Document wrBmNNjNa47dNw4ezykLKmmkE
M onsanto
MONSANTO INOUSTBIAL CHEMICALS Ca 800 N. Lindbtrgh 8oulavrd St. Louil. Missouri 63186 Phone: (314) 694-1000
October 24, 1975
Dr. Robert A. Stenger General Electric Co.
John Street Hudson Falls, N.Y. 12839
( '
Dear Bob:
I just received your 10-17-75 letter posing two questions about our recent analyses of water for PCBs. Regarding the first question about the two values we obtained on the Ft. Edward bridge sample, we feel confident that the lower value is more accurate. In my 10-16-75 letter to you, I did not include the higher value. As I indicated during our phone conversation, we feel the higher value was in error because of cross contamination from water sample "B" sent to Dr. Crow. We were unaware of the very high (3200 ppb) concentration of PCB in "B" and did not take special precautions to prevent PCB migration through lab air, which probably contaminated nearby samples concurrently being extracted. This emphasizes the care which must be exercised when sampling and analyzing for ppb levels of PCBs in the
presence of potential sources of contamination.
As a matter of principle when analyzing for PCBs, we always use multiple (3) extractions on unfiltered water. We also extract (rinse) the container thoroughly. These precautions help insure accurate sampling and analysis. Woodson-Tenent Laboratories assure us that they also
follow these procedures, as outlined in ASTM Method D 3304.
I hope this answers your questions.
Sincerely
ss
bcc: W. C. Hammann R. E. Keller W. B. Papageorge
Dr. James P. Mieure Research Group Leader
W. R. Richard J. C. Weber D. Wood
unit of Monsanto Company
IDS 003085
V*
WATER PCB-SD0000001771
GENERAL ELECTRIC
COMPANY
JOHN STREET, HUDSON EA11S, NEW YORK 12839 . . . AREA CODE 518, TELEPHONE 747-3341
INDUSTRIAL AND POWER CAPACITOR DEPARTMENT
October 17, 1975
Dr. James Mleure
Monsanto Industrial Chemicals Co. . 800 N. Lindbergh Boulevard St. Louis, Missouri 63166
Dear Jim,
Thank you for your call yesterday to review the results of recent analyses. One question on the Fort Edward bridge sample, where you obtained two values. When you used the second method, adding some hexane to the container, were multiple extractions used to check for extraction completeness? If not, perhaps that is another possible reason for that result coming out lower.
. '
As far as a report on Woodson-Tenent's caoability goes, Mike Modan agreed that your verbal report is sufficient for now. Perhaps it would be good to have a trip report by Bob Kaely in your files however, just in case any questions on this come up in the future.
Another item that occurred to me relates to the question of filtering water samples. As you know, most natural water samoles and those of our
main effluents contain some suspended solids. It is our practice to extract the whole sample without filtration. Is that the way your group and Woodson Tenent proceed as well? If not, I think no filtration should be performed.
I received the bibliography and found it most helpful. Thank you very much for sending me a copy.
/baw
Yours truly
Robert A. Stenger, Mgr Engineering Laboratory
IOS 003086
WATER PCB-SD0000001772