182 CHAPTER 13 1962 Guide And Data Book of either the central type or individual room type, to provide summer air conditioning. TYPES OF SYSTEMS The present generally accepted method of cooling resi dences is to employ a central system. The main components of the central plant for year-round air-conditioning systems may be obtained in factory-made assemblies providing matched components for both winter and summer condition ing functions or they may be obtained in one or more separate parts and combined on the job into an integrated system. Summer conditioning equipment may be obtained separately and added to heating systems or may be installed in dependently of any heating system. Cooling coils may be ned in conjunction with warm air furnaces and duct systems, or chillers may be combined with boilers to provide hot and cold water for circulation to room units as required. Refer to Chapters 13, 34, 53, and 57 of the 1961 Guide And Data Book for information on specific system components. Self-contained room coolers, which are discussed in Chapter 56, of the 1961 Guide And Data Book, are used for room or spot cooling and are not generally used to cool an entire residence. Their application and use are not to be considered further in this chapter, but it may be noted that when only a portion of a residence is cooled the load calculation methods currently used in the industry for central residential systems are not applicable. Refer to Chapter 26 of the same volume when calculating the load for such applications. In some areas there is little or no need for heating but there is a distinct need for summer cooling. Both air- and water- cooled package cooling units are available for such areas and range in siTM from one ton to at least 15 tons capacity. To install these units it is only necessary to make plumbing (for water-cooled units) and electrical connections and add the ductwork required to convey air to and from the condi- - tiooed space. These unite can also be used to provide central air conditioning for residences having heating systems which do not contain provision for attaching summer cooling equip ment. Year-round air conditioners require less space than a sepa rate heating plant plus a separate summer conditioner. Usu ally the heating and cooling portions of a year-round air conditioner operate independently of each other. The air cir culated by the fan pases through the cooling and heating portion of the equipment, only one of which is in operation at any one time. Some systems are designed to shift the air path alternately through the cooling or the heating surfaces, but many systems use the ampler method of pasting the air over both surfaces at all times. Both systems are normally equipped with interlocking control arrangements so that only cooling or only heating will occur at any one time. Air conditioning can be installed in homes having a hot- water heating system by use of either of the following means: 1. Roam units resembling convectors and containing both beating and cooling coils. These units are used in place of the conventional radiator or convector. They can be installed In all rooms of the bouse to provide complete Summer cooling, or they can be used in only one or two rooms. This arrangement is shown in Fig. 1. 2. A split system. The cooling coil is located in a duct through which air from the rooms is circulated, cooled, and returned to the rooms. Another coil in the same duct be used for, winter heating, or conventional radiators, convectors, or panels' can be used to bring beat to the rooms. When cooling equipment producing dulled water is to be used in a house equipped with a forced-circulation hot water hftating system the chiller may be located in the basement or Fig. 1 .... Combination Summer Air-Conditioning and Hot Water Heating System utility room near the boiler. In most of such systems it is then possible, with the addition of suitable valves, to use the same piping system for circulation of heated water in winter and chilled water in summer. The piping must be insulated, to prevent sweating when circulating chilled water. GAS YEAR-ROUND AIR CONDITIONERS Gas-fired year-round air conditioners based on the ab sorption cyde are available in sizes suitable for residential use and for small commercial applications. The conditioners are built in 3Vi ton and 5 ton sizes with heating capacities appropriate for various climates. The 3Vi ton and one model of the 5 ton units have heating inputs of 120,000 Btuh. This makes them suitable for homes having design beat losses up to 76,800 Btuh. The other 5 ton model has an input of 180,000 Btuh making it suitable for homes having design heat losses up to 115,200 Btuh. General Description The principal components of the gas-fired year-round air conditioner are an absorption unit, a gas burner, a cen trifugal fan for air circulation, a filter section, and controls. The gas flame supplies the beat to actuate the absorption unit which provides heating in winter and cooling in sum mer. The entire unit operates under a vacuum at all times. The absolute pressure within the generator and condenser on cooling cyde is of the order of 2 to 2Vi in. Hg (50 to 60 mm) absolute pressure. The pressure within the cooling coil and absorber is between 0.25 to 0.3 in. Hg (6 to 9 mm) preffiure. On the beating cyde, since the same' coil is used for both heating and cooling, the absolute pressure is on the order of 14 in. Hg (350 mm) or about Vi atmosphere. Heating Cyde The gas flame, when applied to the generator of the ab sorption unit in winter, boils the solution. The water vapor which is thus produced goes directly (bypasses the con denser) to the single coil over which air is passed by the blower. The heat is taken from the water vapor, and the wa ter is returned to the generator by gravity to be used again- Cooling Cyde The gas flame, when applied to the generator of the ab sorption unit, boils the solution. The water vapor which is thus produced goes to the condenser where this vapor is condensed. It then flows into the single coil (which is the evaporator on the cooling cyde). The air being cooled and dehumidified is blown over thfe coil. The water vapor Residential Air Conditioning 183 (through the process of absorption) is returned to the liquid gfrto and flows by gravity to the generator to be used again. The refrigeration unit is factory-sealed and contains a solu tion of lithium bromide and water which acts as the ab sorbent, water vapor being the refrigerant. Circulation of these fluids in the system is accomplished by differences in temperature and height of liquid columns, without