Document wo9JqRmYJ64oDgwoxwbQdddQ

HIE No. 30-C-l tMAY, 1949) AFRICAN gas BOILERS \EMPIRE and STANTDfci^Ac^w*^o0^ \ TYPE 1-GA, 2-GA, 4-GA v . A.I.A. FILE No. 30 C -l (MAY, 1949) Ame Rican - <$iand&vd First in heating ... first in plumbing 12842 '/ "EMPIRE" FOR BEAUTY The Empire Boiler is the logical choice for beautiful beating equipment that blends ' moniously with any basement decorative scheu.e. Within its lustrous, colorful jacket are hidden all the efficient, automatic controls essential to perfect beating. Where both beauty and effi ciency are desirable, the Empire provides the utmost in appearance as well as service. 1-0A STANDARD 1-GA-E. 2-0A-E EMPIRE "STANDARD" FOR UTILITY When appearance of the heating plant r secondary consideration, the Standard Boilei .a recommended for dependable, automatic heating service. 11 has the same sensitive controls as the Empire. It has every feature that assures the utmost in safe, automatic operation. 4-OA STANDARD Smart Modern Jackets in Attractive Colors Empire Boilers bring new beauty to the modern basement. Their smartly designed jackets, in richly beautiful Canyon Two-Tone Red, completely conceals all controls. Only the striking metal name plate, shown here, and the face of the water gauge appear on the handsome jacket. The Empire blends harmoniously with any decorative plan. This name plate is found only on the boiler that is a masterpiece of engineering and designing . . . your assur ance of efficiency, dependability and econ- Perfected Design Both the Empire and Standard Boilers have been designed by gas experts -- by engineers who are thoroughly familiar with this fuel l its application to home heating equipment. .,o single feature of these boilers is untried or un proved. In the laboratory and in the field the II Empire and Standard have demonstrated their sound principles that result in economy and efficiency of operation. They are quality from top to bottom -- inside and out! I Precision Controls In both the Empire and Standard Bo:' -s the desired room temperature is maintau--d without work or worry -- thanks to their fine quality, precision controls. The exclusive Thermotor Throttling Valve operates from the thermostat. This valve gradually increases or reduces the gas consumption as the desired temperature of water in the boiler is reached, using only as much gas as needed. Overheating and underheating are prevented and safety assured by the special Thermotor Throtf g Valve. With either the Empire or the Stana_.J Boiler you can enjoy to the utmost the de lightful comfort of radiator heating and its effortless operation with gas fuel. 12843 These Quality Boilers Comply with Natiouul t A TRIUMPH OF GOOD ENGINEERING -- .. _ ----------------- ---------------- ,... ________________ __ . - .,:i^ .'wa^gsBK-'w-.--t ^sm t. Flub Connection -- Designed to provide vertical flue connection through lop pond of jacket. Vertical draft hood i furnished. 2. Camopt -- Heavy coat iron aet in puity-fiUwf groove, forming perfect gaa tight joint. 3. Insulation --Tliick aslKSloe insulation all aidca effectively provenU excess heat Iimi from boiler. 4. Cleanout Openino -- Providea eaay arena v cleaning floe aurfacea of sections. 5. Pin Tvpb Cait Iron iSrction -- The moat vlfectivc type of trust iron heat obaorhioc surface. Rapidly iiiiU eiliciently absorbs tho Kent from the rising columns of hot gases and tmnafers this heat to the water within the sections. Hi;rnkr-- Raised rih. drilled port, vjuiet in operation, Riltbon Imrnent for in.mti[ncUiml gus am optional. 7. Water Leo -- Water-filled section* entirely surround combustion chamber, even below burners. Prevent excess heat radiation to floor sod permits use of water radiators located on the now floor ae the boiler. No luisuiuent required. I, Sections Assembled -- All sections assembled - factory with carefully madiined slip nipples I heavy tie rods. 9. Return Tapping -- [<orailcd at extreme bottom in front und rear for one-Goor healing system*. 10. Thermostatic Pilot -- Readily available for ignition. Keeps gaa supply valve doeed unless pilot is burning. 11. Ventilated Control Compartment -- Keeps Controls cooL 12. Combustion Chamber Access Door -- Conveniently located for assy inspection. 13. Thermotor (>ai Valve -- Electrically oper* ated from room thermostat. Water temperature throttles gaa flow to maintain required conditions. Upper limit and manod control, as well ea Thermostatic Safety Pilot embodied in same valve. 14. Throttling Control-- Element connects gaa valve with water in boiler to provide throttled gus flow. 15. Access Door -- {.urge, for easy inspection seta flush with jacket. 16. Front Insulation--Heavy asbestos air cell, metal shielded. 