Document wqqDmBM2m4Z7656pQRmgvQDOV

> mo.hAl CtNTtfl FOR lO INOU5T5IAL health 10 14 Ba'JAO*iAy CINCINNATI, OHIO <55102 DEPARTMENT OF HEALTH. EDUCATION. AND WELFARE PUBLIC HEALTH SERVICE January 17, 1963 REFER TO: Mr. H. P. Hoopes Technical Director Pabco Industrial Products Division 475 Brannan Street San Francisco, California 94119 Dear Mr. Hoopes: In our survey of the Emeryville plant last September we proceeded in the same general sequence as the product, i.e. nixing, forming, curing, finishing, inspection, packing. The "hopper room" was the room between the finishing foreman's office and the machine shop where the dust from the collectors dumped into hoppers. This room was only occupied about five minutes per hour by a worker wearing a respirator. If the mask is of an approved type and -is worn prop erly, he should not be overexposed. However, the dense cloud of dust from this room would occasionally drift to other parts of the plant. Thus the high count (7.2 mppcf) near the oven unloaders was probably due to the hopper room. . The high concentration (12.2 mppcf) obtained for the block splitter in finishing may result from either the hopper room cloud or in adequate local exhaust on the machine, or both. No other concen trations exceeded the present TLV of 5 mppcf. As I understand from conversations at the plant the entire dust collector system is to be revised and this should eliminate the hopper room problem. Other engineering changes may be desirable to reduce dust concentrations as much as possible since the pre sent TLV nay be too high. Please let me know if I can answer any other questions. vsr*, J4rj ,, ^ucr. ^4, &<5r Sincerely your3, i Jeremiah R. Lynch /i\sst. Chief, Environmental Activities Field Studies Occupational Health Program K.'S ' ps*?: VwiriV tr-secr E-isSr jy'TPrF* hv>.i * &ixv'.- -- ijV-. t- January 11, 1953 Hr. Jarstaiah E. Lynch Asst. Chief, Eavironsasntal Aciivitisi Fiald Studies Occupational Health. Program* Department of Health, Education, and Welfare 1014 Broadway Cincinnati, Ohio 45202 Dear Jerry: I appreciate vary mich your lettas of January 2. Before I discuss the rasulta of your ta3ts in detail with tha plant, X aa wondering if you might more specifically pinpoint the areas of sampling referred to in tha table attached to your letter. Tha area defined aa *'Eopuar Eooui" stands out a* a high concen tration ara-a. We are looking forward to hearing frea you on this aa t^ll as the complata report including the results of fiber count on membrane filters whan av.ilabia. Yours very truly. HPH/bjs be: F. A, IJordstrom K P. Eoopee, laconical Director Poona industrial Products Diviolo DEPARTMENT OF HEALTH. EDUCATION. AND WELFARE PUBUC HEAUTH SERVICE iNAL CtNTSR FOR 0 IN0l-J > TRl AC H - ALTM IOt-4 BPOAJrfAY Cl NCIN.SATI, OHIO 4S202 January 2, 196-7') $ P REFER TOr Mr. H. P. Hoopes Product Manager Fiberboard Corp. 475 Brannan Street San Francisco,.California 94107 Dear Mr. Hoopes: The preliminary results of the impingar samples collected during the survey of the Fiberboard insulation plant at Emeryville, California are enclosed. These samples were collected and counted according to the standard method of the American Conference of Government Industrial Hygienists and are comparable to the Threshold Limit Value of 5 million particles per cubic foot established by that body. However, since these samples were collected for the epidemiologic purpose of defining the average exposure of a group of workers in a operation rather than for the usual industrial hygiene purpose of locating, and evaluating the heavily exposed individual, the results may not be comparable to' industrial hygiene survey data.-' A complete report including the results of fiber counts on membrane filters will be sent to you as soon as counting is completed. Your assistance and cooperation are appreciated. Sincerely yours. Jjit 5 /Or.^03 Enclosure sTr/' <vv -------"v--- Lynch:} , Environmental Activities Field Studies Occupational Health Program T f i v35sei LH>i* s<-.- CAcr ff. I