PRINCIPLES OF GUARDINC
greater in diameter than the pulley, fas tened to the side of the pulley on which there is insufficient clearance
Composition or laminated wood pulleys (unless constructed with waterproof glue) should not be used where the pulleys an continuously subjected to moisture. Pulleys subject to corrosive action should be con structed of corrosion-resistant materials, such as wood.
Pulleys should be inspected frequently for cracks in the arms and rims. If cracks are found or if a piece of the run is broken off, the pulley should be removed from service immediately. Split pulleys should be in spected to determine that bolts holding the segments together ore tight Pulleys per manently out of service should be removed from the shaft and stored.
Like other power transmission equip ment pulleys should be kept in proper align ment, and those operating at run speeds in
fig. 22-9. Troueh guards for shafting over or under bench machines.
Courtety Amencon Standard* Association "Safely Cede for Fewer Presses '* Bill.
such as those on power presses, on which the point of contact between the belt and the wheel is more than 7 ft above die floor or working platform, should be guarded by an enclosure at least to a point 7 ft above the floor or working platform If the top of such a pulley is 7 ft or less above die floor, the pulley should be enclosed (Fig 22-11) Expanded metal or mesh and 20 gauge sheet metal is usually used.
The distance between one pulley and an other pulley or hanger, except in die case of tight and loose pulleys, should be slightly greater than the width of the belt This provision prevents the belt from becoming wedged between the hanger and die pulley or between two pulleys if the belt should slip off one of the pulleys and further, pre vents the belt from pulling down the hne shafting
If it is impossible to space pulleys farther apart than die width of the belt, a guard
will prevent the belt from becoming wedged
if it should slip off the pulley. This guard
may be a circular plate or flange 4 in.
Fig. 22-10. Inclined and vertical belts should be guarded as shown. Where it is necessary to fasten the guard to the floor, 6-in. clearance should be allowed for easy cleaning of the floor. The guard supports should be securely fastened to the floor.
2-20