Document x1dyaN41ZaD4OVMBmEda999G1

Heating Ventilating Air Conditioning Guide 1955 Vapor, vapors (continued) pressure. 7 transfer. 202 Warm air {continued) extended plenum, 465 furnace capacity, 406 Water (continued) services, 1095 storage capacity, 1105 transmission, 202 installation practice, 455,456 supply piping, 1112 unit heater connection. 593 Vaporizing oil burner, 371 standardized combinations, 458 arrangement, 1113 temperature control, 1113 Velocity, 10 capture, 1032 coil, 607,613,833 conveying, 1034-1038 duct, 738, 1034 exhaust intakes, 716, 1032, 1034-1038 hood. 1031 operating, 738, 770, 1032, 1034- 1038 mechanical heating systems,-- 467 air distribution. 467 automatic control, 409. 482. 895 ceiling panel system, 4S2 combination of parts. 470 cooling methods. 677 continuous circulation, 482 dampers, 469 design procedure, 464, 473 thermodynamic properties of, 40 treating chemicals, 971, 992 well temperatures, 802 Water vapor, 25*32-40. 199 condensation in buildings, 199 saturation pressure, 25, 40 specific enthalpy, 4 specific volume, 10, 40 surface, condensation. 211 pressure, 7 reduction method, 739- ducts, 469 fans, 404 Welding. 617 .k return,grilles, 716 unit- heater, 587 Ventilation, 10, 272 animal shelters, 236-240 filtera. 404 furnace, 403 heavy duty, 404 selection, 463, 476 humidification, 409 Wet-bulb temperature (see Temperature), 9, 26, 813 Wet cup, 207 Wet return, 8,486 dairy stables, 237 large systems, 473 garages, 240 living apace, 217, 272 perimeter system, 483 pressure drop, 481 Wind, winds forces, 222, 229 natural, 229 general rules, 235 registers and grilles, 468 standard combinations, 458, due to stack effect, 222 natural draft equipment, 807 passenger bus in summer, 1084 railway passenger car, 1081 470 panel heating, 482 selection of, velocity, 244, 245, 272 rules, 235 radiators, 381 ship, 1089 symbols for drawings, 17 systems, 677 walls and attics, 218 wind forces, 230 Washer, washers. 797 air, 1,797 cooling, 801 dehumidification, 801 Window, windows - coefficients of transmission, 195 leakage, 223 solar radiation through. 291 Ventilator, ventilators. 234 control, 235 roof, 234 unit, 596 control, 600, 903 window, 601 Vertical blow unit beater, 587 Vertical openings, 228 sealing of, 228 Vibration, machine, 949 Viscous filters, 777 impingement, 777 Vitiation of air. 111 Volume control, 715 furnace, 368, 375 specific, 10 humidification, 799 Water analysis, 972 atmospheric cooling equip ment. 805,807 characteristics, 972 classification, 972 coils, 826, 1111 content of radiators, 542 control temperature service, 1113 cooled condenser, 872 cooling tower, 807 corrosion treatment, 987 demand, 1096.1106-1108 faucets, 1096 fittings, loss, 1096,1101 ventilators, 601 Winter air conditioning system, 677, 1119 comfort zone, 124 freezing equipment, 822 Wound rotor motor, 918 Wrought-iron pipe, 617 Wrought-steel pipe, 617 Y Year-round air conditioning system, 677, 1119 ' air flow in, 678, 1123 control methods, 678, 905 design procedure, 690 equipment arrangement, 678- 680 w`i 3 fixtures, 1096 fixture units, 1096 installation, 678 location of apparatus, 689,1122 i \ Wall.twalls heat flow through, 185-188,282 formed deposits, 971 heater coal-fired, 1108 selection, 687, 1119 zp i | j! beat transfer coefficients, 89, 186-188 infiltration through, 222 time lag of solar radiation, 304 solar, 1115 heating, 1108 in building material, 201 load, 1095 Zone control. 678 Zone of evaporative regulation, 115 ! Warm air make-up, 821, 980 r gravity heating system, 455 combination carrying ca- maximum main temperature, 800 Zoning, 544, 678 control, 678, 910 \ parity, 461, 462 meters, 1101 hot water system, 544 ; design procedure, 457, 461, mineralized, 972 reheat, 678 i . 465 properties of, 40, 972 volume control, 679 XXIV *1 CHAPTER 1 TERMINOLOGY Glossary of Physical and Heating, Ventilating, Refrigerating and Air Conditioning Terms Used in the Text Absolute Zero: The zero from which absolute temperature is reckoned. Ap proximately --273.2 C or --459.8 F. Absorbent: A sorbent which changes physically or chemically, or both, during the sorption process. Absorption: The action of a material in extracting one or more substances present in an atmosphere or mixture of gases or liquids; accompanied by physical change, chemical change, or both, of the sorbent. Acceleration: The time rate of change of velocity, t.e., the derivative of velocity with respect to time. In the cgs system the unit of acceleration is the centimeter per (second) (second); in the fps system the unit is the foot per (second) (second),a = ^. Acceleration Due to Gravity: The rate of gain in velocity of a freely falling body,. the value of which varies with latitude and elevation. The international gravity standard has the value of 980.665 cm per (sec) (sec) or 32.174 ft per (sec) (sec) which is the actual value of this acceleration at sea level and about 45 deg latitude. Adiabatic: An adjective descriptive of a process such that no heat is added to, or> taken from, a substance or system undergoing the process. Adsorbent: A sorbent which does not change physically or chemically during the sorption process! Adsorption: The action, associated with surface adherence, of a material in ex tracting one or more substances present in an atmosphere or mixture of gases and liquids, unaccompanied by physical or chemical change. Commercial adsorbent materials have enormous internal surfaces. Aerosol: An assemblage of small particles, solid or liquid, suspended in air. The diameters of the particles may vary from 100 microns down to 0.01 micron or less,e.g., dust, fog, smoke. Air Cleaner: A device designed for the purpose of removi ng airborne impurities such as dusts, gases, vapors, fumes and smokes. (Air cleaners include air washers, air filters, electrostatic precipitators and charcoal filters.) Air Conditioning: The simultaneous control of all, or at least the' first three, of "the following factors affecting both the physical and chemical conditions of the at mosphere within a structure: temperature, humidity, motion, distribution, pressure, dust, bacteria, odors, toxic gases, and ionization. Air, Dry: In psychrometry, air unmixed with, or containing no, water vapor. Air, Saturated: A mixture of dry air and saturated water vapor, all at the same dry-bulb temperature. Air, Standard: Air with a density of 0.075 lb per cu ft and .an absolute viscosity of 1.22 X 10-5 lb mass per (ft) (sec). This is substantially equivalent to dry air at 70 F and 29.92 in. (Hg) barometer. Air Washer: An enclosure in which air is drawn or forced through a spray of water in order to cleanse, humidify, or dehumidify the air. Anemometer: An instrument for measuring the velocity of a fluid. Aspect Itatio: In air distribution outlets, the ratio of the length of the core of a grille, face or register to the width. In rectangular ducts, the ratio of the width to the depth. Atmospheric Pressure: The pressure due to the weight of the atmosphere. It is the pressure indicated by a barometer. Standard A tmospheric Pressure or Standard Atmosphere is the pressure of 76 cm of mercury having a density of 13.5951 grams per cu cm, under standard gravity of 980.665 cm per (sec) (sec). It is equivalent to 14.696 lb psi or 29.921 in. of mercury at 32 F. Baffle: A surface used for deflecting fluids, usually in the form of a plate or wall. 1