1208 CHAPTER 50 1957 Guide ment, and the local power rate. It is also influenced by human factors such as operation of equipment only during the hottest weather, opening windows at night9, and difference in preferred indoor temperatures. Never theless, it is important that lending agencies and prospective buyers of equipment be given a reasonably accurate estimate'of the operating cost during normal summer weather and under usual operating conditions. Adjustments can then be made for any special conditions anticipated. The -approximate electrical power inputs for the various motorized components in mechanical cycle air conditioners are shown in Table 1. Power cost per hour can be estimated by multiplying the estimated power per ton, the cooling capacity in tons and the cost per kilowatt-hour. Thus the estimated cost per hour for a 3-ton air conditioner cooled with city water will be 1.1 kw X 3 tons X the power rate. It is essential to use the cor rect step of the utility residential rate structure to get a good estimate. The basis of the method used10 requires the use of a table of the estimated Table 2. Estimated Annual Hours of Operation for Properly Sized Equipment in Typical Cities during Normal Cooling Season City Hours City Hours Atlanta, Ga....... Boston, Mass__ Chicago, 111..... Cleveland, Ohio Dallas, Texas... Fresno. Calif-- 750 Jacksonville, Fla................. 1600 200 Minneapolis, Minn.............. 350 400 New Orleans, La................. 1500 450 New York, N. Y................. 350 1400 St. Louis, Mo...................... 1000 900 Washington, D.C................ 800 annual hours of operation for properly sized equipment in typical cities See Table 2. The values in Table 2 have been substantiated by utility records of actual performance in several major cities when the average indoor temperature is maintained at 80 F. Lowindoor temperatures increase operating cost as do weather conditions above normal. Water usage is another important factor with water-cooled equipment. Various manufacturers have published water usage data for their equip ment at varying summer water temperatures. Representative water consumption values are given in Table 3. For a given application the power rate and water rate may be obtained from the local utilities. Since the average power requirement depends on the particular equipment used and the condensing method, values ob tained from the manufacturer should be used in preference to those given in Table 1. If the evaporator fan cycles with the compressor, the power requirement as found from Table 1 also represents the total power requirement for air cooled condenser applications. For continuous fan operation the number of hours of compressor operation should be subtracted from the number of hours in the cooling season to obtain the extra hours of fan operation. This value may then be used with the appropriate, value of power consumption and power cost for the fan motor only, to find the added power cost for continuous fan operation and the result should then be added to the power cost during compressor operation. For water-cooled condenser applications the water cost, as determined from the operating hours, water rate and manufacturer's data on equip Residential Summer Air Conditioning 1209 ment water usage, is added to the power cost to obtain the estimated total operating cost. Another method has been developed using cooling degree days above 70 F as a criterion but tabulated values of cooling degree days for various localities are not available.11 Approximate values can be obtained from degree day maps.12-13 The daily range of temperatures for various local ities are also required with this.method.14 It is important that the method used in estimating operating cost be consistent with the method used in calculating the heat gain of the structure. EFFECTS ON FUTURE HOUSE DESIGN Air conditioning, like automatic heating, has brought about improved practice in residential construction, particularly in those regions where cool ing is of primary importance. Although it is true that construction practices which reduce the heating load also reduce the cooling load, there are certain Table 3. Water Usage for Water-Cooled Equipment Summer Water Temperature, Normal Extremes F Gallons Per (Hour) (Ton) Summer Water Temperature Normal Extremes F Gallons Per (Hour) (Ton) 3455 75 58 3960 80 70 4465 85 88 70 50 considerations which are unique in their effect upon the cooling load. Special attention must be paid to window orientation and means of shading the windows. South windows may be shaded by awnings or roof overhangs, but it is not practicable to shade large window areas having an east or west orientation except by exterior solar screening of some type. The use of insulation in the walls and ceiling of the residence will reduce the cooling load appreciably. In addition, attention should be paid to adequate ventila tion of the attic. Double-glazed and weatherstripped windows, heat-absorb ing glass, planned shade tree locations, and light colored exterior wall and roof surfaces, also help to reduce the cooling load. REFERENCES 1 Analogue Computer Analysis of Residential Cooling Loads, by T. N. Willcox, C. T. Oergel, S. G. Reque, C. M. toeLaer and W. R. Brisken (ASHVE Transactions, Vol.60,1954, p.505). 7 Cooling a Small Residence with a Two-Horsepower Mechanical Condensing Unit, by Hi T. Gilkey, D. R. Bahnfleth and R. W. Roose, (ASHVE Transactions, Vol. 59, 1953, p. 283). 1 Application Engineering Standard for Year-Round Residental Air Conditioning, 6-10, Air Conditioning and Refrigeration Institute, 1955). * Summer Air Conditioning, Manual No. 11 (National Warm Air Healing and Air Conditioning Association, 1955). 5 Continuous Air Circulation, Manual No. 6 (National Warm Atr Heating and Air Conditioning Association, 1955). * Comparative Performances of Two Warm Air Perimeter Systems and Three Convection Systems, by M. E. Childs, R. W. Roose, H. T. Gilkey and S. Konzo (University of Illinois, Engineering Experiment Station Bulletin 403,1942). 7 Cooling a Small Residence Using a Perimeter-Loop Duct System, by D. R.