454 CHAPTER 19 1952 Guide ~ Table 3. Capacity Tables fob Warm Aik and Return Air Branches*' b FIRST STORY For UNINSUL- Mettal Ducts Actual Length (from Bonnet to Boot) or, (from Return *lenum to Boot) in Feet 1 to 7 FT. 8 to 12 13 to 17 18 to 24 25 to 34 35 to 44 45 to 54 FT. FT. FT. FT. FT. FT. Col. a Col. b Col. c Col. d Col. e Col. f Col. g Warm Air Combi- NATION No. Air . Combi- nation No. Section A. 7200 12500 40 to 69 16000 Equivalent. 19100. Ft for Fit tings and 25000 Register 32000 80000 6700 11700 15000 18000 6100 10800 14000 17000 23400. 21600 30000 28000 75000 70000 5600 9900 13000 16000 19800 26000 65000 4800 8500 11300 14200 17000 22600 56500 4100 7400 9900 12500 14800 19800 49500 3500 6400 8700 11000 12800 17400 43500 Section B. 70 to 99 Equivalent Feet 5500 9900 13100 16300 19800 26200 65500 5100 9200 12300 15400 18400 24600 61500 4800 8600 11600 14500 17200 23200 58000 4500 8100 10900 13700 16200 21800 54500 3900 7100 9700 12200 14200 19400 48500 3400 6200 8500 10800 12400 17000 42500 3000 5400 7500 9500 10800 15000 37500 41 42 43 44 45* 46* - ----- 41 42 43 44 45* 46* -- 51 52 53 54 55 56 57* 51 52 53 54 55 56 57 Section C. 4600 8500 100 to 129 11300 Equivalent 14300 Feet 17000 22600 .56200 4300 7900 10600 13500 15800 21200 52600 4100 7400 10000 12700 14800 20000 50200 3800 6900 9400 11900 13800 18800 47300 3300 6100 8400 10500 12200 16800 42000 3000 5300 7400 9300 10600 14800 37000 2700 4700 6500 8300 9400 13000 32400 Section D. 130 to 164 Equivalent Feet 4100 7300 9800 12300 14600 .19600 49200 3800 6900 9100 11700 13800 18200 45800 3600 6400 8600 11000 12800 17200 41900 3400 6000 8100 10300 12000 16200 40300 2900 5300 7200 9100 10600 14400 36000 2600 4700 6400 8100 9600 12800 31800 2300 4200 5600 7100 8400 11200 28100 Section E. 165 to 200 Equivalent Feet , 3800 6500 8800 11000 13000 17600 44100 3500 6100 8200 10500 12200 16400 41500 3300 5700 7700 9900 3100 5400 7200 9300 11400 10800 15400 14400 38800 ,36000 2700 4800 .6400 8300 9600 12800 32000 2400 4300 5700 7300 8600 11400 28200 2100 3800 5000 6400 7600 10000 24700 41 42 43 44 45* 46* -- 41 42 43 44 .45* 46* ;-- " 41 42 43 44 45* 46* -- 51 52 53 54 55 56 57* 51 52 53 54 55 56 $7* 51 52 53 54 55 56 57* Fob INSULATED Ductb Col. a 1 TO 9 Col. b 10 TO Col. c . Col. d 18 TO 24 FT. 25 to Col. e 35 to COMFor Ducts that are PLETELY INSULATED with i In. Thick Insul ation from Bonnet to Boot, use these Column Headings. * These tables are for use in sizing both the warm air and the return air branches. b Frictional resistances and temperature drops in ducts have both been accounted for in these tables. c Use these, items only when the building construction, or capacity requirements, necessitate the use of two adjoining stacks or floor registers. Forced Warm Air Systems 455 Table 4. Capacity Tables for Warm Air and Return Air Branches** *> SECOND STORY For UNINSU LATED Metal Ducts Actual Length (from Bonnet to Boot) or, (from Return Plenum to Boot) in Feet 1 to 7 FT. 8 to 12 FT. 13 to 17 18 TO 24 25 to 34 35 to 44 45 to 54 FT. FT. FT. FT. FT. Col. a Col. b Col. c Col. d Col. e Col. f aCol. WXrm Air . Combi- . NATION No. Return Air Combi- nation No. Section A. 40 to 69 Equivalent Ft for Fittings and Register 6300 10900 14000 17000 21800 28000 70000 5700 10000 13000 15900 20000 26000 65000 5200 9200 12100 14900 18400 24200 60500 4800 8500 11400 13900 17000 22400 57000 4100 7300 10000 12400 14600 20000 50000 3500 6400 8800 11100 12800 17600 44000 3100 5600 7800 9900 11200 15600 39000 41 51 42 '52 43 53 44 54 45* . 55 46' 56 57' Section B. 70 to 99 Equivalent Feet 5000 .9000 11900 14800 18000 23900 59500 . 4600 8200 11000 13900 16400 22000 55000 4300 7600 10300 13000 4000 7100 9600 12200 15200, 14200 20600 19200 51500 48000 3400 6200 8400 10800 12400 16800 42000 3000 5400 7500 9600 10800 15000 37500 2700' 4700 6700 8500 9400 13400 33500 -41 51 42 52 43 53 44 54 45' 55 46' 56 -- ; - 57' Section C. 100 to 129 Equivalent . Feet 4200 7700 10400 13000 15400 21700 52200 390) 7200 9700 12100 14400 19400 48400 3700 6700 9000 11300 13400 18000 45300 3500 6200 8400 10600 12400 16800 42300 3000 5400 7400 9400 2600, 4700 6500 8300 10800 9400 14800 13000 37000. 32500 2400 4100 5800 7400 8200 11600 29000 41 42 4344 45" 46' -- 51 52 53 54 55 56 57' Section D. 130 to 164 Equivalent Feet 3800 6800 9100 11400 13600 18200 45500 3500 6300 8400 10500 3200 5800 7900 9800 12600- 11600 16800 15800 42000 39600 3000 5500 7400 9200 11000 14800 36800 2700 2300 4800. 4200 6300 5700 8100 7200 9600 8400 12600 11400 32200 28200 2100 3700 5000 6400 7400 10800 25100 41 42 43 44 45* 46' --* ' 51 52 53 54 55 56 57' Section E. 165 to 200 Equivalent Feet 3500 6100 8200 10300 12200 16400 41000 3200 5700 7600 9500 11400 15200 38300 2900 5300 7100 8900 10600 14200 35800 2700 5000 6700 8300 10000 13400 33400 2500 4400 5700 7400 8800 11400 29000 2100 3900 5100 6500 7800 10200 25800 1900 3400 4500 5800 6800 9000 22800 41 42 . 43 44 45' 46' -- 51 52 53 54 55 56 57' ' Fob INSULATED Ducts Col. a 1 to 8 FT. Col. b- 9 to 14 FT. Col. c 15 to 20 FT. Col. d - Col. e 21 to 27 28 to 42 FT. Col. f 43 to 54 FT. COMFor Ducts that *bb PLETELY INSULATED with | In. Thick Insulation from Bonnet to Boot Use these Column Headings. * These tables are for use in sizing both the warm air and the return air branches. b Frictional resistance and temperature drops in ducts have both been accounted for in these tables. c Use these items only when the building construction, or capacity requirements, necessitate the use of two adjoining stacks or floor registers. ..