Document x1LZjoGkJ1KXxe33592bEnM5J
NATIONAL CONFERENCE ON
POLYCHLORINATED BIPHENYLS
JAMES P. MIEURE CHARACTERIZATION OF POLYCHLORINATED BIPHENYLS
November 19 - 21, 1975 Pick - Congress Hotel Chicago, Illinois
Monsanto
MONS 045149
CHARACTERIZATION OF POLYCHLORINATED BIPHENYLS
J. P. Mleure, 0. Hicks, R. G. Kaley and V. W. Saeger Monsanto Company 800 N. Lindbergh Blvd. St. Louis, Missouri 63166
CHEMICAL STRUCTURE Polychlorinated biphenyls (PCBs) are made by direct chlorination of biphenyl. The biphenyl molecule has ten possible sites at which chlorine atoms can be substituted. The numbering system for the biphenyl structure is shown In Figure 1. By convention, the two rings are numbered identically except the ring with the fewest chlorine substituents or substituted in the highest numerical positions Is designated as primed. Examples of nomenclature for a trl- and a tetrachloroblphenyl are included In Figure 1. An excellent discussion of PCB nomenclature can be found In a recent text by Hutzinger, Safe and Zltko (1).
There are 209 possible chlorobiphenyl Isomers distributed as Indicated in Table I. However, many of these Isomers are not likely to occur at significant levels In commercial PCB mixtures. For example, Isomers with four or five chlorine atoms on one ring but none on the other ring are not detectable In PCB products.
MONS 045150
-2-
TABLE I
209 POSSIBLE PCB ISOMERS
Degree of Substitution
Number of Isomers
Mono D1 Trl Tetra Penta Hexa Hepta Octa Nona Deca
3 12 24 42 46 42 24 12
3 1
209
AROCLOR PRODUCTS
The major producer of PCBs In the United States Is Monsanto Company,
which markets mixtures for closed electrical system applications
under the Aroclor trademark. Aroclor products are Identified by a
four digit numbering code In which the first two digits, 12, Indicate
the parent molecule Is biphenyl and the last two digits specify the
weight percent of chlorine. The exception Is Monsanto's newest
product, Aroclor 1016 (41% chlorine), which retained the 1016
designation by which It was known during development. Aroclor
products manufactured In the United States are listed In Table II.
Production of the materials listed as discontinued was terminated In
or prior to 1971.
HONS 045151
-3-
TABLE II
AROCLOR PRODUCTS MANUFACTURED IN THE U.S.
Current
Discontinued
Percent Chlorine
1221
1016 1242
1254
1232
1248
1260 1262 1268
21 32 41 42 48 54 60 62 68
AROCLOR COMPOSITION
.
The composition of the four Aroclor products currently marketed In
the United States Is given In Table III. Aroclor 1221 Is primarily
monochloroblphenyl while Aroclor 1016 and Aroclor 1242 are primarily
trlchloroblphenyls. The major difference between these two products
Is the lower penta- and hexachloroblphenyl content of Aroclor 1016.
Aroclor 1254 Is primarily pentachloroblphenyl. The values In Table III
were calculated from measurements by gas chromatography with flame
Ionization detection after component Identification by gas chromatography/
mass spectrometry. All gas chromatographic separations were made
with a high resolution capillary column. Average response factors
determined for each degree of chlorine substitution were applied to
all components.
*ONS 045152
-4-
TABLE III
TYPICAL PERCENT COMPOSITION OF AROCLOR PRODUCTS
HOMOLOG
f Cl/BIPHENYL
0 1' 2 3 4 5 6 7 8
AROCLOR 1221
11 51 32
4 2 <0.5 ND ND ND
AROCLOR 1016
<0.1 1
20 57 21
1 <0.1 ND ND
AROCLOR 1242
<0.1 1
16 49 25
8 1 <0.1 ND
AROCLOR 1254
<0.1 <0.1 <0.5
1 21 48 23
6 ND
ND - NONE DETECTED. <0.01*
Detailed chromatograms of these four products are Illustrated In Figures 2-5. Specific Isomer Identifications determined by Webb and McCall (2) and Sissons and Welti (3) are listed for the major Arodor 1242 components In Figure 4. The complexity of these mixtures was emphasized by amplifying the first and last portions of the Arodor 1254 chromatogram In Figure 5. Eighty-five components were detected In Arodor 1254. A ,32 mm Id X 50 m glass capillary column coated with 0V-101 was used for these separations. The flow rate was 2 ml/min helium and the column temperature was programmed from 150 to 230C at 2C/m1n.
MONS 045153
-5-
Hlgh resolution chromatographic conditions are very useful for characterizing PCB products. However, for routine monitoring of environmental materials, It Is more appropriate to use gas chromatog raphy with packed columns and electron capture detection. Typical
chromatograms of this type for Aroclor 1016 and Aroclor 1242 are compared In Figure 6. The chromatograms are essentially Identical for retention times less than 70 relative to p,p'-DDE. However, the higher chlorinated components with relative retention times 70 and greater represent a significantly smaller contribution In the Aroclor 1016 chromatogram.' These chromatograms Illustrate the feasibility of distinguishing these unaltered products. However, In environmental materials the characteristic features of Aroclor 1242 are frequently obscured by interfering compounds or by component alteration so the distinction Is less clear or sometimes entirely lacking. These separations were carried out on a 6 ft. X 4 mm Id glass column packed with 3X SE-30 on 80/100 mesh Chromosorb W - HP at 190*C.
