A-C MOTOR CONTROL CENTERS-UNITROL 245 1--SINGLE PHASE TRANSFORMER--(See Note) 0 VA Rating 200 300 500 750 Price 60 Cycles Type A, B&C $162. 173. 179. 185. Space Required Width Height Depth Inches Inches Inches 20 14 10 20 14 10 20 14 10 20 14 10 Space Factor 1 1 1 1 1000 191. 20 14 10 1 1500 201. 20 14 10 1 2000 215. 20 14 10 1 3000 234. 20 14 10 1 OPTIONAL Recommended Size of Primary Circuit Breaker Trip Amps. 220 440 Volts Volts 15 15 15 15 15 15 15 15 15 15 15 15 15 15 20 15 FEATURES 2-THREE PHASE TRANSFORMERS VA Rating 6000 9000 15000 20000 25000 30000 37500 45000 50000 Price 60 Cycles Space Required Type A, B & C $580. 629. 779. 887. 959. 1053. 1247. 1376. 1517. Width Inches 20 20 20 ... ... ... ... ... ... Height Inches 28 28 28 ... ... ... ... ... ... Depth Inches 20 20 20 ... ... ... ... ... -- Space Factor 2 2 2 3 3 3 3 4 4 Recommended Size of Primary Circuit Breaker Trip Amps. 220 440 Volts Volts 20 15 40 20 50 30 70 40 100 50 100 50 150 70 200 100 225 100 5000 7500 10000 15000 361. 20 14 20 1 30 15 408. 20 14 20 1 50 25 525. 20 14 20 1 , 70 30 674. 20 28 20 2 ' 90 50 25000 931. 20 28 20 2 150 90 NOTE--When used as common control transformer adding Electrical Inter lock on Disconnect Device is recommended. 0 Single phase transformers--240 or 480 volts two wire primary, 115 volts two wire or 115/230 volts 3 wire secondary. Three phase transformers--440 volts or 550 volts primary, 120/208 volts secondary. Q Transformers from 2000 VA size and up to 25000 VA will be mounted in bottom unit space of sections only because of weight. 0 Lighting panelboard prices apply to types A-B-C--Price does not include wiring to terminal boards--incoming connections only included as lugs on mains. 0 Transformers requiring primary protection such as 2 pole fusible disconnect or circuit breaker--Select from 9804 or 9808. 3-LIGHTING PANELBOARDS-SAFETYBREAKER TYPE 115/230 V., 3 Phase 3 Wire or 3 Phase 4 Wire No. of ' Single Pole Circuits 6 12 18 24 30 Price $143. 262. 298. 335. 372. Space Required Width Inches 20 20 20 20 20 Height Inches 9'/3 or 14 18% or 14 18% or 28 28 28 Depth Inches 10 10 10 10 10 Space Factor 1 1 2 2 2 NOTE--15 to 50 amps in single pole--15-70 amps in 2 pole. 2 Pole may be substituted for 2-single pole. 3 mo IIS 0^30 =8C^o02 335o=<>= c2 o^o30 hho Qso3m3O2 PcO--i o o o 30 Price Additions Applying CO Item to Description NEMA Size "U m Unitrol <2 S Types 1 2 34 5 -n O OQ CONTROLLER >-n= 4 All Start-Stop Pushbutton in door................................................... $22. $22. $22. $22. $22. 20 5 All Run-Off-Automatic 3 Position Pilot Switch in Door.......................... 22. 22. 22. 22. 22. != i 6 All Indicating Light Mounted in Door--Includes Auxiliary Contact on > 30 Contactor if Required............................................................ 27. 27. 27. 27. 27. ---H O 7 All Forward-Reverse-Stop Pushbuttons in Door Bui. 9824-9828.............. 45. 45. 45. 45. 45. 2 8 All High-Low-Stop Pushbuttons in Door Bui. 9852-9862-9857-9866.......... 45. 45. 45. 45. 45. CO PANEL EQUIPMENT 9 All Control Circuit Transformer, 60 Cy. with Fused or Unfused Secondary.......................................................................... 27. 38. 56. 68. 77. O 10 Class 1 A Extra Auxiliary Contacts Norm. Open or Norm. Closed--Each 11. 11. a. 11. 33. B Extra Auxiliary Contacts Norm. Open or Norm. Closed--Each 21. 21. 21. 21. 43. C Extra Auxiliary Contacts Norm. Open or Norm. Closed--Each 11 Class II 27. 27. 27. 27. 49. go2 B Extra Auxiliary Contacts Norm. Open or Norm. Closed--Each 23. 23. 23. 23. 47. 12 C Extra Auxiliary Contacts Norm. Open or Norm. Closed--Each 29. 29. 29. .29 53. All Auxiliary Contact for Fusible Motor Circuit Switch (Recommended 2 Co when separate control is used).................................... ........... 20. 20. 20. 20. 33. Ss 13 All Wiring to Common Control Ci rcuit Transformer or for Separate Control r^j ;m Circuit, per Starter Unit (Recommend adding Electrical Interlock on Disconnect Device)............................................................... 10. 10. 10. 10. 10. 14 All Fused Control Circuit (One or Two Fuses). Recommended where Separate Control or Single Control Transformer for Entire Center is Used (0-30 Amp.)............................................................. 22. 22. 22. 22. 22. 15 Class 1 A Control Relay Max. 4 Pole (One per Unit)..................................... 51. 51. 51. ;i. 51. B Control Relay Max. 4 Pole (One per Unit)..................................... 80. 80. 80. 80. 80. C Control Relay Max. 4 Pole (One per Unit)..................................... 115. 115. 115. 115. 115. 16 Class II < zc B Control Relay Max. 4 Pole (One per Unit)..................................... 88. 88. 88. 88. 88. 30 m C Control Relay Max. 4 Pole (One per Unit)...................... 123. 123. 123. 123. 123. o 5 17 All 3 Coil Overload Relay in Place of 2 Coil........................................ 4. 4. 4. 4. 40. 0033 18 All Omit 2 Coil Overload Relay....................................................... 12. 20. 50. 80. 140. o NEMA size 1 will accommodate 2 extra auxiliary contact units, either N.O., N.C. or combination N.O. and N.C. types. Where one N.0. and one N.C. auxiliary contact it required a combination type is used with both contacts on the same side of the line. NEMA sizes 2, 3, 4 and 5 will accommodate 3 extra auxiliary contacts, either N.O. or N.C. >-< DISCOUNT SCHEDULE ICD-2 Continued next page -CUTLER-HAMMER 245 a. L