COMMENTS BY THE GENERAL ELECTRIC COMPANY ON "PROPOSED TOXIC POLLUTANT EFFLUENT STANDARDS
FOR POLYCHLORINATED BIPHENYLS" (41 FR 30468. July 23. 1976
INTRODUCTION
.
The General Electric Company Is a major manufacturer of electrical
capacitors and transformers whose dielectric fluids contain polychlorinated
biphenyls (PCBs). Consequently, we have followed diligently the develop
ment of the regulatory structure for PCBs, and we submit the following
comments regarding the proposed toxic pollutant effluent standards for
PCBs published In the Federal Register on July 23, 1976 (41 FR 30468).
He hope that our comments will assist the Environmental Protection Agenpy
In promulgating effluent standards for polychlorinated biphenyls (PCBs)
that are technically sound, clear and equitable In application, and In
compliance with the terms of the Federal Water Pollution Control Act. ,
Although these comments are directed specifically to the proposed
standards for PCBs, they are also relevant to two related Issues: (1) the
establishment of effluent limitations on PCBs for dischargers not covered _
by the proposed standards, and (2) the development of effluent limitations,
and guidelines for the 65 chemicals and chemical classes covered by the
same consent agreement* that established a deadline for the proposal of
these PCB effluent standards.
* Approved on June 9 by the U. S. District Court for the District of Col umbla, NRDC v. Train, 8 ERC 2120.
MONS 047384
J
0 -2-
In conformity with this agreement, the preamble to the proposed standards states that "In developing the standards proposed herein the Administrator has given careful consideration to each of the factors enumerated In Section 307(a)(2)... In addition, the Administrator has considered the availability of various methods of control and related technology by which discharge of PCBs might be eliminated or reduced." In Its Initial Notice of Proposed Toxic Pollutant Effluent Standards (41 FR 23576, June 10, 1976) the Agency presents Its justification for : giving "at least some consideration to ... the availability of control technblogy In setting standards under Section 307(a)..."
The Agency therefore first examined the available data base In oi^der to arrive at an ambient water criterion and then "examined feasible control technology to ascertain what concentration levels Industrial dischargers might be able to achieve In their effluents..."
Recognizing that "translating an ambient water criterion number to an end-of-the-plpe standard Is at best an Imprecise calculation," the Agency has decided (41 FR 23580) that "in any case where a discharge Is allowed, on the spectrum ranging from certain safety (a prohibition) to that uncertain point where harmful effects are caused and safety ends, a logical break . point Is struck where the very best that control technology can do Is required." To deal with those "few cases" where local receiving water conditions mjy be Inadequate to ensure "sufficient dispersion and dilution" of the pollutent, the Agency has proposed a Section 129.7 allowing "the cognizant regulatory authority to Impose such more stringent effluent limitations as may be required In order to achieve the ambient water criterion..."
HONS 047385
Thus, even though the proposed "ambient water criterion" Is not .i
used directly In the derivation of the proposed effluent standards (as jt
was by the Agency In Its earlier proposed rule making, 38 FR 35388 et seq.).
It could serve as a basis for some future ad hoc tightening of effluent
limitations.
__ '
Our comments, therefore, address two main Issues:
(1) The scientific approach used by the Agency In arriving at
an ambient water criterion for PCBs. We feel that the Agency should
distinguish between two major groups of PCBs. and that It has failed to / 1
establish a logical, straightforward derivation of Its proposed ambient:
water criterion from the relevant scientific data base.
(2) The technological approach used by the Agency In proposing ;
Section 307(a) standards. We feel that the Agency has gone beyond the
scope of the Federal Water Pollution Control Act In requiring the Institution
of process changes by existing plants within one year of promulgation of
standards under Section 307(a). We also suggest Improvements for a revised
version of the analytical method for PCBs specified by the Agency for
reliable determination of compliance or non-compliance.
i
' . COMMENTS ON ISSUES
,
1) The Scientific Approach Used By The Agency .
; V
We find two major areas of weakness In the approach used by the Agency
|n arriving at an ambient water criterion of 0.001 ug/1:
a) The reasoning used by the Agency In deciding (41 FR 30473) th^t
"there appears to be no sound basis for setting different criterion numbers
or standards for different Isomers."
b) The absence of any logical, straightforward derivation of the
proposed ambient water criterion from the relevant scientific data base.
MQNS 047386
J ................
