Document x1KJg4DeVJbx3E1e1dVGZ3DDy
458
CHAPTER 17
1958 Guide
, . shall be, not less than .the area of the largest flue or vent connector, plus 50
, : per cent.of the areas of the'additional flue or vent connectors.
. ;>
3. An elliptical flue or vent may be used provided its flue gas venting!capacity is equa! to the capacity of the round pipe for which it is substituted.
- Since Fig. 10 has been prepared for circular flues, relative capacities for
rectangular and semi-elliptical flues14 are shown in Fig. 11.
' Heating appliances designed to burn gas, as well as appliances converted1 to gas'burning, except those equipped with power type burners and ex-
. Chimneys and Draft Calculations
459
relief opening is always open, and consequently some air is drawn into the chimney. This air lowers the gas temperature in the chimney, but it also lowers the dew-point of the gases and tends to prevent condensation.
The installation of conversion burner equipment in large boilers is usually made in accordance with regulations of the local gas company. In such installations a definite chimney draft may be required for proper combustion, and consequently the foregoing reference to the use of draft
hoods would not apply.
The products of complete combustion of gas are water vapor (HsO) and carbon dioxide (CO2). In the case of manufactured gas, the presence of organic sulfur compounds, generally between 3 and 15 grains per hun dred cubic feet, gives rise to minute percentages of sulfur dioxide and sulfur trioxide. The volume of water vapor in the flue products from natural or coke oven gas is about twice the volume of carbon dioxide. It is extremely
Fig. 10. Capacity in Btu per Hour for Gas Appliance Flues or Vents
cepting conversion burner installations in excess of 400,000 Btu per hour input in large steel boilers, are always equipped with a draft hood attached to the flue outlet of: the appliance. This draft hood is required if the' appliance is to meet the approval requirements of the American Gas As sociation and the American Standards Association, and is essential for safe operation. It is designed to prevent excessive chimney draft which would lower appliance efficiency, to prevent a blocked flue or a down-draft in the chimney from impairing combustion, to provide a relief opening for the products of combustion during down-draft or blocked flue conditions, and to prevent spillage of the products of combustion to the space surrounding the appliance, if there is a chimney draft equivalent to that provided by * 3-ft chimney. As the draft hood is designed without moving parts, the
Fig. 11. Capacity of a Rectangular Flue or a Semi-Elliptical Flue, with Semi-Circular Ends Having Its Minimum -Width Equal to the Diameter of a Circular Flue, Compared with the Capacity of the Circular Flue
important that the chimney be tight and resistant to corrosion, not only from moisture, but also from dilute sulfur trioxide.
Clay linings with joints which prevent retention of moisture and linings made of non-corrosive materials, are advantageous. The interior protec tion of unlined chimneys by applying an asphalt-chromate emulsion has peen investigated by some gas companies but the material is not of current
coatiifk because insurance companies do not favor potentially combustible
An investigation of damage occurring in 78,129 chimneys used for vent-
ig gas appliances in a severe climate has been made by the Minneapolis Company with the results shown in Table 4 taken from Reference 15.
y Vlc regarding recommended practice and materials for flue connecDanv an a Lmney linings can usually be obtained from the local gas com-
y, and should be given careful consideration.
RECOMMENDATIONS OF THE NATIONAL BOARD
maFdopr
OF FIRE UNDERWRITERS data on the construction of chimneys, reference should be
w the National Building Code, recommended by the National Board