Document wxLDVRGVZqYxL5Y5dqZdMO7B

CHG 01325 OCCUPATIONAL HEALTH CONSULTANTS. INC. Environmental Health and Safety Consultants P.O. Box 3127 Freeport, Texas 77541 Telephone 409 733X233-33 24 ASBESTOS SURVEY ADMINISTRATIVE OFFICES OF ADMINISTRATION BUILDING AND WITHIN LABORATORY CHAMPLIN PETROLEUM COMPANY 1801 Nueces Bay Boulevard Corpus Christ!, Texas By ' Harry/N. Edwards Senior Industrial Hygienist and Toxicologist June 27, 1983 NOTICE The information herein is presented in good faith and, while it may not be complete in scope, it is believed accurate and reliable. No representation, guarantee or warranty is made as to its completeness. E- 000479 SUMMARY No asbestos fibers were detected in any samples collected in the administrative building or laboratory. This report contains methods, results, discussion and conclusions. E- 000480 INTRODUCTION At the request of Mr. Braxtont Routh of Champlin Petroleum Refinery, an asbestos survey was made in the administration building and laboratory. The survey was made on May 23, 1983. E- 000481 METHODOLOGY Airborne samples were collected by pulling a measured volume of air through a 0.8 ym Millipore filter mounted in a three-piece cassette. Tests were made open face on the'filter. Air was pumped using a Bendix BDX 44 pump calibrated to pump 2 L/minute. Calibrations were made using a Buck calibrator which is a primary standard. All samples were prepared and counted by S & B Laboratories, a certified laboratory, in Houston, Texas. Bulk samples were tested using the SKC test kit which gives only a positive or negative result. All samples were collected by Harry Edwards of Occupational Health Consultants, Inc. of Freeport, Texas. E- 000482 RESULTS No asbestos was found in any of the locations tested or bulk samples examined (Table I). E- 000483 DISCUSSIONThere were many particles coining from the air conditioning ducts. This was being seen on desk tops and throughout the building. The material is not asbestos, but a fiberous material. It seems that both buildings are overrun with termites which seem to be eating the insula tion materials. E- 000484 <i CONCLUSIONS No asbestos was found during this testing period. There should be no hazards involved with handling the fiberlass material. j 3 fi Tt t. I i t E- 000485 RECOMMENDATIONS None at this time. E- 000486 TABLE I ASBESTOS LEVELS CHAMPLIN PETROLEUM COMPANY Corpus Christi, Texas LCOATION Eng. Sec. office 5.5,Occupant:. Cummins, Pamela 491 60 7843 Office No. 7, Occupant: Fragitt, Greg 516 62 5652 Office No. 2, No one present Intake vent, upstairs Laboratory. Rec. room Laboratory, Secretary's office Laboratory, First bench, right BULK SAMPLES Above lab bench, first right Entrance hall LITERS SAMPLED 22 24 30 30 60 30 60 FIBERS/cc >5.0 m <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 Negative Negative There were many particles on filters, but most were fiber glass, none asbestos. E- 000487