0
-4-
a) Definition of PCBs TSec. 129.4(f)! Does Not Differentiate Amona Isomers and Homoloas
There Is neither chemical nor biological Justification for conslderIng all PC6 Isomers and'homologs to be equivalent In respect to the 1
criteria for toxicity used by EPA In selecting pollutants for the list
of toxic pollutants (38 FR 24342).
An Interdisciplinary group of life scientists on the staff of GE's
Corporate Research and Development Center recently conducted an exhaustive analysis of the available toxicological and environmental literature on;PC8s. This analysis disclosed substantial evidence of large differences In toklclty, bloaccumulation, and environmental persistence among different commercial grades of PCBs and among different test species.
'For example, large ranges of toxicity have been seen In animal studies that focussed on the nature of the effect produced by similar doses of different Aroclors, Including studies conducted by the same group of workers In the same laboratory. Thus, the same group (Kimbrough, Burse et al) That reported that Aroclor 1254 or 1260 In rats could provoke a progression pf hepatic changes, beginning with hypertrophy and pyperplasla, and going on ' to adenoflbrosls, neoplastic nodules, and carcinomas (cited under "(4) _
Carcinogenesis" on p. 30472) also reported parallel studies Indicating that none of these toxic manifestations occurred with Aroclor 1242 or 1016.
Similarly, the Initial liver response to Aroclors 1254 and 1260, l.e. marked Induction of drug-metabolozlng enzymes, was absent when Aroclor 1016 wap used.
The extensive Japanese Investigations of the Yusho poisoning episode,
particularly the more recent findings summarized by Dr. Kuratsune at the
MONS 047387
-5-
National Conference on PCBs In November 1975, have disclosed the origin Of the huge ranges In toxicity exhibited by different grades and even different specimens of the same grade of PCB. The actual toxic agents In the PCBs have been Identified as the polychlorodlbenzofurans (PCDFs). Kuratsune showed that It was the PCDFs, not the PCBs, that were chronically accumulated In humans and that It was the levels of PCDF, not those of PCB, that correlated with toxic manifestations In man. It Is remarkable that the very first clinical report on PCB poisoning In humans, that of Jones and Alden In 1936, clearly recognized that the toxic action had tp come from an Impurity; however, the Impurity was not actually identified as PCDF until more than 35 years later. Clear-cut correlations of toxicity With PCDF level were reported for chickens by Vos et al In 1970-72. !
We reviewed all relevant data In the scientific literature describing chronic PCB toxicity studies on mammals. We then constructed Table 1, In which columns 3, 5, 6, and 7 present our best quantitative estimates or calculations, from these published data, of PCDF concentrations In the PCBs used, of "maximum no-effect" concentrations of PCB In food, of food Intake rates, and of "maximum no-effect" dose rates. For comparison, we have * included Kuratsune's data on humans. Among the animal studies, we note In particular that the lowest "maximum no-effect" concentrations and "maximum no-effect" dose rates were associated with the highest estimated PCDF cont' centratlons ( 1 ppm PCDF In PCB). Furthermore, the "no-effect" numbers for hepatic effects In rats are significantly higher for Aroclor 1016 (Which was estimated to have no PCDF) than for the higher chlorinated Aroclors (which were estimated to have about 1 ppm PCDF In the PCB used.)
moms Oi.738*
(1)
Test Subject
Kur.an
Monkev (adult) Monkey (infant)
Mink
n
Dog Co
Rat
;
. n. '
1
W
^
TABLE I.
(2) PCB/PCDF Tested
CALCULATION OF MAXIMUM NO-EFFECT DOSE RATE FOR PCB/PCDF COMPOSITIONS
(3) Ppm PCDF
(<) ' Major
(S) Max. no-
(6) Intake rate,
(7) Maximum No-effect
dose rate,
in PCB (Estimated')
Toxic Effect
effeet, ppm PCB in food
kg.food/kg. body wt.-day
mg.PCB/kg. body wt.-day
Xareclor-400 . (heat aged)
' Aroclor-1248 (shelf aged)
Aroclor-1248 '
10,000*
>>111 ^lb
Dermal ' Dermal Dermal
* ** (0.5g.)c
. <2.5d
>300. e
(01000 day)*"**
0.04 0.04
'
oc .007 <0.1 >i2.
Aroclor-1254 (metabolized) . Aroclor-1254 '
Aroelor-1260 Aroclor-1254 Aroclor-1242
Afoclor-1260 Aroclor-1254 ' Aroclcr-1242
Aroclcr-1016
10
-vlb
o la
ib \rlb 'vim 0b
Hepatic
'n
Hepnatic if
Hepatic) ' 'f "J
n
<0.6f
<5. *
no. h
<100.>100.