17. Altitude Gauge and Thermometer -- Convenient, readable, attractive. 18. Concealed Piping -- Gaa pips concealed under jacket, gaa priestire governor furnished for installation nt rear of boiler, outside of jacket. 19. Name Plate -- 'Hits distinctive identification bears the bntl known name in healing. 20. Jacket--Handsome in appearance und easy to keep clean. Beautiful. Will enhance any recreation room or deo. For the usual residence Imuliug application. our "Regular" Equipment is used. This ncludcs the boiler and all those controls generally required except a room thermostat. Any two-wire or series 10 room thermostat may be used with "Regular" Equipment which includes: Thermotor Throttling Vulve with Thermo-lhlot (566-VYV): Water Temperature Reg ulator; Gab PressuretGovornor: Combination Altitude Gauge und Thermometer; Boiler Drain und Pitot Corks; insulated Metal Jucket; Enameled Draft Hood. FOR HOMES WITHOUT BASEMENTS Even small homes without basements, apart ments, stores, restaurants, etc., can install clean automatic gas heating, using these Gas Fired Boilers. This trim, compact, inexpensive Boiler takes so little space it can be installed in a corner of a kitchen, or even in a suitable closet. CONVENIENT PAYMENT PLAN The modern way to modernize your home heat ing is with a new Empire or Standard Boiler on easy payments. These can be simply and quickly arranged without red tape. Payments can be extended over a considerable period of time so that monthly payments will fit your budget perfectly. Ask for details on this plan now. Requirements -- Approved hv American Gas Association. CONSULT YOUR CONTRACTOR For information as to the size of the Empire or Standard Boilers needed for your requirements, as well as data on cost and installation, see your Heating Contractor. He has the expert knowledge and training to give you practical advice, and he will be glad to serve you. HEATING AND PLUMBING 12844 RATINGS AND DIMENSIONS - WATER ONLY Sm additional American-Standard litoratura--Forma No. 704 and No. 733--for mora information about <)ualit7 gas boilara for hot aratar and staam haating installations. EMPIRE BOILER TYPE 1-GA-E STANDARD BOILER TYPE 1-GA INFLOW -]Of TYPE 2-GA-E l-iol-lj RETURN B-j-t f fiur n S ** iJ'TAPPtNc/Jsl U 1t ,,Ho.l.ler ;I VWGnU.AiT. 1, Installed j Ruling i Radiation | ,n 1 W| ft it D i. : Diam lint Flue (ahm. No. of Number and Size Tappings Flow Roturn l-GA-4 1 210 < 135 M>H um 3 l l-l n l-l H l-GA-Sl 280 | 180 WK 16*f| H 1 I-U4 i-in l-CA-61 I'.ll 225 WK I9*f| >. l I-IW 1-14 Boiler No. A.G.A. WaWr Rating sqft # Inslulled Radiation sq ft C. Number and L D Diam Flue C.n No of Size Toppings Conn. Burners Flow Return J-GA-4-IC :GA-5-K J-UA-6-i: 2-GA-7-K 420 560 700 H10 270 i:m 19 W 360 144 22 \ i 5 155 15 H 25 `4 6 550 17 1 i 28 * i 6 *4 L 1 l. 2 1-2 H 1-2 4 2 1-2 H 1-2 4 2 1-24 1-2 4 1-2 4 1-2 4 2 RETURN FOR FORCED CIRC TYPE 4-GA-E ______ ' flow for i------- ) FORCED CIRC B -J U -21RETURN / Boiler No. A.G.A. Water Rating | ft Installed Rudialion *q ft l. D Mae 2-GA-4 2-GA-S 2-GA-6 2-GA-7 120 560 700 010 270 13 >4 560 164 ", 155 19 *4 55n 22 *4 <* OIS No. of < 'onn. Burners i' 2 4 1 > 2 Number and Size Toppings Flow Roturn 1-2 4 1-2 4 1-24 1-2 4 1-2 4 1-2 4 1-2 4 1-2 4 2 RETURN FOR FORCED CIRC TYPE 4-GA - r - 0 I- y FORCED CIRC \AjL. Installed Boiler Water Radia 11 C K No. Hating tion sqft sq ft Number D .. a jNo.of and Size L Diam Flue Gas Burn. Conn.j e,, Tappings Re Flow turn m:w- u-kI i-r.w- 9-K m;a-iik I-GA-13-K 980 1120 1400 1680 645 740 930 1125 5 1 9 184 37'., 544 K 20 4 to 4 o44 18 23 4 4*h 56 24 26 4 52 4 9 9 U. | 14 14 14 1 1 4 1 2-2 4 2-21, 2-2 4 2-2 4 2-2 4 2-2 4 2-2 4 t Number and Boiler No. A.G.A. Water Rating sq ft Installed Radiation aq ft L D Diam Flue Gas Conn. No. of Burners Size Tuppings Flow Return 4-GA- 9 4-GA-ll t-GA-13 1120 1400 1680 740 930 1125 29 2-5 35 2-6 42 2-6 IK iy. 14 4 2-2 4 2-2 4 4 2-2 4 2-2 4 4 2-2 4 2-2 4 * The ratings -- Installed Rodiation sq ft -- of American Gas Boilers represent the maximum net toads (150 Btu per sq ft hot water) that may be connected to the boilers. Allowances have been made in these ratings for normal piping (covered) and pick-up loads. Sufficient radiation must be installed for the requirements of the building. Ratings shown are for elevauooa up to 2,000 feet. For elevations above 2,000 feet, ratings shall be reduced at the rate of b% for each 1,000 feet above sea Level. Note: All dimensions shown are in inches. For data on regular control equipment see current American-Standard Price Book. Drilled port burners are regular equipment. Ribbon burners are optional in territories where manufactured ga9 is used. Form No. 734-- 2SM-- 5 49 HAH American ^ Standard Radiator ^ ^anitat* CORPORATION nm 'COTTnrir <- n * 12845