Document wq9kMKaJzEqb6LmpDM4vY7Y0B
Pumps
Branches
Atlanta
Boston Philadelphia
Goulds Pumps,
PUMP MAKERS SINCE 1848
Main Office and Works SENECA PALLS New York
Inc.
Branches
Chicago Tulsa
Pittsburgh Houston
Goulds Pumps have been made for every service for more than three-quarters of a century and have an established reputation for reliable service, economy in operation, and conservative rating. Bulletins on power pumps give complete specifications of the
standard types as follows:
No. 100. Double-Acting, Single Cylinder Piston Pumps.
No. 101. Single-Acting Triplex Plunger Pumps, Outside-Guided Type.
No. 103. Single-Acting Triplex Plunger Pumps, Large Capacity ana High
Pressure Types.
No. 104. Double-Acting Triplex Piston Pumps, Vertical Type.
No. 10S. Single Stage, Single Side Suction Centrifugal Pumps.
No. 106. Vacuum and Stuff Pumps.
No. 107. Deep Well Triplex Pumps.
No. 108. Deep Well Working Heads
and Cylinders
No. 110. Single Stage,
Double Suc
tion Centrifu
gal Pumps.
No. 111. Centrifugal
Sump Pumps
No. 112. Hanay Data
on Power
Pumping.
No. 113. Power Rotary
Pumps.
No. 115. Double-Acting Duplex
Goulds Double Suction
and Triplex Plunger t
Centrifugal Pump
Pumps, Horizontal Type
No. 116. Single-Acting Triplex
Pressure Pumps.
No. 118. Centrifugal Fire Pumps.
No. 119. Single Stage, Single Suction Centrifugal Pumps, Enclosed Impeller
GOULDS CENTRIFUGAL cavnurucM. nw oat* crect
"i`-"
PUMPS
No. 120. Multi-Stage Centrifugal Pumps for General Service.
No. 122. Centrifugal Pump Data. No. 124. Installation--Operation--Inspection, Goulds Centrifugal Pumps. No. 125. Single Stage, Double Suction Centrifugal Pumps.
Pump Data
Several units of interest to heating engineers and architects are shown here accompanied by data on capac ity, speed, efficiency which will assist them in choosing the right Goulds pump for the service desired.
Goulds Double Suction Centrifugal Pumps are the results of over 12 years of research and progressive
development and are of exceptionally high efficiences.
CASING.--Close grained iron, divided horizontally, the two castings bolted together. The lower half of the bearing housings
are cast integral with the lower half of casing. Casing is provided with air cocks, and with openings for priming and draining.
IMPELLER: Cast iron, accurately machined and balanced. BEARINGS: Ring oiling type with sphi cast iron shells lined with babbit, supported in horizontally divided housings
securely locked against rotation or
lateral motion. Sheila are removable
Table of Capacities for Goulds Centrifugal Pumps
without disturbing rotating element.-----------------------------------------------------------------------------------------------------------
THRUST BEARINGS: All pumps are provided with a self-align Figure Pump
Pipe Sizes
Approx. Capacity Gals, per Min.
Standard Pulleys
ing double-acting ball thrust bearing, running in an on bath, which takes care of any unbalanced thrust due
No. Discharge Suction Mini Maxi Diameter Face
In. - In. mum mum In.
In.
t Approx
Domestic Shipping Weight
Lb.
to uneven wear of sealing surfaces. SHAFT: Special alloy steel, heat
treated, accurately machined to
to 12^STUFFING BOX: Of ertra long
3065
f5 6 8
10
5
6 . 400
800
8
8 1020
6
.8
600 1300
10
10 1325
8
10 1000 2700 12
12 2100
12 2000 4400 12
3300
design with brass water seal ring and water seal piping.
GLANDS: The glands are split horizontally, permitting the gland to be removed arid affording maximum
space for repacking. They are ad justed by swing bolts.
CASING WEARING RINGS: Casing is equipped with bronxe wear ing rings, which can be renewed as re
quired, thus keeping the clearances to a minimum.
IMPELLER WEARING RINGS.
