Document x1LyvYmkQxBndQOk0kVKanm00

296 CHAPTER 13 1957 Guide- tion of heat to the enclosure by any one or all of the mechanisms of conduc tion. convection, and radiation. A gain of latent heat is considered to occur when there is an addition of water vapor to the air of the enclosure. For example, when the humidity in an enclosure is increased by water vapor emitted by human occupants, or by water vapor resulting from a process such as cooking, the heat required to vaporize the water does not come from the air. Maintenance of a constant humidity ratio in a sealed enclosure requires the condensation of water vapor in the cooling apparatus at a rate equal to its rate of addition within the enclosure. The rate of heat removal from this condensing vapor would be substantially equal to the product of the rate of condensation and the latent heat of condensation; this product, expressed in Btu per hour, would be called a latent heat load. As a further example, the infiltration of outdoor air with a high drybulb temperature and a high humidity ratio, and the corresponding escape of room air at a lower dry-bulb temperature and a lower humidity ratio, would increase both the sensible heat load and the latent heat load. SOLAR RADIATION Magnitude of Solar Radiation If a plane surface were set perpendicular to the sun's rays (i.e., for normal incidence) outside the earth's atmosphere, it would receive solar radiation of about 420 Btu per (hr) (sq ft). A similarly oriented surface, at the surface of the earth, would receive considerably less solar energy because a large part of the radiation is scattered in passing through the air, moisture, smoke, and dust which comprise the earth's atmosphere, and alsp, because some of the atmospheric constituents, notably water vapor, ozone, and carbon dioxide, absorb solar radiation. . The intensity of solar radiation varies with wave length, reaching a peak at about 0.5 microns (a micron equals 1/1000 of a millimeter) and, for practical pur poses, is confined to the radiation spectrum between 0.3 and 2.3 microns. The effects of scattering and absorption vary with the wave length, but to make an exact analysis of these phenomena is impracticable in airconditioning estimates. The important principle to remember is that the total radiation 11, received by a surface at the earth, is the sum of In and Id, where Id = K Id, = the direct or beamed solar radiation, Btu per (hour) (square foot of receiving surface). Id, = the direct solar radiation on a plane normal to the sun's rays, Btu per (hour) (square foot of receiving surface). Id = the sky or diffuse solar radiation, Btu per (hour) (square foot of receiving surface). This comes principally from the atmosphere itself as a conse quence of scattering. Vertical surfaces also receive solar radiation by reflection of direct and diffuse radiation from the ground and other objects. Such radiation is usually diffuse. The diffuse radiation strikes at oil angles. It = total incident solar radiation, Btu per (hour) (square foot of receiving : surface). K = cosine of the angle of incidence, 0. For a vertical surface, 6 is defined is Fig-1. ' Standardized, practical-purpose values of the direct solar radiation Ido incident upon a plane perpendicular to the sun's rays at the earth's surface; Cooling Load 297 Fig. 1. Definition of Solar Angles have been proposed by Moon.' Table 4 gives these values. They are representative of a dear summer day at sea-level elevation, and are nearly identical with values derived from suggested design sol-air temperatures for Lincoln, Nebraska.6 Values typical of a humid industrial area derived from sol-air data for New York City* are also given in Table 4. Day-today changes in the amount of, dust and water vapor in the atmosphere cause large differences in solar intensity values observed on cloudless days at a given locality. For example, it has been observed in Cleveland that Table 3. Outdoor Air Requirements Application Smoking Cfm per Person1* Cpmpbb SQb Ft or Floor Apartment Average. n i ,, DeLuxe. "udung Space.......... Barber Shore... Beauty Parlors. Some.............. Some.............. Occasional___ Considerable.. Occasional...... Recommended Minimum* 20 10 20 10 170* 15 10 10 n Minimum4 Very Heavy.. 50 40 20 25 Directors' Booms ........... fDftrtutogriSetsodre. st* Five and Ten Cent Stores.................... Funeral Parlors....................................... Garages........................................................ Considerable.. None_____ None.................. None.................. b Operating Booms** *. Private Rooms.. Hotel BooWmsa.r.d..s.................................... Kitchens Restaurant......... None... None... None... Heavy. LaboratoriRees*s.i.d..e..n..c..e.................................................................... Some.. Meeting Rooms Offi.ce* General Very Heavy Private. Some............ RestauPrarnivtaCteaf..e..t.e..r.i.a..4.................. None............ Considerable___ Dining Room4 School Rooms*1.................... Considerable___ Considerable. TSThhheeoapat,teeRrr.e..t..a...i.l........................................................ Toilet^ (Exhaust).............. None.. None.. None... Some... n 50 10 10 7* 10 30 20 30 50 25 25 30 12 15 10 7* 15 5 30 I 7* 25 10 25 10 15 25 10 12 7i 5 10 0.25 0.05 1.0 2.0 0.33 0.33 4.0 2.0 .1.25 0.25 0.25 2.0 "FSjjppeceialcJ.iVa?-PPiM^?Bee,lto"dcaaa,lylecooPddreaeesctw_ic_h_ei.chbmT_a^hyissgoisvceornn.tam4iMnaanyt-bfreegeoavierr.need.Wbyheenxmhaiunsimt. um` Misayusbeed,gtoavkeerntheed hazard contamination or local codes. * All outside air recommended to overcome explosion *0esthetics. See National Board 4/Fire UndorviriUrt' pamphlet No. 56.