M. H. DETRICK COMPANY* INSULATION DIVISION TECHNICAL DATA SHEET C L A S S___!LJ_P A G E___ L
DETRICK T-60 INSULATING FINISH
Detrick T-60 is a hydraulic setting insulating finish cement designed specifically for use on valves, pumps, fittings, and equipment treated with Thermon* high heat transfer plastic compound. It is mixed with water, then applied 1" to 1-1/2" thick. T-60 Finish improves the thermal efficiency of the system and affords protection for indoor or outdoor service.
As shown in the illustration, Thermon Plastic Compound is first applied over steam tracer lines or thermal electric systems as speci fied by The Thermon Manufacturing Company. This application of high conductivity Thermon Plastic provides an accelerated heat transfer rate from the tracer lines to the body of the valve or fitting. After the Thermon Plastic has set, T-60 is troweled over the valve or fitting. This further distributes the heat transfer and provides a durable finish.
THERMON COMPOUND
OCTRICK - T-60 INSULATING FINISH
REINFORCING HAIRPINS
APPLICATION
After the Thermon Plastic Compound is ap
OETRICK - T-60 INSULATING FINISH
plied but before it has set, wire hairpins are inserted in the compound to provide anchorage
TYPICAL * THERMCNIZED* VALVE SECTION
for Detrick T-60 Insulating Finish. The hair
pins are of soft wire, #18 or #20 gauge, approximately 1" long, with extended
legs. Depending on the size and shape of the valve or fitting being treated, the
hairpins are inserted on approximately 2" centers, setting them about 1/4" deep
in the Thermon Plastic Compound.
Detrick T-60 Insulating Finish is applied directly to the surface after the Ther-` mon Plastic has set, troweling it carefully into the hairpin reinforcement. Appli cation of T-60 Insulating Finish should be in a single layer, 1" to 1-1/2" thick as specified, mixing no more in advance than will be applied within two hours after water is added.
PHYSICAL PROPERTIES
Water Ratio Dry Coverage Material Requirements Density (Applied and Dried) Shrinkage (Wet to Dry, By Volume) Compressive Strength (Air Cured) Thermal Conductivity (k) @ 1000 F.
Mean Temperature Surface Treatment (when required) Shipping Container (Sewn Closure)
STORAGE
4-1/2 gals, per 50 lb. bag 25 sq. ft. 1" thick per 100 lbs. 4 lbs. per sq. ft. 1" thick 51 lbs. per cu. ft. Less than 2% 125 psi 1.47 Btu
Easily painted or weatherproofed 50 lb. paper bag
PLAINTIFF'S EXHIBIT
Store in a cool, dry location until ready to use.
St ENGINEER ED INSULATIONS
MHD-200 HEAT ENCLOSURE
May 1, 1959
*THERMON is a trade name of Thermon Manufacturing Co.