Document wqjDmXzyBJ4D1rebMDe5074e4

/ ^ ^ ,-tc of Analytic Chemistry ity of Stockholm ` T STOCKHOLM 50 ' ' THE OECD STUDY OP ANALYSIS OP PCB , December 1966 trotee concerning samples eent to OECD members September 1966: ampoule 1 * synthetic mixture of PCB fractions from preparative GC} ampoule 2 - induatrially-ueed PCB mixture* PCB (j^olyohlorinated Mphenyls) is the abbreviation used by this Institute for the 'residues' of the mixture of compounds found In nature in residue analysis for chlorinated pesticides* Aocording to the technical literature, PCB - under several trade names - has been in considerable use for a variety ^ of technical purposes since 1929, but never as a pesticide* It is assumed in this laboratory that all technical PCB la manufactured by the chlorination of biphenyl* ^ We have proved by mass epectrometric analysis that the PCB mixture most often used industrially consists of compounds containing between four and eight ohlorinee per molecule. If it is assumed that the chlorines are distri buted between the rings almost equally, 102 different PCB compounds are possible, aa the enclosed report discusses* We have shown that at least 24 of these are present^ since some may have similar retention volume, this number may be larger. Owing to the large number of PCB compounds possibly present, quantitative gao-chromatographlo analysis is difficult* Using an electron capture detector the response of closely related isomers may vary considerably, and thus a correct scheme for calibration of individual BCD-responses has to be found. O Since different methods of technical monufacture are very likely to give somowhat different isomeric composition, further calibrations may have to be done during the quantitative analysis of an unknown technical sample* In ^ residue analysis a further complication may arise from the partial metabollsoi of PCB, which may lnorease the content of the more stable PCB Isomers. If these limitations are born in mind, it is clear that quantitative residue analysis of PCB cannot yet be very accurate. However, the wide-spread presence in nature of PCB demands prompt analytical activity and the two ' samples (PCB 1 and 2) now circulated among the OECD laboratories together with the results given In this note may be found useful in standardising the analysis of PCB within the above limitations. We have attempted, in the following way, roughly quantitative analyses for the compounds which produce the 14 peaks marked on the enclosed chromatograms* While resolution is Incomplete, the numbers of peaks and their relative areas were the same for both columns* It was therefore possible to determine by CC/M8 the number of chlorine atoms per molecule in the major components of Z *tl S *0 SNOW 2. peak. The total chlorine present in the original FOB mixture, and Its ,13tri button between the different peaks, was determined by GC-mlcrocoulometry using the earns column. These values were used to determine the amounts of individual FOB components present in each peak, and hence EC-detector respon ses. The table lists data obtained for the original FCB mixture (ampoule 2). Analyele^of induetrlally-used PCB mixture (OECD ampoule 2) Peak No 1 f 2+2' 3 4 a 5 6+7 8 9+10 number of chlorine per molecule 4 . 5 + 4 (oa 35% + 65#) 5 5 5 6 + 5 (ca 35# + 65#) 6 + min of 5 6+6 . 11 6 12 8 ev min amount of 7 13 14 3 i* n 8 ' " n x) Data obtained on SF-9<*-column with EC-deteetor # T.4g 1'- 4 16.88 5.84. 11.4, 15.3, 12*65 11* 59 *.19 2.47 2.0j 100. 9 In our routine analyses we have up to now reported the total sum of PCB components. Be realise that this procedure is not strictly correct, and it may be better in future to aum over each of the five individual molecular weights. Stockholm December 1968 S.Jensen "B,Sued O.Widmark HONS 045743