..
Vio1
0.05 ' If .
'
.
0.1103
. '
0.05
ilOO^
....
<0.03
. <0.25 *>0.3 <3. >3.
00.5
<5.
Sources
s. Xuratscne, 1976. b.Bowes et al., 1975. c. Xuratsune,1972. d. Barsotti et al., 1975. e. Abrahamsonand Allen, 1973. f. Platanow and Karsted 1973. g. Ringer et al.,1972. h. Xeplince: et al., 1971? Calandra, 1975; as interpreted by FDA, 1973. i. Keplinger et al., 1971; Calar.dra, 1S75; Kimbrough et al., 1972; as interpreted by FDA 1973. j. Burse et al., 1974. k. Assumption of PDA, 13 73. is. Ax and Hansen, 1975. n. Estimated from progressive increases in toxicity observed in going from early to late (Ref.d) tests, o. Estimated from use of liver, known to concentrate FCDF relative to ?C3 (Ref.a) as mink food.
* This figure is the maximum noj-effect dose in grams of PCB.
** This is FDA's assumption of number of days over which dose is accumulated by humans.
7-
Even more significant was the demonstration by the Japanese group
that the particular PCDF's chronically and specifically accumulated by the
human liver were the penta- and hexachlorlnated homologs. Since the PCQF's
were found to arise from the PCBs upon aging, particularly under conditions
favoring thermal oxldatfon of the PCB's, It Is evident that the source of the
chronically toxic penta- and hexachloro PCDF's must be the corresponding
penta- and hexachloro PCBs.
In this connection, it Is significant that Aroclor 1016, which Is
essentially the only Aroclor used by the capcltor Industry since 1971, was
specifically designed to contain virtually none of these more environmentally
persistent and potentially toxic penta- and hexachloro homologs. The yidely-
quoted Monsanto prospectus Indicates a total content of these "higher hOmologs"
as 1.1*; however, the product quality control limit was set at 0.4*; and
the actual material shipped to GE during the past two years has usually
contained less than 0.1*. This contrasts with the 100-fold higher level
of "higher homologs" found In Aroclor 1242 (typically, around 9*) or the
1000-fold higher level In 1254 or 1260 (>-70*). Thus, there Is a clear
chemical basis for the strikingly lower toxicity levels actually observed
In mammals whose diet contained Aroclor 1016.
,
Toxicity In fish probably results from a general anesthetic effept ' 1V
of the PCBs themselves rather than PCDF activity In most cases; even so,
there are significant differences In chronic toxicity among the various
product grades, which appear only partly relatable to differences In
bloaccumulatlon. Reported values for bloaccumulatlon of Aroclor 1016
In various species and life stages of fish run from 2,500 to 55,000, and
are usually 10-20,000. Bloaccumulatlon of Aroclor 1254 Is typically 2-5
HONS 047390
fold larger. In continuous flow chronic toxicity tests, reported LC 50 1 values for various species and life stages of fish cover the range 11-81 ppb for flroclor 1016 (Hansen, Parrish and Forester, 1974) and about 1-5 ppb for Aroclor 1254 (Nebeker and Pugllsl, 1974). There Is one report of "significant mortality" In sheepshead minnow fry at 0.1 ppb of Aroclor 1254; the same authors also reported, however, that 100-fold higher levels were required to produce a comparable effect with Aroclor 1016. (Nebeker and Defoe, 1974).
In summary, all available evidence Indicates that Aroclor 1016 Is 10- to 100-fold less hazardous than the higher PCBs to fish; 100- to 1000 fold less hazardous upon direct exposure to animals, and probably 500- to 5000-fold less hazardous If exposed via the fish bloaccumulatlon - fish consumption route. Inasmuch as there Is no analytical problem In distinguish Ing among the different degrees of chlorination present In a given PCB sample It is scientifically justified and practically feasible to.establish separate ambient water criteria for PCBs with degrees of chlorination < 4 Cl/biphenyl (which represent 651! of current U.S. production) and for PCBs with degrees of chlorination Jr 5 Cl/biphenyl (which are the homologs most perslsten^ In' the environment and potentially the most toxic).