3075 3085
5 6 8
2 3 14
)5
16
l8 12 13
4 16
5 6 8
2 3 4
5 6 8
2 3 4
6
6 400 900
8 600 1500
10 1100 2900
3 50 325
4 150 350
5 250 750
6 400 1000
8 800 1700
10 1300 3000
3 50 250
4 200
450
5 400 800
8 500 2000
8 10
12 5 6 8 10
12 12 6 6
10 12
8 1275
10 1605;.-
12 2525'
5 600 6 950
8 1270 10 1520
12 2400
15 3425
6 1020 8 1120
10 1585 12 2900
Wearing rings on bronze impellers fWeight includes either bedplate and coupling for direct connected drive, or bedplate,
can be furnished as an extra.
pulley, pulley shaft, coupling and two pedestal bearings for belt drive.
470
Goulds Pumps, Inc.
Pumps
FLEXIBLE COUPLING: A flexible coupling of the pin-and-buffer type is provided to connect the pump to prime mover or belt pulley shaft.
BED PLA TE: Pump and prime mover are mounted on a rugged cast iron bedplate of neat design, with a drip canal around the four sides.
Goulds "Pyramid" Double-Acting Piston Pump (Fig. 1678) is especially adapted for handling Condensation of Steam Heating Systems and for General Water Supply, Mine Service and Hot Water Pumping. Built in a single iron casting embodying the base, cylinder, bearings and one cylinder head, with the cylinder fitted with a renewable cast bronze lining and the piston fibrous packed, this pump is of strong and rigid construction.
Goulds Pyramid Piston Pump
Dimensions, Speeds, Displacements. Goulds "Pyramid" Pump Ratings Based on Pumping Cold Water.
Weight Lb. 1
Pulleys Tight and Loose In.
Geared
Horse Power at Catalog Rating Horse Power for Vacuum Service tN o. So. Ft. Heat ing Radiation
Suction In.
1 Discharge 1 In.
Stroke Displ. per Rev. of Crank Shaft. Gal.
Pistons
| Q
Usual Speed and
Dis placement per Min.
Rev. Gl.
Size Pipe
,
2V< 4 .130 39 5 .50 .50 700 IV, 1V4 5 to 1 8x2V7 170
2V< 5 .245 41 10 1.00 .50 1450 l'/2 I'A 5 to 1 I5x2</2 295
3V 5 .465 39 18 1.50 1.00 2600 2
2 5 to 1 15x3 340
4V, 5 .741 38 28 3.00 1.00 4000 2'h i'h 5 to 1 16x4 525
5'/. 6 1.316 38 50 5.00 1.50 7000 3
3 5 to f 20x4 680
fFigures based on the condensation of one-third of a pound of steam per square foot of radiating surface per hour, which is a good average condition.
Goulds Double-Acting Piston Vacuum Pump (Fig. 1049) has a displacement of 10,200 gal. to 81,000 gal. per hr. The waterways are so con structed that the valves at both ends of the cylinder are always submerged. The frame is of cast iron in one piece bolted to the cylinder, supporting the bearings and crosshead guides. These pumps are designed for Suction Box on Paper Machines, Vacuum Pans, Surface Condensers, and Vacuum System of Steam Heating.
Gallons
Displaced ment
per Min.
Goulds Vacuum Pump--Dimensions and Displacements
Pistons
Di&m. Stroke In. In.
Displace ment
1 Rev. of Crank Shaft
Vacuum Steam Heating Systems
H. P.
*Sq. Ft. of
Required Radiation
R. P.M.
Sizes of Pipes
Suction In.
Dis
charge In.
170 265 385 '
525 700
1000 >350
8 10
12 14 14 16 18
10 4.28 gal.
10 6.73 " 10 9.72 " 10 13.22 " 14 18.51 " 16 27.62 **
16 39.31 "
3
5 5 m 10 10 15
24500 36000 55000
75500 100000
144000 194500
40
40 40
40 38 37 35
55 55
55 66 66 88
10 10
Figures based on the condensation of one-third of a pound of steam per square foot of radiating surface per hour, which is a good average condition.
The Goulds Sump Pump (Fig. 3029) is a standardized outfit built in one size. Ratings for this size are given below. When the sump is full the float rises and actuates the switch which in turn starts the motor. When sump is drained, the float falls and the motor is stopped. Electric current is used only when pump is running and the pump is always submerged ready to start work instantly.
Ratings--Fig. 3029 Sump Pump
Gals, per Min.. 10 15 20 25 30 35 Head in Ft....... 24 22** - 20 18 16 13
12 I5_. 20 25 30
15 14 13 11
8
471
Geared
4 to 1 4 to I 4 to 1 4 to 1 4 to 1 4 to 1 4 to 1
Single Pulley
In.
30x4 30x5 30x5 30x5 36x6 36x6 42x8
Goulds Sump Pump