Document wgzzkGG4JXOQRGrGZjGMoDk54

BELL HELICOPTER TEXTRON. Engineering Laboratories Report No. 0080M-182 September 17, 1980 Page 1 of 2 To: Copies to: Subject: Mr. G. Felker Messrs. N. Blatnick, A. Carmena, E. Covington, K. Porter, G. Rodriguez, R. Scott, 0. Smith; Lab Files QUALIFICATION TEST OF METALSET A-4NA (EVALUATION OF ADHESIVE WITHOUT ASBESTOS FILLER) INTRODUCTION Reported herein are the results of the test on Metalset A-4NA two-part general purpose adhesive. This work was performed on EWA 8580-H54.07. TEST RESULTS Lap shear test specimens were tested at -67F R.T. 140F and 180F. These results are given in Table I. CONCLUSIONS The Metalset A-4NA meets the requirements of 299-947-099 and should be listed on Q.P.L. by September 30, 1980. The Metalset A-4 will be flagged inactive for future procurement. TEST SPECIMENS AND METHODS The lap shear tests were performed on Metalset A-4NA per MMM-A-132 Federal Specification. APPROVED: J. Cernosek Group Engineer Methods and Materials Lab R. D. Cathey Engineer Methods and Materials Lab BHT 01086 Report No. 0080M-182 September 17, 1980 Page 2 of 2 TABLE I LAP SHEAR STRENGTH OF METALSET A-4NA Shear at -67F Shear at R.T. Shear at Shear at 180F H* O O Average Strength 2595 2584 1503 661 Required 2500 2500 1000 none BHT 01087 Bell Helicopter TEXTRON A SuOS'd'Al* ' TeiifQ" PC INTER-OFFICE MEMO 80:KA:jk-1192 December 7, 1983 Memo to: Copies to: Subj ect: Mr. P. Montes Messrs. N. Blatnick, H. Frazier, K. Porter, G. Rodriguez QPL CHANGES, SPECIFICATION 299-947-079 AND 299-947-125 Please make the following changes to the Qualified Products List (QPL) of the subject specifications: 1. Specification 299-947-079 The following material is inactive for future procurement: Vendor P/N AF3020, a product of the 3M Company 2. Specification 299-947-125, Type I Change vendor part number on the following material: Vendor P/N EA9309, a product of Hysol; change to ven dor P/N EA9309NA, a product of Hysol. J. Cernosek Group Engineer Methods & Materials Laboratory BHT 01088 Bell Helicopter TEXTRON A Subsidiary ot Textron inc INTER-OFFICE MEMO September 28, 1987 12:AJS-ISH1293 MEMO TO: COPY TO: SUBJECT: R. Lynn C. Allen, W. George, C. McKeen, B. Steele E. Szol, R. Young REPLACEMENT OF ASBESTOS CONTAINING MATERIALS As an ongoing effort to eliminate all possible incoming sources of asbestos containing materials due to the known latent health effects, we are soliciting your help by bringing this matter to the attention of each of the respective Engineering Departments who are responsible for authorizing these materials in the various manufacturing specifications. Usage of asbestos containing material at BHTI includes such items as gasket fittings, firewall insulation, upholstery materials, chafe straps - to name a few. Aside from the obvious potential health problems associated with asbestos, many of these items are no longer available through asbestos manufacturers and vendors, or are soon to be phased out, thereby necessitating the need for alternative materials to be found. The Industrial Safety and Hygiene Department encourages all Engineering Departments to work closely with Procurement in finding suitable replacement materials and to start the process of eliminating those asbestos containing materials currently in use. Your cooperation in this matter is appreciated. If I may be of assistance in any way, please advise. Alan J. Schijf Sr. Industrial Hygienist BHT 01089