Document wxLDVRGVZqYxL5Y5dqZdMO7B
CHG 01325
OCCUPATIONAL HEALTH CONSULTANTS. INC. Environmental Health and Safety Consultants
P.O. Box 3127 Freeport, Texas 77541
Telephone 409 733X233-33 24
ASBESTOS SURVEY ADMINISTRATIVE OFFICES OF ADMINISTRATION
BUILDING AND WITHIN LABORATORY
CHAMPLIN PETROLEUM COMPANY 1801 Nueces Bay Boulevard
Corpus Christ!, Texas
By
' Harry/N. Edwards Senior Industrial Hygienist and Toxicologist
June 27, 1983
NOTICE The information herein is presented in good faith and, while it may not be complete in scope, it is believed accurate and reliable. No representation, guarantee or warranty is made as to its completeness.
E- 000479
SUMMARY No asbestos fibers were detected in any samples collected in the administrative building or laboratory. This report contains methods, results, discussion and conclusions.
E- 000480
INTRODUCTION
At the request of Mr. Braxtont Routh of Champlin Petroleum Refinery,
an asbestos survey was made in the administration building and laboratory. The survey was made on May 23, 1983.
E- 000481
METHODOLOGY Airborne samples were collected by pulling a measured volume of air through a 0.8 ym Millipore filter mounted in a three-piece cassette. Tests were made open face on the'filter. Air was pumped using a Bendix BDX 44 pump calibrated to pump 2 L/minute. Calibrations were made using a Buck calibrator which is a primary standard. All samples were prepared and counted by S & B Laboratories, a certified laboratory, in Houston, Texas. Bulk samples were tested using the SKC test kit which gives only a positive or negative result. All samples were collected by Harry Edwards of Occupational Health Consultants, Inc. of Freeport, Texas.
E- 000482
RESULTS No asbestos was found in any of the locations tested or bulk samples examined (Table I).
E- 000483
DISCUSSIONThere were many particles coining from the air conditioning ducts. This was being seen on desk tops and throughout the building. The material is not asbestos, but a fiberous material. It seems that both buildings are overrun with termites which seem to be eating the insula tion materials.
E- 000484
<i
CONCLUSIONS No asbestos was found during this testing period. There should be no hazards involved with handling the fiberlass material.
j
3
fi
Tt
t. I i
t
E- 000485
RECOMMENDATIONS None at this time.
E- 000486
TABLE I
ASBESTOS LEVELS CHAMPLIN PETROLEUM COMPANY
Corpus Christi, Texas
LCOATION Eng. Sec. office 5.5,Occupant:.
Cummins, Pamela 491 60 7843 Office No. 7, Occupant:
Fragitt, Greg 516 62 5652 Office No. 2, No one present
Intake vent, upstairs
Laboratory. Rec. room Laboratory, Secretary's office
Laboratory, First bench, right
BULK SAMPLES
Above lab bench, first right
Entrance hall
LITERS SAMPLED
22
24 30 30 60 30
60
FIBERS/cc >5.0 m
<0.01
<0.01 <0.01 <0.01 <0.01 <0.01
<0.01
Negative Negative
There were many particles on filters, but most were fiber glass, none asbestos.
E- 000487