Aroclor Pollution Study
p.,,.nn,i: Ishmeal Ransaw and Andrew Nelson (J. L. Brown)
PfobUm: '
Evaluate the removal of Aroclor from the Anniston Plant effluent by carbon adsorption
Justification: Pollution Abatement
Summary:
In a 107 day pilot run, approximately 287,000 liters of waste water from the Aroclor sump were treated by passing through a series of four (4) packed-bed adsorbers (each adsorber was a five (5) inch diameter tube packed to a bed depth of 5.5 ft. with Pittsburgh's carbon type Filtrasorb 300). Test runs were made at 2 gpm/ft.2, 4 gpm/ft. and 6 gpm/ft.z flows. During the first 20 days.of this study there were periodic indications of breakthroughs2. This problem disappeared after backwashing was initiated on a periodic basis regardless of the pressure drop across the columns.
The following conclusions may be drawn from this study:
1. ,
The Aroclor level of waste water containing average concentrations of 4,795 ppb1 of Aroclor 1221, 1,525 ppb of Aroclor 1242 and 95 ppb of Aroclor 1254 can be reduced to <10 ppb total Aroclor upon passing through the first carbon bed at a 6 gpm/ft. flow with an expected carbon loading capacity
of 25* (based on the first column).
2. Backwashing frequency will have to be based on a factor other than pressure drop alone. This factor is necessary to pre vent the migration of small Aroc1 or-containing particles
1 ppb * parts per billion 2 Breakthrough indicated by effluent conccntrations>10 ppb
Aroc1 or. Appendix sections not included.
MONS 087485
Aroclor Pollution Study Research and Devveellooppmmeennt Report
Summary:
(cont'd.)
2. through the carbon bed. The backwash water contains an unacceptable Aroclor concentration; hence will have to be treated before disposal.
3. Based on an experimentally determined 25% loading capacity
and 6 gpm/ft. flow, the capital cost for treating a 200 gpm and 600 gpm is $25,000 +_ 30% and $45,000 + 30%, respectively. This cost does not include pumps, engineering or other
Indlrects. The total cost becomes $99,000 + 30% for 200 gpm flow and $129,000 + 30% for 600 gpm with the Inclusion of a carbon reactivation system.
Recommendations:
It Is reegmmended that Aroclor be removed from waste streams
that contain 60 mg/1 or less solids and Aroclor concentrations not exceeding 10,000 ppb by adsorption in a fixed carbon bed.
A study is presently in progress to evaluate the removal of Aroclor by adsorption on a less expensive adsorbent and then
removing the adsorbent by flocculation.
PR&D Chemist /dp