Document wqa3Eo7X0VrnjDbVQ2E274wdV
Hoffman Specialty Co., Inc.
Heating Systems
Steam and Hot Water.
LOW, MEDIUM AND HIGH PRESSURE THERMOSTATIC TRAPS
Low Pressure
Medium Pressure
High Pressure
Low pressure traps have brass bodies, caps, and union nut and tail piece. 17C is made in
Angle, Swivel and Vertical patterns. 8C is made in Angle and Straightway patterns. 9C is made in Angle pattern only. Thermostat and seat both renewable.
No. 17C Capacity 200 sq ft EDR 15 lb pressure in. connection No. 8C Capacity 400 sq ft EDR 25 lb pressure % in. connection No. 9C Capacity 700 sq ft EDR 25 lb pressure 1 in. connection
Medium Pressure Nos. 8 & 9 and High Pressure Nos. 8H & 9H have all bronze bodies
and caps with union nut and tailpiece.. Thermostats are 6 diaphragms of special noncorrosive metal. Thermostats and seats are renewable. }/& in. sizes are furnished in Angle, R.H., L.H., and Straightway patterns, others in Angle only. Medium Press.
50 lb limit. High Press. 125 lb.
Capacities--Lb Condensate per Hour--Working Pressure--Lb per Sq. In. Gage
Trap*
5 15 25 50
Traps
25 / 50
100 125
8
>/.' 100 180 235 400
8H
vr 235 400 550 590
8
Vi' 125 225 300 490
8H
Vi" 300 490 650 720
9
V*' 225 350 450 650
9H
V.* 450 650 875 950
9H9 \m 325 500 625 850
1' 62$ 850 1125 1250
FLOAT TRAPS, DIRT STRAINERS AND SUPPLY VALVES
Float Traps are available in large capacities and four pressures, 15, 30, 60 and 125 lb. Used for venting and draining risers, steam mains, unit heaters, blast coils, etc. Hoffman Float Traps are made for easy servicing with all working parts mounted on cover. Remove four bolts to expose all parts. Pipe sizes are from % in. to 2 in.
Radiator Supply Valves are made in sizes from to 1^ in. in Angle and straightway patterns. Brass bodies, union nut and tailpiece. No. 80 has reversible cone disc andt bevelled seat. No. 85 is Modulating type. Both are packless.
Hoffman Dirt Strainers are self-cleaning Y type. Brass strainer cylinders and cast
iron body. Sizes H to 2 in. for 125 lb pressure. Should be used in line ahead of all' float and thermostatic traps.
CONDENSATION AND VAGUUM PUMPS
Condenser Pump
Hoffman-Economy pumps are available in varying ca pacities, D.C. and A.C. current, single, two, or three phase, and in pressures up to 200 lb. Also made in single and duplex units for different capacities and pressures.
1214
Vacuum Pump
Hoffman Specialty Co., Inc.
Heating Systems
HOFFMAN HOT WATER CONTROLLED HEATING
For PANEL or RADIATOR SYSTEM
The Hoffman method vastly improves the ordinary forced hot water system by the
application of Continuous Circulation. This method accomplishes 4 major improve ments. 1. Avoids intermittent bursts of heat to the radiators and panels. 2. Maintains
radiator and panel temperature to exactly offset the heat loss thereby eliminating "cold 70." 3. Conserves fuel by positively preventing overheating. 4. Prevents creeping
noises from pipes because temperature change is'so gradual.
6 SlAV
V
The diagram illustrates the general operation. The circulator (C) is running
continuously, circulating the water
through the by-pass from return back
through the supply line. The water in
boiler is kept at a predetermined tem
perature based on the Radiator Emis
sion rate for which the system is
designed. When heat is required the
Temperature Controller or Thermostat
(depending upon type of Hoffman
system used) causes the control valve
(V) to open, allowing the return water
to pass through the boiler and the
hotter boiler water mixes with water
passing through the Hoffman orifice, in the by-pass line from the return, to raise the
temperature of water entering the supply line. When the heat demand has been satis
fied the control valve (V) closes and normal circulation through the by-pass pipe con
tinues. The mixing of the water, already somewhat cooled from continuous circulation,
with the high temperature boiler water eliminates the "slugs" of extremely hot water so
common with forced hot water systems. There is positively no overheating and the
temperature is raised so gradually that a comfortable heat is always available \yith ap
parently no change in the heating system.
The two types of Hoff
man Hot Water- Con trolled Heat differ only
in the manner of control. The Circulator, Control
Valve and Union Orifice
are furnished with both systems.
1. Outdoor Thermal Control System--This System is
controlled by means of the Hoffman Patented Temperature Controller illustrated above. Capillary tubing is connected to a temperature bulb located on the exterior of the building and
another capillary tubing connected to a temperature bulb lo
cated in the supply line of the System. Variations in temper atures of the outdoor weather and the circulating water are
immediately transmitted through this Controller to the Control Valve. This System very completely controls the supplying of the exact amount of
heat necessary to offset the actual heat loss. Made in nine regular pipe sizes from
1 in. to 6 in. with a maximum capacity of 4,460,000 Btu.
2. Indoor Thermostat Control System--Thermostat, located in that part of the building which is to determine the heat requirements for the entire System, operates the Control Valve through the Control Panel illustrated be low. This allows the circulating water temperature to be increased according
_ to the demand of the thermostat and will supply the heat required uniformly and gradually. This System is naturally less expensive than the Outdoor Con
trol type. Available in 1 in., in. and in. sizes with a max imum capacity of 275,000 Btu.
Hoffman Circulator
Design and Operating in formation is available upon request.
1215