Document wrrQJonoX7B3KKy0rvon3gXqd
Hot for reproduction Original: English
iyfERHATIOHAli OjECTna^ECHinCAl CCHMISSIOU
TiyHKlCAIi OggtITTBB l]o^ 10: LIQUID XflD
OAgEoua* jiraisroiacs *
3us~c.0HM.iwEn iopt. imsuutibg ncioxpa OTHEIt THAI: ICfD^CC/iRibirouis
Comments of tho Italian National Committee on Potnawt 103(3cretari.at)l9i Guide for acceptance and maintenance of tranefomer aslmrel in equipment
lcg&aixlu.
Itajr 1975
The Italian Conittee finds the document generally acceptable but oonaldors that an extensive revision la necessary in line with the follotfing cosnantas
General
1) The document ehould only be Intended to give guidance on the aaeeeament of the oonditlon of the fluid in asksrel-filled transformers and on the means to be uaed to restore satisfactory properties. It is not intended to set rules,for the acceptance of eskarele supplied in new transformers.
For this reason, the title and tho text of various clauses require modification to remove this implication.
2) On aooount of the mixability of askarel with petroleum oils and the practical impossibility of removing such contaminants, it is recommended to emphasise the requirement that pumps, valves, piping and every equipment used in handling askarel should be thoroughly free of oil and greases. The adverse effeet of petroleum oils on the fire resistance of askarel should also be mentioned.
5) It is suggested that a new clause ehould be added dealing with topping-up of aakarel-filled transformers (mixability of different types of askarel, treatment of fluid before fll3.1ng~in and ao on).
In the 2nd paragraph, line 5# delete "and toxicological".
Clauae 2 - Aajsarol, fteneral characteristics
The 2nd paragraph should be replaced by the text of Sub-clsuse $.8 of
- Document 10B(Secretariat)21.
.
The tvo last sentences of the 4th paragraph on page 2 should be deleted.
In fsot the dleleotrie strength of any-liquid dieleotrlc of technical purity is not
s basic property of tho material but primarily depends upon its dryness and clear*-
liness.
.
.
Clause 3 - Evaluation of aslarsl received In new eouiaascit
The wording of the 3rd paragraph is not. consistent with the terms of reference of SC 10B. Thq follotfing wording ie proposed:
"Askarel ocntained in new equipment and exhibiting the foilowing
characteristics is oonsldered satisfactory". . -1-
HONS 047453
Assigned value for breakdown voltage (lEC Publication 156) should ba 50 kV minimum.
Thar* are eorioue doubts as to whother the Uniting value of loaa tangent and
the general abatements In the penultimate paragraph can be accepted ae they stand. A value of 0.10 at 25 C is certainly indicative of contamination (see also the
limits proposed in Document 10B(Secretariat)22) and possible effects on the serviceability of the /luid may be dependent on design and operational factors. A limiting value of 0.50 at 90 C, 50 Hz is oloser to our experience for voltage ratings of up to 20 1:7 and should tentatively be inserted, -he limit should ba
further reduced as voltage rating increases.
Qlmuse A - .Classification of Berries aged aakarels
It is considered thatr in spite of the obvious difficulty to set limits
applicable to all circumstances, soas sfforts should be nado to develop basio
principles on which to rely for the classification of a given askarel into one
of the listed groups.
.
The foilotring changes are caoaidered to be necessary in the Hat of properties and test methods on page 5:
Itorn 1
1 Delate ASTM D-2129.
Item 2
t Replace "electrio strength" by area]cdcncn voltage".
Items 7 and 9 t Reference should be to IEC Publications 250 and 247.
Item 8
1 Deists ASTM D-1807.
Items 10 and 11 1 Reference should be to I2C Publication 2961 (1971 )
Item 14
< ASCII D-1800 is rather troublesome. Infrared spectroscopy affords easier and safer detection and determination of hydrocarbons In askarel.
With regard to test significance, the following amendments are suggested:
Bleotric strength: 6th line, delete "dissolved oontominants".
fl^lnrddaa! Replace "ionizable" by "inorganic".
Dissipation factor: Lins 6, delete "moisture". The 3rd sentence should also be deleted.
Resistivity:
Ths 91 unit for resistivity Is ohm.m.
In esotlon B ths following tests should be added to the list: *0) Viscosity 9) Toluss of oil".
Ths use of s filter-press is often troublesome because of fluid leakages and volatility of askarel at 60 C. A sealed cartridge filter Incorporating a 15 on layer of finely-divided (0.06 to 0.10 mm) activated (20 h at 200 c) allumioa was found to be free of the above difficulties and effective In i wiving moisture, suspended particles and dissolved contaminants from contaminated aabmrels.
Clausa 10 - Handling materials
The suitability of materials to be used in contact with askarels can be tasted with the method described in Document lOB(3ecretarlat)22 and this should be mentioned.
-2
HUNS 047454
In the 3rd paragraph delete the reference to mineral oil.
Greater emphasis should be given to the last sentence of the clause, which should form a separate paragraph. Clause. 13Recommended handling procedures
fhe statement that no gloves should be used is in conflict with Sub-clause 7, of Document tOB(Secretariat)21.
The information given in the opening sontenoe of the 2nd paragraph would be improved by indicating-the maximum permissible concentration of asicarol vapours in ambient air (l mg/m per 0 h exposure).
MGNS 047455 Roproduoed in Switzerland Central Office of the IK 1, rue de Vsrsobd CH3IETA XKV 5 -