PHYSICO-CHEMICAL DIFFERENCES
The physical and chemical properties of PCB Isomers and comnerclal
mixtures vary greatly depending on the degree and position of chlorine
substitution. The effect of chlorine content on several physico-chemical
properties Is summarized In Table IV. Three of these properties,
volatility, water solubility,and blodegradablllty, are very relevant
to the environmental occurrence of PCBs. Volatility and water solubility
represent potential mechanisms for Introduction Into and transport
within the ecosystem. Biodegradation represents a mechanism for
removing PCBs from the environment. Illustrations of the relative
significance of these properties for different PCB Isomers are evident
from the following three examples.
MQNS 0V5154
W- l.
-6-
TABLE IV PHYSICO-CHEMICAL PROPERTIES FOR PCB PRODUCTS
Density (g/ml)
Property
Percent Chlorine 21 42 64
1.19
1.39
1.50
Distillation Range (C)
275-320
325-366
365-390
Fire Point (C)
176 None None
Vaporization Rate (mg/cmVhr eiOO'C)
1.74
.338
.053
Water Solubility (ppm)
>.2
.2
.04
Blodegradabllity*
81 26
15
Percent degradation/48 hr cycle with semi-continuous activated sludge
Relative volatilities for the PCB components In Aroclor 1016 are Indicated in Figure 7 by comparing chromatoarams of liquid and vapor composition. The higher numbered components make successively less contribution to the total vapor composition.
Water solubility of Aroclor 1016 components Is Illustrated in similar
fashion In Figure 8. Water saturated with Aroclor 1016 was extracted
with hexane and the extract compared chromatographlcally to an Aroclor
1016 standard. The numbers above significant peaks express the
percentage contribution of that peak area to the total area. Earlier
eluting, lower chlorinated components are more soluble and contribute
more to the water saturated composition. A related study has shown that
PCBs leaching from Aroclor 1016 Impregnated soils after the equivalent
of forty years annual rainfall consist of lower chlorinated biphenyls (4)
(Figure 9).
HONS 045155
-7-
Mlcroblal degradation also affects PCB Isomers to different degrees. For example. Figure 10 shows chromatograms depicting Aroclor 1016
composition after exposure to a naturally occurlng mixed microbial population for 1/2 hour (above) and 14 days (below). The number above
each GC peak Indicates the percent biodegradation for that component.
These percentages range from 17 to >98 and In general are higher for
lower chloroblphenyls. The exposure-was carried out with activated
sludge from a domestic sewage treatment facility. The sludge was
previously acclimated to a mixture of Industrial organic compounds
before addition of 3 ppm Aroclor 1016. PCB composition was determined
by extracting a representative aliquot of mixed liquor with hexane
followed by analysis by gas chromatography using a glass capillary
column and electron capture detection.
-
It Is apparent from these examples that Introduction of PCBs Into the ecosystem by volatility or water solubility would enhance the ratio of lower to higher chlorinated biphenyls in the environment. PCB removal from the environment by either of these mechanisms or by microbial degradation would reduce this ratio. These and related factors combine to make assessment of PCB environmental impact a very complex problem.
In view of the recognized complexity In studying commercial PCB mixtures. It would seem expedient to substitute for the mixture a single Isomer product having the desired electrical and physical properties. The environmental properties of this isomer would be much simpler to
HONS 045156
-8-
characterlze and control. However, no such PCB Isomer exists. Most PCB Isomers are solid crystalline materials when Isolated at 25C. Commercial products are liquids only because of the mutual melting point depression exerted by the PCB components of the mixture. CONCLUSIONS Commercial PCB products are mixtures of many different Isomers with varying chlorine content. The properties of these Isomers, and hence the products, are vastly different and are complex to study. The environmental Impact for each product must be accurately assessed and compared to the functional benefit.
mqns 045157
REFERENCES 1. 0. Ilutzlnger, S. Safe and V. Zltko, "The Chemistry of PCBs",
CRC Press, Cleveland, 1974. 2. R. G. Webb and A. C. McCall, J. Assoc. Offic. Anal. Chem.,
55, 746(1972). 3. 0. Sissons and 0. Welti, J. Chromatog., 60, 15(1971).
4. E. S. Tucker, W. J. Lltschgl and W. M. Mees, Bull. Environ.
Contam. Toxicol., J3, 86(1975).
MCINS 045158
32
2' 3'
Cl Cl
Cl
HONS 0 4 5 1 5 9
2,2',3,4-TETRACHLOROBIPHENYL Figure 1
Figure 2
HONS 0 4 5 1 6 0
Figure 3
lMONS 0 4 5 1 6
AROCLOR 1242
CM CM
" in
jiJlu \Mi^
174 198 222 230
Figure 4
AROCLOR 1254
150 174 198
222 230
TEMPERATURE C
Figure 5
HONS 0 4 5 1 6 3
37
AROCLOR 1242
37
HONS 045164
Figure 6
Time (Min)
Figure 7
AROCLOR 1016
22.6
19.4 16.3 I
18.4 I
10.1
STANDARD
6.7 16.2
11.2 WATER SOLUBLE
11.3
7.3
VJ uv
Figure 8
HONS 0 4 5 1 6 6
MONS 045167
AROCLOR 1016 BIODEGRADATION
MQNS 0 4 5 1 6 8