Ue believe that separate criteria for the higher and lower PCBs vjfOuld be in the public Interest for three reasons.
o The development of Aroclor 1016 by Monsanto,and Its subsequent use by capacitor manufacturers beginning In 1971, represented a major and technically successful effort by Industry to reduce to a negligible levfel the most environmentally persistent components of the dielectric fluid used in capacitors. Failure of the proposed rules to give any
MONS 047391
-9v
recognition to the differences between the toxicity and persistence
of different commercial grades of PCBs would certainly discourage
other manufacturers from attempting to remove objectionable impurities
from other productsln the future.
o A regulation that attempts to discourage the use of one substance
on the basis of a gross exaggeration of Its toxicity Increases the likeli
hood that It will be replaced by a substitute that may In fact be >
environmentally less desirable than the original substance.
o Although the proposed effluent standards apply only to manufacturers
of PCBs, capacitors, and transformers, the ambient water criterion <ould
be used as a basis for regulating other dischargers, such as paper Allis,
.whose effluents contain Aroclor 1242 because they recycle paper containing
that material. A water quality criterion that recognized the more benign
nature of Aroclor 1242 compared to higher chlorinated PCBs, which were
not used In paper products, would protect aquatic life and still enable
the public to enjoy the environmental benefits of recycled paper.
b) Derivation of Proposed Ambient Water Criterion
,
- The criteria that are most defensible, and that best serve the public
Interest, are those that follow In.the most.logical and straightforward.manner
' from the demonstrated scientific facts of the situation. The establishment
Sq . .
!
of such criteria requires (1) a thorough, critical evaluation of the available
toxicological data, In order to separate the solid, self-consistent facts
from the anomalies, extrapolations, and Inferences, and (2) a clear statement
of the safety factors used In proceeding from any "maximum no-effect dose"
thereby established to the proposed criterion. If such safety factors hve
been generated ad hoc, then the rationale behind them should be Indicated.
MOWS 047392
-10-
The preamble to the proposed standards contains a series of categorical statements relating to the reported toxicity, carc1nogenes1$, and human health effects of PCDs, and to the persistence, mobility degradability, bioaccumulation and blomagnlflcatlon of PCOs, These state ments summarize the highlights of "the extensive data base set forth In the criteria document" (which Is referred to In Appendix A), and lead EPA to the conclusdon that "a criterion level of 0.001 ug/1 would appear to avoid adverse effects to most aquatic organisms..."
However, the only direct connection made by the Agency between the biological data and the proposed criterion Is Its statement that "This Jevel Is based primarily on the bloaccumulatlon properties of PCBs." But, In fact, the Agency does not develop any such quantitative derivation of the criterion from bloaccumulatlon data. Instead, It says: "Based upon a bloaccumulatlon factor of 274,000* a concentration of 0.001 ug/1 would result In bloaccumulatlon to 0.274 ppm In flesh, which Is below the dietary levels which have beep, shown Injurious to aquatic birds and mammals who may feed upon them." (underlining added). The Agency goes on to say: "In addition, however, there Is evidence that In some waters some fish bloaccumulate at rates roughly ten times this', and In waters where the chronic level generally exceeds 0.001 ug/1, such as Lake Michigan, there 1$ evidence of sublethal toxic effects on fish." None
, of the foregoing provides any rational basis for choosing 0.001 ug/l as the ambient water criterion.
* The upper end of the range the Agency says Is found "after prolonged
esposure In the laboratory."
MONS 047393
-11-
Even after proposing this ambient water criterion, the Agency
proceeds to raise doubts about Its adequacy In Its statement that "the
Agency recognizes the possibility that such water quality level may not
provide absolute safety.for all organisms In all waters," and "there
probably Is no numerical concentration level above zero which one can at
this time say with great confidence provides an `ample margin of safety*
for all organisms under all circumstances." Furthermore, the Agency gbes
on to say that "even If every point source discharge were prohibited, PtB
concentrations In the water would remain for a long time not only above
zero, but in some water bodies, above .001 ug/1. Moreover, since the
capability does not exist presently to measure PCB concentrations below
0.001 pg/1 with any reasonable degree of reliability, no useful purpose
would be served In establishing a criterion number below this."
In essence, the Agency appears to have adopted the position that no
level of PCBs In the ambient waters provides an "ample margin of safety,"
and Is setting an actual numerical value at what It believes Is the lowest
level of analytical detectability. (On this point the Agency appears tp
be Inconsistent, because the analytical method specified for PCBs In Section
129.105 states that "the limit of detection Is approximately 1 yg/l-for .
each Aroclor mixture.")
r
There Is no doubt that some PCB/PCDF systems are toxic, that they
do bioaccumulate, and that safety factors are required whenever one Is
attempting to regulate exposure to a toxic agent that Is difficult to detect
(e.g. PCDFi) via the level of a more readily detectable congener or precursor
(e.g. PCB). However, regulation should be derived from sound data. Height
MONS 047394
J 0 -12-
must be given In the regulatory process to the established, self-consistent
portions of the data base rather than to values reported by Individual
observers.
