downward method of heating.
Since the air recirculated by the heaters is taken from the upper spaces and
delivered to the lower levels, it is evident that an active circulation of air from
the ceiling to the floor is continuously maintained and that, therefore, excessive
heat is not allowed to accumulate in the upper spaces, as is the case with any
system of heating that allows the heat to rise to the ceiling immediately, as it
does in the case of direct radiation.
.
The steam and return lines are carried entirely overhead, eliminating costly
pipe trenches which are necessary when radiation is placed at or near the floor.
All vertical type heaters are furnished with ball bearing motors that do not
require attention more than once a heating season.
METHODS OF INSTALLATION
The cuts show three different methods of installation, the units in each case being located well above the head line, out of the way. The third illustration shows the high ceiling type heater installed thirty feet from the floor above a traveling crane. The column of heated air leaves the heater with sufficient velocity to strike the floor with considerable force from this point, but by. the aid of adjustable diffusers the column is divided and directed so that no objec tionable velocity is felt at the head line. The best and most economical installation of Wing Featherweight Unit Heaters is when they are placed
close to the roof or ceiling.
Low Ceiling Type High Ceiling Type
zmqEnd 6
.HZK ZEES a
`I ^ n
|
Condensed Table of Engineering Data
Unit "AxA" B Size in. in.
c
in.
D in.
Air ci.m.
Motor hp.
Temperature Room Leaving
B.t.u. per Hr.-
Available
Approx.
Shipping Weight
Lbs.
13-4-12 19% 25 75
6 1150 % 60 110 69.500 185
17-3-12 22% 27% 27% 6 1950 H 60 110 96,900 212
22-3-12 27% 27% 27% 6 3200 W 60 112 162,000 270
22-4-12 27% 77% 27*/, 6 2800 M 60 122 169,000 280
22-5-12 27% 27% 27% 6 2600 34 60 133 180,000 288
25-4-12 32% 28V, 28V, 7 4800 % 60
122 289,500
320
25-5-12 32% 28% 28V, 7 4500 % 60 133 311,400 332
30-4-85 40% 37% 37% 8 6900 l
60 122 416,000 360
30-5-85 40% 37% 37V, 8 6500 1
60 133 450,000 365
36-4-85 46% w 39% 8 9600 2
60 122 579,000 504
36-5-85 46% 39'/, 39% 8 9000 2
60 133 623,000 528
Space does not permit complete table for other room temperatures but this data will be gladly furnished on application.
410
Medium Ceiling Type Horizontal Type
L. J. Wing Mfg. Co.
Fans and Ventilating Equipment
[ie"tA*W-MGcuisa#fioMCOotNoTidAmCCiTQWWMiiosnMfcImfcoMr pUwoMiertfxtJl
WING-SCRUPLEX EXHAUSTERS
Wing Scruplex Exhausters consist of the highly
efficient "screw propeller" fan and cased in appro
priate manner with a motor on the outside where it
is clean, cool and easy of access. They are used in
duct work where the resistance is low and being de signed in the form of an elbow fit snugly in any
ii
Wing-Scruplex Exhauster
line. The accompanying diagrams show the methods of installation.
Proper SelectiorTof Exhausters--Where par ticularly quiet operation is de
sired, as in offices, residences,
hospital wards, churches theatres, etc., use lowest
speeds in all sizes. For toilet
rooms, laboratories, motion
picture booths, stock-rooms, etc., use any speed in sizes 1
and2;lowand mediumspeeds
"Wing-Scruplex " Exhausters
in all other sizes. In indus trial plants, hotel
and restaurant
Size
Inlet Sq. In. Outlet Round,
jj -ce.
Free Air
Cu. f. m.
Hp.
.15 in.
Cu. f. m.
Hp.
.25 in.
Cu. f. m.
Hp.
.40 in.
Cu. f. m.
Hp.
.50 in.
Cu. (. m.
HP.
kitchens, enginerooms, workshops, etc., use any speeds.
1-A 2-A 2-B
3-S 3-A 3-C
1ft 13% 13% 16%
W/. 16V,
10% 14% 1434 17%
17% 17%
1750 1150 1750 850 1150 1750
850 0.052 1440 0.060
2050 0.195
2130 0.090 2700 0.180
4000 0.600
630 0.054 330 0.060 950 0.069 395 0.090 1895 0.208 1695 0.216 1155 0.248 1250 0.110 2150 0.195 1550 0.221
3720 0.635 3510 0.655 3150 0.700
750 0.285 2810 0.720
The accompanying table gives perform
ances at static presures up to M in. Com plete table up to 1 in. static on request.
4-S ?1 21% 850 2850 0.100 2200 0.125 1610 0.150
4-A 21 21V, 1150 3575 0.170 3150 0.200 2775 0.220 1950 0.245 1550 0.280
4-C 21 21% 1750 5400 0.540 5160 0.600 4990 0.650 4670 0.710 4440 0.750
5-A 25 25 1150 5200 0.330 4720 0.380 4250 0.440 won 0.530 2610 0.600
5-B 25 25 1/50 8000 1.330 7740 1.360 7540 1.400 7175 1.480 6900 1.540
6-A 30 30 600 5500 0.210 3725 0.250 2375 0.330
6-B 30 30 850 7400 0.550 6280 0.600 5450 0.740 4000 6.830 3400 0.960
6-C 30 30 1150 10250 1.500 9520 1.550 8950 1.570 8000 1.620 7340 1.760
WING-SCRUPLEX FANS
Wing Scruplex Fans are built in the following sizes: 10 in., 13 in., 17 in., 22 in., 25 in., 30 in., 36 in., 42 in., 54 in., and 60 in. Capacities from 950 C. F. M. to 33,000 C. F. M. Up to 25 in. diameter, propellers are made of cast aluminum alloy while the larger sizes are of pressed steel.
Wing-Scruplex Fan
WING TYPE E M MOTOR DRIVEN BLOWER
Wing motor-driven Blowers are installed in heating boilers so that
low cost Buckwheat coal can be burned with great savings in fuel bills
and with better heating results. They are also used in industrial
plants where motor drive is preferred to turbine drive.
The'Wing E M Blower is a simple compact unit of motor, fan, and
casing, of the same general design as the Wing Turbine Blower, the
first individual forced draft fan blower ever built Where Wing units
cannot be set directly into the brick base of the boiler, they are equipped
with feet or base and mounted to the floor with the discharge connected
to the ashpit by a short sheet metal duct.
Motors are fully enclosed and
Ask for Bulletin 36
dustproof. Because of this feature
they stand up for years in the dusty
atmosphere of boiler rooms without
repair. Another feature of prime im
portance is variable speed control;
this permits of regulation without the
use of dampers and saves power.
Wing Blowers are cutting down
fuel bills in hundreds of schools,
apartment houses, lofts, hotels,
churches and institutions throughout "
the country. Booklet 36 describes
Wing motor-driven units.
Information on Wing turbine-
TyPe E M Blower
driven units in Bulletin 77.
Typical installation in a New York, apartment house where the use ofBuckwheat
coal in place of domestic sizes is satring the owner a large part of his previous fuel bill.
In the right foreground is shown an E M Blower connecting directly into the rear end of a cast-iron hot water boiler; the
E M Blower in the background serves the two steam heating boilers. Note how com
pact this installation is--a characteristic of Wing E M Blower layouts.
411