moving parts. Control System Manual switches permit the owner to select heating or cooling, constant or automatic fan operation, and turn the system on or off. For protection of the unit a generator limit switch and a cooling circuit preventive control switch are provided. The former protects the generator from excessive input and is preset to operate at safe temperature levels both on the heating and cooling cycles. The preventive con trol switch keeps the unit from serving as a heating plant if the condensing water were cut off. Another protective de vice used in the year-round gas air conditioner is the low temperature control which prevents the unit from freezing as a result of improper equipment operation. A fan delay control delays fan operation until the heating coO has reached 140 F so as to prevent cold air circulation when heat is desired. Gas-Fired Water Chiller An air-cooled gas-fired water chiller is available featuring an outdoor absorption refrigeration section which circulates chilled water to indoor coils. Application requirements in both new and aviating construction are met by optional matching furnace coil, fancoil, and duct coil. These water chillers are currently built in a 3 ton size with an input of 120,000 Btuh. Cooling Cycle. Tbs hermetic absorption refrigeration cycle employs ammonia as the refrigerant and water as the ab sorbent. The continuous regeneration of the refrigerant fol lows baric absorption principles. High and low side operating pressures are comparable to those of air-cooled compression cycles. The only moving parts in the refrigeration cycle are the valves and float of the solution transfer device which circu lates solution from the absorber to the generator. Operating energy is derived from the refrigerant vapor generated within the cycle. Controls. Low-voltage remote thermostatic control for cooling only or for heating and cooling with manual switch over is provided. An attached switch base gives remote on-off control and selection of continuous or automatic fan opera tion. Safety controls shut off the gas in the event of excessive pressure or generator temperature. Heat Pump Year-Round Air Conditioners Residential heat pumps are either of the unitary or split system type. The.usual source of heat is either outdoor air or **ter. Due to a general lack of adequate water supply, air source equipment is predominant in the residential heatPump field. The modifications required to add the heating function to an electrically operated cooling system are mainly ti|e addition of a reverting valve to change the flow of re frigerant, automatic defrost means if air is used as a heat 60Urce, and additional temperature controls to accomplish year-round operation. The baric characteristics of the heat pump are discussed in rooredetail in Chapter58of the 2961 Guide Akd Data Book. The importance of the heat pump is due to the fact that the heating output always exceeds the electrical input energy. Although the ratio is a function of outdoor air temperature, operating conditions, and equipment design, the heating out put is on the order of 2Vi times the electrical energy input. The heating capacity decreases with decreasing outdoor tem- perature. A heat pump for winter heating has its greatest economic advantage in the sections of the country where the cooling and heating requirements are approximately equaL . As the outdoor temperature drops during the beating season the building heat loss increases and the heat output of the heat pump decreases. The point at which the heating re quirement matches the capacity of the heat pump is railed the balance pq/nt. For operation at outdoor temperatures be low the balance point some form of supplementary beat is required because, for economic reasons, the heat pump in residential applications is usually sized to meet cooling re quirements. In addition to supplying heat equivalent to the building heat loss, the heat to be supplied by the system and supplementary equipment includes the requirements for beat during defrost (in the case of air source units) plus the usual piping and pick-up requirements. Supplementary heat is fre quently supplied by electric resistance heaters which normally are used only during a small percentage of the total operating time depending on local climatic conditions. It is of interest to note that the operating hours for structures of the same size and design tend to be the same regardless of the geo graphical location, since areas requiring fewer hours of op eration on the cooling cycle will require more hours of opera tion during the heating cycle. LOCATION OF COOLING EQUIPMENT In general, both cooling and heating equipment should be located as far from the sleeping quarters as other circum stances permit. In many existing residences, the location of the evaporator coil (or coils) is governed by the present fur nace and duct arrangements. The location of cooling and heating equipment near bed rooms can be made acceptable through the use of suitable noise prevention and sound absorbing barriers as discussed in the next section Operating Sound Level. In the split system, the cooling coil is located over the fur nace, but the location of the water- or air-cooled condensing unit is quite flexible. The water-cooled condensing units are usually located near the furnace unless space availability or other considerations favor another location. The remote air cooled condensing units (or air-cooled condensers) are usually located outdoors adjacent to the residence. Proximity to neighboring houses is to be avoided. Locations at the front or rear of the residence are usually preferred. Proximity to areas that are likely to be used when the house is being conditioned should be avoided. This applies to porch and patio areas. Preferences of the family and their habits of living must be given consideration so as to keep all space as useful as possi ble and still locate the equipment in such a place that it can do its intended job and be accessible. OPERATING SOUND LEVEL One of the prime problems with residential air-conditioning installations is the operating noise level. Almost any degree of quietness in an installation can be had for a price. How ever, the numerical standards for describing sound levels have little meaning for the average person. It is difficult to ascertain from the prospective user in advance of installation just what sound levels will be acceptable and to describe what sound levels will result from any particular arrangement. Motors and motor drives, compressor, blower, pumps if any, and flowing air and liquids are potential sources of noise