2) Technological Basis.for Proposed Effluent Standard.
;
a) Control Technology Required
We can understand the pragmatic approach of the Administrator In
Interpreting the language of Section 307(a) to authorize consideration pf
control technology In setting toxic pollutant effluent standards. However,
because Section 307(a) contains no explicit language on control technology,
the Administrator should look for guidance In this area to those sections
of the Act that do require specific levels of control.
For existing plants, such guidance Is provided by Sections 301 and
304, which call for effluent limitations that shall require the application
of BPCTA (1977) or BATEA (1983). The present proposal, as It applies to
existing plants, Is neither BPCTA or BATEA. Instead, It more closely
resembles Section 306, which applies to national standards of performance
for new sources. Section 306 requires "a standard ... which reflects the
greatest degree, of effluent reduction ... achievable through application
of the best available demonstrated control technology, processes, operating
methods, or other alternatives. Including where practicable, a standard `
permitting no discharge of pollutants." Note the striking parallelism :
between the language of Section 306(a) and the current proposal that "the
Administrator Is requiring that discharges be prohibited where possible
and that other discharge comply with the very best results which available
technology can achieve." Including specific process changes and operating
methods, such as replacing steam jets with mechanical pumps and replacing
detergent washing with solvent vapor degreasing (underlining added).
MQNS 047395
0 -13-
We understand the Intent of the law to set more stringent effluent limitations for new plants than for existing plants and to require exist ing plants to meet more stringent limitations by 1983 (BATEA) than by 1977 (BPCTCA). Ue also understand that under Section 304 the Administrator Is directed to consider process changes In his assessment of BAT, which would be applicable to existing plants. But the timetables set forth In the Ant certainly do not authorize the requirement that these proposed rules would Impose, namely that existing plants must Institute process changes wlthjn only one year of promulgation.
In light of the foregoing, the Administrator should amend the proposed standards to make the Items listed In the column "pype of technology applied" (p. 30475) that relate to process changes* applicable only to new sources. Existing sources should be subject only to requirements Involving treatment technologies (e.g. carbon adsorption), not process changes.
* E.g. "Replace steam jets with mechanical pumps" and "Replace (deterpent
washing water) with solvent vapor degreasing."
j
HUNS 047396
-14-
b) Analytical Method Acceptable (Section 129.105)
We have reviewed the method specified In 40 CFR Part 136 for PCBs
(NPDCS, Appendix A, FR 38, No. 75, Pt. 11) and have compared the procedure
and the claims made for It with our own experience in analyzing Industrial
effluents for PCBs.
We have two comments concerning the use of the EPA method to establish
compliance with an effluent standard.
1) The published method falls to specify the details of the procedure
to be used In obtaining effluent samples for analysis. In our experience,
the scatter among the results of single analyses on successive samples of a
given waste stream Is far wider than the scatter among successive analysed
on aliquot portions of a single sample. Standardization of sampling pro-:
ccdures Is essential If results obtained on samples taken at different tinjes
are to be meaningfully compared either to each other or to a prescribed
effluent standard.
2) Our experience and that of other laboratories offers qualified '
support to the EPA claim that "the limit of detection Is approximately
1 ug/1 (1 ppb) for each Aroclor mixture." When blanks are very low, and
no Interferences are present, and the calibrating standard Is qualitatively.'
the same as the sample, this limit Is reasonable. The results of a recent ASTH
round robin test indicate that the 95* confidence limits at the 1 ppb level
ranged from + 25* to + 75* of the reported value for a single analysis. Ip
this test the samples used were pure Aroclors In distilled water and one >
sample of river water. In the real-world sequence of Industrial sampling,
sample preparation, sampling handling, and analysis, the reliable limit of
047397 mons
J -150
detection may range from 1 to 10 ppb, and the 95% confidence limit for a single determination at the 1 ppb level may be s i 100%.
We believe It Is essential that EPA prepare a revised version of Its proposed analytical method that will Include the following Items:
1) A description of acceptable sampling procedures. 2) A description of acceptable methods for removing or correcting for Interferences likely to be present In Industrial waste water streams. (The present version refers primarily to pesticide-type Interferences, which are unlikely to be present In Industrial samples). 3) A well-documented statistical analyses of the method as applied : to Industrial waste samples so that decisions on compliance with the effluent standards as promulgated will be based on a realistic understand ing of the confidence limits associated with results reported by dischargers
Submitted August 19. 1976