Document wq0OM3LMOnyv0G2R7DnxMELLB

Documents in EPA Docket OPTS 62035 PCB (Fires) *6 * ** *9 **11 *12 Toxicity of Soot from PCB Transformer Fires Ambient Water Quality Criteria for 2,3,7,8-TCDD Final Report on Industrial Hygiene Assessment of PCB Exposure of GSA Switchgear Operators - Johns Hopkins 9/1/81-10/1/82 Summary of Regional Data on PCB transformer fires Preliminary Study and Cost Effectiveness Analysis of Alternative Regulations for Indoor PCB Transformers - Putnam, Hayes & Bartlett 2/84 Substitutes forPCB's for use in indoor electrical transforers - PEDCo 1/84 *8 letter to David Dull from Equitable Life Assurance Society of the US 19 Putnam, Hayes & Bartlett, Inc. (PHB) w/BOMA 21 PHB w/Boston Edison 22 PHB w/Commonwealth Edison 23 PHB w/Dow Corning Corporation 25 PHB w/Factory Mutual Eng. Res. 27 PHB w/IT Corp, 30 PHB w/Kansas (gas & Electric Corp '* 32 PHB w/Met. Elect. Test Co., Inc. 34 PHB W/Pacific Gas & Electric 35 PHB w/RTE Corp. 3? PHB w/Southern IN Gas & Elect 42 PHB w/Southern IN Gas 6 Elect 43 PHB w/St. of CA, Dept, of General Services 46 PHB w/Travelers Co. 47 PHB w/ NIOSH - Boston Area PCB Transformer incidents 48 PHB w/EPA Region I - Boston Area PCB Transformer incidents 49 PHB/EPA - PCB Coordinator - PCB Transformer alternatives 51 .PHB w/West and Hansen Engineers 52 PHB w/Westinghouse - Alternatives 55 Summaries of German articles concerning transformer explosions 56 Summary of 10/3/83 meeting on cleanup of PCB transformer fire at First National Bank Building (Chicago) *54 PCB Capacitor Explosion in Finland - Versar, Inc. 58 Cases study of contamination i PCBs in feed - Anonymous 59 Sunnnary of PCB air sampling results - One Market Plaza - Anon 8/15/83 7? Summary of PCB airsampling results for PCBs and TCDGs at One Market Plaza - Anon 9/12/83 61 Cleanup after San Francisco Explosion - Bartlett, et al 62 Downtown dioxin danger - Burks 63 Formation of PCDFs and FCDDs from pyrolysis of chlorobenzenes - Buser 1979 64 Formation of PCDFs from the pyrolysis of individual PCB isomers - Buser 1979 65 Formation of PCDFs from the pyrolysis of PCBs - Buser 1978 77 Toxicology - The Basic Sciences of Poisons - Casarett & Doull, pp 23-25 66 Mechanistic aspects of the thermal formation of halogenated organic compounds including PCDFs - Cloudhry & Hutzinger 1982 j *67 State-of-Art reviews PCDDs and PCDFs in Utility PCB Fluid - EPRI 1983 68 Hochgiftiges Clophen spritzte aus den Trafos - Folx 1983 69 City crisis began after fire ended (Binghampton) - Geiman 1983 ! 70 Tests show PCB danger unlikely at Chimes Bldgs - Heath 1983 71 Formation of PCDF during a fire accident in capacitors containing PCBs - Jansson et al 1982 NEV 036929 72 100 PCBs leaks reported in downtown San Francisco - Melnick 1983 73 PCDF formation from PCB mixture by heat and oxygen - Morita et al 1978 *74 Comparative toxicity of PCBs & Dibenzofurans in rats - Oishi et al 1977 *75 PCDD and PCDFs and other polychlorinated polynuclear aromatics formed during incineration and PCB fires - Rappe, et al 1983 *76 PCDDs, PCDFs fi other PCPNAs formed during PCB fires - Rappe, et al 1982 *77 Degradation o f PCBs in electrical equipment - RTE Corporation 1982 78 Contamination of an office building in Binghamton, NY... - Schechter 1983 79 Big PG s E explosion - SF highrise shut * Smith 1983 80 Analysis for 2,3,7,8-tetrachlorodibenzofuran & 2,3,7,8-tetrachlorodibenzo- p-dioxin in a soot sample from a transformer explosion in Binghamton, NY Smith, et al 19B2 *81 Interim guidelines for acceptable exposure levels in office settings contaminated with PCB PCB combustion products - California Department of Health -Gravitz, et al 1983 82 Analysis of Binghamton soot sample for TCDF and TCDD - Smith, et al 1981 83 Analysis of 2,3,7,8 TCDF and 2,3,7,8 TCDD in soot sample from transformer explosion in. Binghamton - Smith,'et al 1981 84 Background of Binghamton, NY - DQH 1981 85 Determination of PCDF in soot samples.,.. - Smith, et al 1982 86 Determination of TCDFs and TCDDs in air.... - Smith, et al 1983 88 Determinationof Tetra-hexa CDFs and tetra-CDDs in air samples from.,.. Binghamton... - Smith, et al 1983 *88 Revised risk assessment of Binghamton State Office Building - Kim Hawley 1983 *89 Comparisons fo chemical and biological data on soot samples from Binghamton Eadon et al 1982 *90 The Binghamton State Office Building clean-up* a progress report update . NY state office of General Services 1983 92 Investigation - Determination of toxic compounds in sprayed-on ceilings insulators: sampling & analysis of PCBs, PCDDs fi PCDFs - VERSAR 1983 93 Investigation of contamination remaining in Binghamton State Office Building following preliminary cleanup - VERSAR 1982 96 Exposure Assessment t Fires involving PCB transformers - VERSAR 1983 rev. 1984 97 Development of Flanvnability Criteria for Transformer Dielectric fluids Department of Energy 3/80 *95 Environmental Assessment of PCBs in the Atmosphere - EPA 1977 7? The Carinogen Assessment Group'b Risk Assessment on 2,4,5-T, silvex and TCDD - 9/80 77 Workers returning to PCB skyscraper - Wegars 1983 * CMA has document ** CMA has executive summary NEV 036930