Document wrDvgxzkz1j22qnmgYn3rY3wV

Ed Smith - Anniston March 5. 1969 PLANT SPECS AND #5 STILL PUMP CEA 2080 R. S. Tates - CEO E. Voss G. Chi so R. Hanpt A. Haydel H. Brazil ton Concerning tha protective coating of structural steel, the recommendation of a three coat Epoxy system seems to meet favorably with Jim Chism, our painting specialist. He would also like to recommend the following coatings: Primer Carbo Zinc No. 11 2.S mils Dry Seal Carbollne No. 188 HB 4.0 mils Ory Finish Carbollne No. 188 3.0 mils Ory Regarding the Taber pump for IS still -- In extensive discussions with John Muehlberg, Taber Vice President, concerning a performance guarantee for pumps of less than 1 ft. NPSH (1. 2. and 3 stills), the possibility of using a pump similar to that on f4 still was pre sented but Mr. Muehlberg said this pump would not pro duce over 225 gpm at 66 ft. TDH. Where does this leave us on 15 still pumpf Ed Smith /*P TOWOLDMONOQ48215